Politec PARVIS HYBRID SMA User manual

Technical
manual

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
2
INDEX
1
MAIN COMPONENTS
Pag. 3
2
ASSEMBLING THE CABLEPIT
Pag. 4
CABLE PIT POSITIONING
Pag. 6
3
BASE INSTALLATION ON CABLEPIT
Pag. 8
4
INSTALLATION EXAMPLES
Pag. 9
5
WIRING
Pag. 10
6
CONFIGURATION OF THE OPTICALS
Pag. 11
OPTICAL TX
Pag. 11
OPTICAL RX
Pag. 12
7
SANDOR WS SMA TX MOTHERBOARD
Pag. 13
8
SANDOR WS SMA RX MOTHERBOARD
Pag. 14
9
SETTINGS & FUNCTIONS
Pag. 15
DIP SWITCHES
Pag. 15
10
COLUMN ALIGNMENT
Pag. 19
11
CALIBRATION WITH SMA SYSTEM
Pag. 20
12
CALIBRATION WITH PARALLEL BEAMS
Pag. 21
13
ALARM SENSITIVITY ADJUSTMENT
Pag. 22
14
TECHNICAL CHARACTERISTICS
Pag. 23
Installation recommendation
Verify that the beam tower is fully watertight once the cover and end caps have been correctly filled at the
end of the installation.
Use the cable glands supplied on the tower for all cabling must pass through the lower end cap using the
cable glands supplied. The missed used of proper accessories decrease the IP grade protection of the
tower.
Avoid any type of obstruction between the transmitter and receiver.
Avoid installing the receivers beams in a position where direct sunlight, at the same angle as the receivers
beams, can enter directly into optics especially at sunset and sunrise
Do not install multiple beams where the transmitter beam can interfere with other receiver beams. It is
always better place either transmitter or receivers back to back.

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
3
2
1
3
4
5
11
9
7
8
10
6
14
11
14
13
12
1.MAIN COMPONENTS
N°
Description
1
Aluminium pole
2
Pipe IR
3
Plug
4
Lamp adapter
5
Base
6
Cablepit
7
Motherboard TX
8
Group optic TX/RX
9
Motherboard RX
10
Cover for the base
11
Battery rechargeable 3.6 V
12
Power supply 12Vdc
13
Thermostat board
14
Power supply board

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
4
2.ASSEMBLING THE CABLEPIT
1. Insert the highlighted edge into other section and fix with screws
2. Insert the third section in the same way and fix with screws.

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
5
3. Enlarge the two opposite walls of cable pit to allow the positioning of last section.
4. Insert and well fix the missing screws.

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
6
CABLE PIT POSITIONING
The placement of the cable pit for PARVIS columns, after assembling, have to be done in the following way:
cement all around the cable pit keeping the top edge of it at same level of ground.
For PARVIS columns is also possible to keep the top edge ten centimeters below the level of the ground so that
it is visible only the IR tube.
This type of placement is possible only when the cable pit is fixed into the ground and not in a concrete
pavement.

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
7
POSSIBLE CORRECTION OF THE INCORRECT POSITIONING
Placement should be perpendicular to the ground. If the base is not in perfectly at ground level, is possible to
adjust it through the insert regulation of cable pit.
On the side that must be corrected loosen the insert in order to get the right inclination.
WRONG POSITIONING
CORRECT POSITIONING BY
ADJUSTING INSERTS
EXAMPLE
OF SETTING

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
8
3.BASE INSTALLATION ON CABLEPIT
Ensure that all the cables to and from the PARVIS tower passes through the supplied cable glands inserted into
the base cap. Use the central cable gland for lightning cable.
Base cover with the cable glands and O-ring
Once the cabling is completed the base cap has to be fixed to the base with relative O-ring.

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
9
4.INSTALLATION EXAMPLES
Per un’installazione a controllo di perimetro posizionare le barriere come indicato:
Note: if you use the optical sync do not place multiple transmitters on the same line in the same
direction
4 BEAMS
Simple barrier
8 BEAMS
Single barrier
8 BEAMS
Crossed barrier

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
10
5.WIRING
220 Vac
+
-
+
-
12 Vdc
THERMOSTAT
BOARD
POWER SUPPLY
BOARD 3.6V
MOTHERBOARD
TX or RX

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
11
6.CONFIGURATION OF THE OPTICALS
OPTICAL TX
NB: The address settings as per default .
1
2
3
4
5
6
1
2
3
4
5
6
TX1
TX2
TX3
TX4
TX5
TX6
TEST LED
TAMPER
TEST
BUTTON

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
12
OPTICAL RX
1
2
3
4
5
6
1
2
3
4
5
6
RX1
RX2
RX3
RX4
RX5
RX6
NB: The address settings as per default .
TAMPER
LOW
SIGNAL
LED
TEST LED
TEST
BUTTON

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
13
7. SANDOR WS SMA TX MOTHER BOARD
N.B.: When the motherboard is supplied the LED ON will flash.
LED ON
TAMPER
BATTERY
CONNECTION
3,6 V –19 Ah

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
14
8.SANDOR WS SMA RX MOTHER BOARD
N.B.: When the motherboard is supplied by battery the TEST LED will flash
- +
LED TEST
BATTERY
CONNECTION
3,6 V –19 Ah
3,6 V
3,0 V
TAMPER
ALARM
TAMPER
SUPPLY
INTERVENTION
DELAY
ADJUSTING
BATTERY LOW (BL)
SIGNAL LOW (SL)
AND FOR REMOTE
(AND)
DIP SWITCH
ANTIMASK POUTPUT
(AMK)

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
15
9.SETTINGS & FUNCTIONS
DIP SWITCHES
The board has Dip Switches to set different functions:
4 DIP SWITCH TX
1
TEST
In ON position goes in test for alignment. The TEST LED start blinking.
2
/
Not utilized
3
BEAM ON
It puts in test all TX during alignment (DIP 1 ON). Test LED fixed ON.
4
BEAM OFF
It puts OFF all TX during alignment (DIP 1 ON). Test LED fixed ON.
ON
1
2
3
4
5
6
7
8
9
10
Ex.: Function AND 1-2 with 6 beams
10 DIP SWITCHES RX
1
AND
At least 2 optical must be interrupted to give alarm
2
AND 1-2
AND function only for 1st and 2nd beam, usefull in case of growing grass
3
BEAM 3
First 3 RX are active
4
BEAM 4
First 4 RX are active
5
BEAM 5
First 5 RX are active
6
BEAM 6
all RX are active
7
S. LOW
FOG disqualification active
8
A. CRAWL
ON - Anti crawling active. In this condition if the first beam (lower) is interrupted for
more than 2 seconds, it will generate an alarm, independently of its configuration
(i.e. AND)
9
AMK
/
10
TEST
Put in ON to activate the TEST

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
16
CONECTOR 8
1
HTR
Not utilized
2
3
ALLARME
NC Alarm relay
4
5
TAMPER
NC Tamper relay
6
7
SUPPLY
Possibility to supply the radio trasmitter with 3,0 or 3,6 V
8
CONNECTOR 4
BL
BATTERY LOW
Low battery indication (negative open collector)
SL
SIGNAL LOW
Fog disqualification (negative open collector)
AN
REMOTE
CONTROL
Giving a positive (3,6 V) the AND function is activated
AMK
ANTIMASK
Segnalazione di mascheramento data dalla chiusura al negativo di un open
collector.
10. COLUMN ALIGNMENT
For proper alignment once installed barriers orient optical groups of the transmitters and receivers each optical
groups in the direction of others. Adjusting horizontally through the manual movement, and vertically through
the front screws placed above the lenses.
Vertical adjustment
Horizontal adjustment

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
17
11. CALIBRATION WITH SMA SYSTEM
You can improve the calibration through the use of the supplied filter
1. Fold the device by following the folds preset
2. Place the filter in front of the optics TX positioning the two hooks on the pins of the fork optics to
effectively search the signal alignment with critical conditions.
Simply applying the filter only on the TX, no need to repeat the operation RX.

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
18
3. Put the DIP10 in ON on the motherboard to activate the programming mode indicated by the flashing
LED test. During this phase the LED will continue to flash.
4. Start the alignment of the barrier is on activating the transmitter optics TX TEST, pressing the dedicated
button for about 3 seconds until the TEST LED turns orange.
DIP 10
ORANGE
LED
TEST
BUTTON

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
19
5. Turn the TEST on the corresponding optics receiver by pressing the dedicated button for about 3
seconds until the TEST LED turns orange , the Buzzer and LED alignment go ON.
6. Through the TRANSMITTER lens shifts , find the maximum optical alignment based on the BUZZER
and LED (high-brightness) of alignment, the 'increase in the frequency of blinking of the LEDs and the
whistle of the corresponding BUZZER indicate better ALIGNMENT.
7. By a FULL rotation on the horizontal axis of the RECEIVER optics , you make the SCANNING of the
optical signal.
8. Rotating the optical RX find the maximum value of which corresponds to the ALIGNMENT LED
(high-brightness) FIXED and whistle CONTINUOUS of the BUZZER.
PULSANTE
DI TEST
LED
ARANCIONE

POLITEC s.r.l. | Manual PARVIS HYBRID SMA –Ver. 1.2
20
9. Exit the function by repressing the ALIGNMENT TEST button for about 3 seconds on both optics (TX-
RX) ensuring that the orange LED TEST is shown in original condition.
10.When finished, remove the shade that acts as a attenuator, with the certainty of having found the
optimum value.
Once the alignment of all the beams is finished, put in OFF the DIP 10 on the motherboard to deactivate the
programming mode indicated by the LED turns off.
For the next 30 seconds the barrier will sound continuously in case of alignment not effective or
interruption of a beam; correct the orientation of the columns so that the buzzer emits no longer any sound.
N.B.: SE IL LED DI TEST CONTINUA A LAMPEGGIARE VELOCEMENTE DURANTE IL
NORMALE FUNZIONAMENTO SIGNIFICA CHE ESISTE UNA FONTE DI DISTURBO
INFRAROSSO ( ALTRA BARRIERA, FOTOCELLULA CANCELLO, …) CHE NON
PERMETTE IL CORRETTO FUNZIONAMENTO DELLA BARRIERA.
PULSANTE
DI TEST
LED
ARANCIONE
Table of contents
Other Politec Security System manuals

Politec
Politec SANDOR DUAL SMA User manual

Politec
Politec SANDOR QUAD ESA SMA Manual

Politec
Politec ALES Series User manual

Politec
Politec NAT SENSOR User manual

Politec
Politec ALES 60 User manual

Politec
Politec PARVIS WS SMA User manual

Politec
Politec PARVIS MES SMA Manual

Politec
Politec ALES WS Manual

Politec
Politec MANA MW Manual

Politec
Politec PARVIS MES SMA Series User manual