1. FUNCTIONS
- It supports electrical control or hand operation. It has functions of high guard and high
security.
- It is compatible with building door phones or access control systems.
- It can be mounted in residential or commercial buildings, hotels, warehouses, schools etc.
2. INSTALLATION
- Use the self-contained screws to install the lock body, cylinder and door holder into the door
or door frame. Reccomended at least 5 mm installation distance from lock body to door holder.
- The loading spring is adjustable with the door’s weight or door’s closer power. Adjust the
hexagonal nut with a no. 12 spanner if it locks in a big noise or cannot close.
- Deadbolts could change direction according to the open type (left or right)
- Use a NO circuit with pulse of 7 - 12 d.c. voltage and a power higher than 12 Wfor 0.5 - 3
seconds. In manual mode, by pushing the button, the electric lock unlock after 1 second.
3. CAUTION
- Unlock continuous electrify time must not exceed 3 seconds. -
For safety, please use powdery lubrificant for the cylinder.
NOTE: Please read this manual carrefully before using the product.To install please contact
a qualified control acces technician. There can be differences between schematics, due to
real life conditions, and differente accesories on the market.
4. INSTALATION / CONNECTION EXAMPLES