9
Poolex Platinium
Test conditions 90 120 155
Air (1) 26°C
Water (2) 26°C
INVERTER MODE
Heating power (kW) 12,2~2,78 15,1~3,47 20,93~5,23
Consumption (kW) 1,79~0,20 2,22~0,261 3,22~0,46
COP (Coeff. of performance) 13,3~6,8 13,3~6,8 11,37~6,50
Air (1) 26°C
Water (2) 26°C
SILENCE MODE
Heating power (kW) 8,8~2,78 10,6~3,47 14,65~5,23
Consumption (kW) 1,11~0,209 1,34~0,261 1,77~0,46
COP (Coeff. of performance) 13,3~7,9 13,3~7,9 11,37~8,29
Air (1) 15°C
Water (2) 26°C
INVERTER MODE
Heating power (kW) 9,03~2,09 12,1~2,80 15,50~3,88
Consumption (kW) 1,86~0,28 2,50~0,40 3,39~0,57
COP (Coeff. of performance) 7,30~4,83 7,30~4,80 6,80~4,57
Air (1) 15°C
Water (2) 26°C
SILENCE MODE
Heating power (kW) 6,37~2,09 8,40~2,80 10,85~3,88
Consumption (kW) 1,15~0,286 1,53~0,379 1,86~0,57
COP (Coeff. of performance) 7,30~5,50 7,30~5,50 6,80~5,83
Air (1) 35°C
Water (2) 27°C
Cooling capacity (kW) 5,01~2,83 6,48~4,00 10,85~5,03
Consumption (kW) 1,06~0,51 2,03~0,87 2,58~1,05
Avg, EER (Energy Efciency Ratio) 4,71~3,49 4,72~3,49 4,77~3,56
Maximum power (kW) 3,2 4,0 4,9
Maximum current (A) 14 18 22
Electricity supply 220~240V / 50Hz
Protection IPX4
Heating temperature range 15°C~40°C
Cooling temperature range 8°C~28°C
Operating temperature range -10°C~43°C
Unit dimensions (mm) Ø 928 x 896
Unit weight (kg) 59 65 75
Sound pressure level at 1 m (dBA) (3) 40~48 41~50 42~52
Sound pressure level at 10 m (dBA) (3) 21~29 23~31 24~32
Hydraulic connection (mm) PVC 50mm
Heat exchanger PVC tank and titanium heating coil
Min. / Max. water ow rate (m³/h) 3,3 / 8,5 4,4 / 10,3 5,2 / 12,5
Compressor Mitsubishi Mitsubishi Mitsubishi
Compressor type Twin Rotary Twin Rotary Twin Rotary
Refrigerant R32
Load loss (mCE) 1,1 1,1 1,1
Max, pool volume (m3) (4) ≤60 ≤75 ≤95
Remote control Wired LED monitor screen
Mode Heating / Cooling / Silent
2.3 Technical specications
2. Description
The technical specications of our heat pumps are provided for information purposes only. We reserve the right to make changes without prior notice.
1 Ambient air temperature
2 Initial water temperature
3Noise at 1 m, at 4 m and at 10 m in accordance with Directives EN ISO 3741 and EN ISO 354
4Calculated for an in-ground private swimming pool covered with a bubble cover.