Politec NAT SENSOR User manual

DUAL TECHNOLOGY
SENSOR
(PIR + Microwave)
Outdoor use
INSTALLATION MANUAL

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
2
INDEX
1
DESCRIPTION
Pag. 3
NAT MOTHERBOARD
Pag. 4
2
MOUNTING
Pag. 5
WALL MOUNTING
Pag. 5
WALL MOUNT WITH “L” BRACKET
Pag. 6
3
COVER AREA
Pag. 7
4
PROGRAMMING AND OPERATION
Pag. 8
5
ADDITIONAL FEATURES
Pag. 9
OPEN FIELD FUNCTION
Pag. 9
EXPOSED AREA FUNCTION
Pag. 9
IR ANTI-MASK FUNCTION
Pag. 9
MICROWAVE ANTI-MASK FUNCTION
Pag. 9
SECURITY FUNCTION
Pag. 10
6
DESCRIPTION OF NOT SETTABLE FUNCTION
Pag. 10
PET IMMUNITY SYSTEM
Pag. 10
SELF-DIAGNOSIS SYSTEM
Pag. 10
AUTO-THERMINAL SYSTEM
Pag. 10
AUTO-ENVIRONMENTAL SYSTEM
Pag. 10
7
APPLICATION
Pag. 11
8
PIR LIMITER
Pag. 13
MOUNTING
Pag. 15
9
TECHNICAL SPECIFICATION
Pag. 16

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
3
1. DESCRIPTION
Dual Technology Sensor (PIR + Microwave).
AND operation in the prevention of "false alarms".
IP65 (indoor and outdoor).
Mount directly to the wall or by "L" bracket.
Sensibility adjustable PIR with angular aperture of about 6 °.
Microwave K-band 24 GHz.
IR range adjustable from 0 to 12m.
MW range adjustable from 0 to 12m.
Function and output ANTI-MASKING for infrared and microwave.
RF immunity up to 2Ghz.
Pet Immunity.
Small size (135mm x 33mm x 40mm)
Processing digital signals of PIR and MW.
Temperature Autocompensation.
Environmental Autocompensation.
EXPOSED AREA function.
Operativity Self scanning of PIR technology.
Operativity Self scanning of MW technology.
Tamper output combined anti- removal and anti-tear.
Autolettura e compensazione digitale dell’alimentazione

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
4
NAT MOTHERBOARD
1
POWER SUPPLY
10-16 Vcc –GND
Pay attention to the
polarity.
2
ANTI-MASK
(anti open collector
negative)
Negative always
opens in the event of
masking.
3
OPEN FIELD
(Positive input)
Connect the positive
signal + increases
the MW sensitivity
4
TAMPER
(N.C. tamper
output)
It opens in case of
sensor tampering.
5
ALARM
(N.C. alarm output)
It opens in case of
detection MW+IR.
6
TAMPER
BUTTONS
(anti-removal and
anti-tear)
If they get open give
the opening of N.C.
7
DIP SWITCHES
System
configuration.
8
TRIMMER MW
rotating in clockwise
increases the range
(sensibility) of MW.
9
TRIMMER IR
rotating in clockwise
increases the range
(sensibility) of IR.
10
RED LED
(ALARM)
lit up when there is a
general alarm, if
enabled.
11
YELLOW LED
(PIR)
lit up when there is a
PIR alarm, if
enabled.
12
BLUE LED
(MW)
lit up when there is a
Microwave alarm, if
enabled.
13
MICROWAVE
24GHZ
Detection sensor
MW.
14
PYROELECTRIC
SENSOR
Detection sensor IR.
4
5
1
2
3
6
7
9
8
10
11
12
13
14
+
GND

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
5
2. MOUNTING
The mounting of the NAT can occur in two modes or directly to the wall through the plate or "L"
through the mounting bracket angular.
WALL MOUNTING
1. Insert the shielded cable alarm in the fixing plate;
2. Fix the plate at wall;
3. Drill hole in the rubber nut and slide inside the cable;
4. Screw the base on the plate;
5. Fix the NAT motherboard on the support base and connect wires;
6. After the wiring and operation test close NAT sure that the seals and the O-rings are present and not
damaged to ensure the integrity of the product.
1
2
3
4
5
6

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
6
WALL MOUNT WITH “L” BRACKET
1. Insert the shielded alarm cable into the slots of the bracket angle and fasten it to the wall;
2. pass the cable through the mounting plate;
3. fix the plate to the fastening bracket angle;
4. Drill hole in the rubber nut and slide inside the cable;
5. Screw the base on the plate;
6. Fix the NAT motherboard on the support base and connect wires;
7. After the wiring and operation test close (7) NAT sure that the seals and the O-rings are present and not
damaged to ensure the integrity of the product.
1
2
3
4
5
6
7

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
7
3. COVERAGE AREA
SIDE VIEW
VIEW FROM ABOVE
NB: the system can also detect the areas underlying the sensor Nat adjusting the range (sensitivity) of the
two technologies (see below).
NB: the detecting area can change of some meters depending on the installation height of sensor and
surrounding environment.

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
8
4. PROGRAMMIN AND OPERATION
Install the sensor Nat between 2 and 3 meters in height from the floor concerned following the
instructions on page 4. Connect the power supply according to polarity (10-16Vdc) and connect the
outputs Alarm, Tamper and Anti-Mask in central according to their usage requirements.
1
2
+/GND
Power supply of NAT 10/16Vdc.
3
ANTI-
MASK
Negative open collector. Opens in
the event of masking.
4
LR
Aumento sensibilità microonda
se fornito un positivo
5
6
TMP
N.C. Tamper output. It opens in
case of sensor tampering.
7
8
ALARM
N.C. Alarm output. It opens in
case of detection MW+IR.
POWER LED ON FOR DETECTION TEST
Turn on the dipswitch number 4 for the
functionality of the LEDs detection.
1
2
3
4
ON
NB: power on for the duration of about 30
seconds if the DIP4 of the LEDs is activated you
will see an alternate flashing of these, to stabilize
the system. Term of flashes you can proceed with
the following settings.
PIR RANGE (SENSITIVITY) 1-12m
REGULATION TRIMMER: Adjust the PIR
range through the trimmer, implementing with
crossing test. Submitting ORANGE LED will
help to verify the detection of the passage in
different areas (exp. 0m, 4m, 7m, 12m). Test the
goodness of the coverage of the affected areas, by
adjusting the MW.
MW RANGE
(SENSITIVITY) 1-12m
REGULATION
TRIMMER: Adjust the
microwave range through
the trimmer, implementing
with crossing test.
Submitting GREEN LED
will help to verify the
detection of the passage in
different areas (exp. 0m, 4m,
7m, 12m). Test the goodness
of the coverage of the
affected areas, by adjusting
the PIR.
1
2
3
4
5 6
7
8

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
9
5. ADDITIONAL FEATURES
OPEN FIELD FUNCTION
By applying a positive to TERMINAL 4 it will increase the microwave sensitivity for "a open field
applications"
In this way, the implemented algorithm takes advantage of the absence of walls and windows allowing the
adjustment at a great distance (12 meters).
N.B.: Usethis function only in case of installation "in the open field" (see example 2 on p. 10); perform
the microwave sensitivity settings by checking the maximum range.
EXPOSED AREA FUNCTION
Leaving DIPSWITCH 1 in position OFF, the sensor is set for an outdoor installation with no shelter (canopies,
arcade, …) and so directly exposed to strong atmospheric agents (rain, snow, …).
With this feature activated, the system if necessary self performs the function “ENVIRONMENTAL
COMPENSATION”, adjusting its own detecting parameters, avoiding false alarms.
1
2
3
4
ON
IR ANTI-MASK FUNCTION
Turn the dipswitch number 2 for the functionality ANTI-MASK. Activating this function when an object is
placed in front of the sensor to blind it and make it ineffective, an active infrared system checks for the
presence of these in 3 seconds and gives an output signal through dedicated. The anti-mask microwave
verification of the presence of an object check in 20 seconds the presence of an object and gives an output
dedicated.
N.B.: If DIP 2 (anti-mask) and 4 (LED) are activated when it comes in a stealth mode, led blinking green-
orange alert the opening of the contact ANTI-MASK.
WARNING: When activated the DIP 2 before leaving the installation spot, you MUST close the sensor NAT
and you MUST power down and power up the entire system.
1
2
3
4
ON
MICROWAVE ANTI-MASK FUNCTION
If DIPSWITCH 2 is in position ON, you can enable the MICROWAVE ANTI-MASK FUNCTION
positioning the DIPSWITCH 1 in ON.
1
2
3
4
ON
NB: if DIP1 ON function
EXPOSED AREA disabled.
NB: if DIP1 ON function
EXPOSED AREA disabled.

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
10
SECURITY FUNCTION
Turn on the dipswitch number 3 functionality SECURITY. Activating this function if the MW sensor provides
at least 7 distinct surveys in 30 seconds, the alarm signal from a system independently of the PIR sensor
readings. Dually the IR sensor provides at least 4 separate surveys in 30 seconds, the system by an alarm
signal regardless of the sensor readings MW.
1
2
3
4
ON
When the test and programming are ended turn off the LED settings provide to secure the cover.
6. DESCRIPTION OF NOT SETTABLE FUNCTION
PET IMMUNITY SYSTEM
The system of pet immunity is able to discriminate the small animals up to a maximum of 10kg and not to
give an alarm signal. In the case of animals such as dogs and cats perform function tests.
SELF-DIAGNOSIS SYSTEM
The system will periodically check every 50sec about the functionality of the microwave and PIR system. In
case of Malfunction of one of the two detection equipment, this is signaled by the flashing of the LED
dedicated (GREEN and ORANGE for MW for IR), steadily. In this condition the system excludes the
operation of the technology is not working and the detection will continue to be present in the OR mode.
AUTO-THERMAL SYSTEM
The system detects the temperature of the surrounding environment through a dedicated sensor and modify
the detection parameters of the IR sensor in order to adapt to extreme environmental conditions.
AUTO-ENVIRONMENTAL SYSTEM
The system locates in the case of heavy rains and snowfall an environmental condition "different" after about
20 seconds and is able to adapt the system to the detection threshold by changing the parameters of both
technologies for the duration of the event.

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
11
7. APPLICATION
The sensor can be commonly used for the protection of facades using the bracket to "L", and thanks to the new
system of AUTO-ENVIRONMENTAL is able to reduce to zero the possibility of "false alarms". The
installation MUST be carried out at height between 2 and 3m by adjusting the range and sensitivity of the two
technologies (MW + IR).
Example 3
“Wide
detection
area”
installation
Example 1
“Curtain” for
windows or
doors

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
12
Example 4
"Back to back" installation
N.B.: INSTALL THE TWO SENSORS AT LEAST AT 20cm OF DISTANCE ONE FROM OTHER.
Example 3
"Double"
installation
N.B.: INSTALL
THE TWO
SENSORS AT
LEAST AT 15m
OF DISTANCE
ONE FROM
OTHER.

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
13
8.PIR LIMITER
If the NAT sensor is applied along a wall, it is possible that the PIR detects an area of none interest that can
generate more or less important reflections and false detections depending on the type of material present.
In order to obtain a more precise and safe area of detection it is possible to apply the PIR LIMITER supplied
which limits the angle of view of the sensor.
In this way, the sensor detects only interested area.
LEFT SIDE SENSOR
LIMITED

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
14
RIGHT SIDE SENSOR
LIMITED

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
15
MOUNTING
1. INSERT THE PIR LIMITER INTO THE DEDICATED SIDE TO HIDE THE DESIRED HALF.
1. PUSH THE LIMITER DOWN TO THE BOTTOM.
2. YOU CAN REMOVE THE DEVICE BY HANDLE WITH THE SCREWDRIVER

Politec S.r.l. | Installation manual NAT SENSOR –Ver. 1.10.1
16
8. TECHNICAL SPECIFICATION
Max range detection IR
Adjustable 1-12m
Max range detection MW
Adjustable 1-12m
MW Frequency
24.125Ghz
Angle IR coverage
80° vertical –6° horizontal
Angle MW coverage
80° vertical –30° horizontal
Power supply
10 –16 Vdc
Absorption on alarm
42mA
Absorption standby
40mA
Alarm Output
N.C.
Tamper Output
N.C.
Max range detection IR
Open collector -
Stand-by input
INPUT +
Operating Temperature
-20° +65° C
Dimensions
135mm x 33mm x 40mm
Weight
150gr
Mounting brackets
TOTAL WARRANTY 2 YEARS
Other manuals for NAT SENSOR
1
Table of contents
Other Politec Security System manuals

Politec
Politec MANA MW Manual

Politec
Politec ALES Series User manual

Politec
Politec ALES WS Manual

Politec
Politec SANDOR QUAD ESA SMA Manual

Politec
Politec PARVIS MES SMA Manual

Politec
Politec SANDOR DUAL SMA User manual

Politec
Politec ALES 60 User manual

Politec
Politec PARVIS MES SMA Series User manual

Politec
Politec PARVIS HYBRID SMA User manual

Politec
Politec PARVIS WS SMA User manual