POP UP EIGER 500 User manual

INSTRUCTION MANUAL
FOR EIGERTOWER
+44 (0)1244 833 933 info@popupproducts.co.uk popupproducts.co.uk
EIGER 500
DOUBLE & SINGLE WIDTH 3T
INSTRUCTION MANUAL EN 1004-2-en
(Rev.03 02-12-2022)

CONTENTS
CONTENTS
INTRODUCTION
KNOW YOUR EIGERTOWER
KNOW YOUR EIGERTOWER’S COMPONENTS
KNOW YOUR KIT LIST AND SPECIFICATIONS
SAFETY DOS AND DON’TS - ALWAYS
SAFETY DOS AND DON’TS - NEVER
BEFORE YOU START
GETTING STARTED
EIGER 500 4.2M DW - ASSEMBLY
10 POINT PRE-USE SAFETY CHECKLIST
REGISTRATIONS
INSTRUCTION MANUAL
FOR EIGER 500 DOUBLE & SINGLE WIDTH 3T
11
12
15
1
2
3
4
6
8
9
10
14
EIGER 500 3.7M SW - ASSEMBLY13

Visit PASMA and HSE for further
reference.
Page 2
INTRODUCTION
EIGERTOWER is a versatile and high quality mobile access tower providing one work platform for one person used
throughout the building and construction industry for both indoor and outdoor access solutions, where a stable
and secure platform is required. Ideal for maintenance and installation work or short term access. It is designed
in accordance with the latest testing and quality standards. EIGERTOWER complies with BS EN 1004 -1 : 2020 and
WAHR with vertical ladder access and designed for Class 3 loadings. Platform heights between 2.2m & 12.2m
internal / external. Tower designation is EN1004-3-2/12-XXXD-H2.
This instruction manual is in compliance with BS EN 1004-2-en.
Verification and assessment documentation is held by POP UP Products Ltd.
Our priority is to help ensure the safe operation of our products, so please pay particular attention to the safety
tips on pages 8 & 9.
We want you to enjoy the safe and responsible use of EIGERTOWER with the minimum of fuss and this guide is
designed to get you up and running as quickly and as safely as possible.
We recommend that you read this guide prior to assembling and using your EIGERTOWER.
This instruction manual shall be available on the location of use of your EIGERTOWER.
Your EIGERTOWER shall only be used in accordance with this assembly guide without modification and
national regulations.
User training courses cannot be a substitute for instruction manuals but only complement them.
This product shall only be used according to the instruction manual.
Only original Pop Up Products EIGERTOWER components, in undamaged condition as specified in this instruction
manual, shall be used to assemble this access tower.
Pop Up Products Limited cannot accept responsibility in the event of an accident occurring because of mixing
components from different manufacturers.
Mobile access and working towers designed in accordance with EN 1004-1 are not anchor points for
personal fall arrest equipment.
Working is only permitted on a platform with complete side protection, including guardrails and toeboards.
Maximum uniformly distributed load permitted on a single platform is 275Kg.

KNOW YOUR EIGERTOWER
Page 3
PA RTS LISTING
1
2
3
7
8
9
4
5
6
11
10
14 RUN G FRAME
2HATCH PLATFORM
3DIAGONAL BRACE
4HORIZONTAL BRACE
5STABILISER
62 RUN G FRAME
7ADJUSTABLE LEG & CASTOR
82 RUNG LADDER FRAME
94 RUNG LADDER FRAME
10 STANDARD PLATFORM
11 TOEBOARD

KNOW YOUR EIGERTOWER COMPONENTS
2 FRAME CLIPS
The frame clip’s pin locates into a retaining hole in the frames to lock tower
sections together when placed one on top of the other. The pin is locked in place
by a red tab to ensure that it remains in place. From the disengaged position,
pivot the pin / tab to bring the pin horizontal. Insert the pin fully through the
4 WIND-LOCK CATCH
Disengaged Engaged
The wind lock catches comprise of a set of auto-engaging hooks at one end
of the platform and a single gravity type catch at the other. The purpose of
these devices is to prevent up-lift of the platforms in windy conditions. To
engage the auto wind lock (AWL) simply tilt the platform at the angle shown
before placing the hooks onto the rung of the end frame. Lower the
opposite end of the platform onto the opposite end frame rung and the
gravity type lock will automatically engage. Simply lift and hold the gravity
lock before tilting the platform to dis-engage the opposite AWL hooks when
removing the platform on tower disassembly.
Page 4
3 STABILISER COUPLER CLAMP
tube and set the buckle on to the hook, then close the clamp arm to lock the
The coupler clamps are used to secure the stabilisers to the tower’s vertical
Trigger
Claw
1 BRACES
Both horizontal and diagonal braces are fitted with triggered hooks at both ends.
The triggers, when operated, pull back to allow the hook to be placed over the
tubing used on the tower. Horizontal braces are also used as guardrails.
All brace hooks (Except the first base assembly braces) must be attached
to the top of the frame horizontal tube. Always double check that each hook is
positively locked onto the tubing before using the tower.
The brace hook trigger mechanisms are colour coded to show which are the
horizontal (Red) and which are the diagonal (Blue) braces.

KNOW YO UR EIGERTOWER COMPONENTS
Page 5
INSPECTION, CARE & MAINTENANCE
The toeboard, when placed on the working platform, prevents
materials and tools from falling from the tower. It consists of
folding side and end sections which are articulated via a series
of hinges.
It can be opened and fitted over the platform edges by first
unfolding the ends and sides as shown in the image to the left.
Once unfolded, place all four lower inside edges over the outer
edges of the platform.
8 TOEBOARD
Hinge
Side
End
7 ADJUSTABLE LEG AND CASTOR
The adjustable leg and castor allows for accurate positioning
of your EIGERTOWER in relation to your workplace. The leg can
be extended or retracted to allow for levelling and the brake
must be applied to prevent movement.
Do not use the adjustable legs of the wheels to increase the
height of the tower. Only use the adjustable legs to level the
tower. Make sure that the distance from the ground to the
first step does not exceed 400 mm.
Adjustment Collar
Extend
Retract
Brake OFF
ON
Engagement
Spring
9 SAFE QUICK ADVANCE GUARDRAIL PANELS
(SQ AGR)
The SQ AGR panels consist of both horizontal bracing and
diagonal bracing members in a panel which can be attached
to the tower from a safe guarded position. The horizontal
bracing elements within the panel also act as a set of ‘integral’
guardrails an as such provides automatic guarding in advance
to accessing the next level or lift of tower.
The panels are attached by means of the same type of
triggered hook as the horizontal and diagonal braces. The
triggered hooks are found at the end of the arms at the base
of the panel and another pair of hooks can be found at the
top of the panel. However these hooks are not triggered and
are simply placed over the horizontal frame tubes. They have
rubber inserts placed in the hooks to prevent the panels from
slipping on the horizontal tubes.
The triggered hooks at the base are used to positively lock the
panel in position. Place the upper hooks over the horizontal
frame tube 2m above the assembly platform and then ‘snap
the triggered hooks onto the lower horizontal frame tubes.
Keep all components clean and free from contaminants. If any part becomes contaminated with paint, acid, oils or
similar products the tower must not be used until the effected components have been cleaned and re-inspected.
Particular attention should be paid to welded joints and any moving parts, such as brace claws, adjustable leg
adjustment collars and stabiliser clamps. Ensure all safety decals are present, intact and readable.
A detailed Inspection Guide is available. To obtain a copy of this guide, please contact POP UP Products.
Threads, hinges and brace claws may be lubricated with light oil to ensure correct functionality is maintained.
Ensure oil does not contaminate climbing or walking surfaces.
All components should be stored in a dry location where they will be protected from adverse weather conditions.
When storing or transporting, keep frames upright and platforms flat. Do not stack excessively to avoid stress damage.
Please contact POP UP Products for further details on maintenance and repair of your EIGERTOWER components.

KNOW YOUR KI T LIST AND SPECIFICATIONS
Page 6
COMPONENT MATRIX AND WEIGHTS - DOUBLE WIDTH (1450mm) WH = Working Height
PH = Platform Height
PLATFORM REPOSITIONING TABLE
4.7 1 5 9
5.2 2 6 10
6.7 1 5 9 13
7.2 2 6 10 14
8.7 1 5 9 13 17
9.2 2 6 10 14 18
10.7 1 5 9 13 17 21
11.2 2 6 10 14 18 22
Tower
Platform
Height
Swap
Platform
(Rung)
Platform 1
(Rung)
Platform 2
(Rung)
Platform 3
(Rung)
Platform 4
(Rung)
Platform 5
(Rung)
Total tower weight is rounded up to nearest kilogram
DESCRIPTION 4.2 4.7 5.2 5.7 6.2 6.7 7.2 7.7 8.2 8.7 9.2 9.7 10.2 10.7 11.2 11.7 12.2 12.7 13.2 13.7 14.2
2.2 2.7 3.2 3.7 4.2 4.7 5.2 5.7 6.2 6.7 7.2 7.7 8.2 8.7 9.2 9.7 10.2 10.7 11.2 11.7 12.2
Castor 3.26 3.26 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Adjustable Leg 1.42 1.42 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
2 Rung Ladder Frame 5.40 5.40 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
2 Rung Frame 4.20 4.20 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
3 Rung Ladder Frame 7.90 7.90 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
3 Rung Frame 5.90 5.90 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0101010
4 Rung Ladder Frame 10.30 10.30 1 1 2 1 2 2 3 2 3 3 4 3 4 4 5 4 5 5 6 5 6
4 Rung Frame 7.40 7.40 1 1 2 1 2 2 3 2 3 3 4 3 4 4 5 4 5 5 6 5 6
Standard Platform 12.56 17.31 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Hatch Platform 13.25 18.00 1 2 2 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6
Horizontal Brace 1.73 2.22 6 10 10 10 10 10 10 14 14 14 14 18 18 18 18 22 22 22 22 26 26
Diagonal Brace 1.90 2.32 4 6 6 8 8 10 10 12 12 14 14 16 16 18 18 20 20 22 22 24 24
Toeboard Set 9.11 11.23 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Fixed Stabiliser 4.70 4.70 4 4 4 4 4 4 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Telescopic Stabiliser 6.44 6.44 0 0 0 0 0 0 0 4 4 4 0 0 0 4 4 4 4 4 4 4 4
Semi Jumbo Stabiliser 8.20 8.20 0 0 0 0 0 0 0 0 0 0 4 4 4 0 0 0 0 0 0 0 0
Ballast Weight 25.00 25.00 0 0 0 0 0 1 2 3 4 5 6 7 8 0 0 0 0 0 0 0 0
118 159 150 160 164 172 176 212 216 224 235 265 269 270 273 303 307 315 319 349 353
134 187 174 184 188 197 201 245 249 258 269 306 310 312 316 353 357 366 370 407 411
Total tower weight 2.5m (excl. ballast)
INTERNAL USE ONLY
Total tower weight 1.8m (excl. ballast)
UNIT
WEIGHT
1.8M (kg)
UNIT
WEIGHT
2.5M (kg)
COMPONENT SCHEDULE

KNOW YOUR KI T LIST AND SPECIFICATIONS
Page 7
COMPONENT MATRIX AND WEIGHTS - SINGLE WIDTH (850mm) WH = Working Height
PH = Platform Height
PLATFORM REPOSITIONING TABLE
4.7 1 5 9
5.2 2 6 10
6.7 1 5 9 13
7.2 2 6 10 14
8.7 1 5 9 13 17
9.2 2 6 10 14 18
10.7 1 5 9 13 17 21
11.2 2 6 10 14 18 22
Tower
Platform
Height
Swap
Platform
(Rung)
Platform 1
(Rung)
Platform 2
(Rung)
Platform 3
(Rung)
Platform 4
(Rung)
Platform 5
(Rung)
Total tower weight is rounded up to nearest kilogram
DESCRIPTION 4.2 4.7 5.2 5.7 6.2 6.7 7.2 7.7 8.2 8.7 9.2 9.7 10.2 10.7 11.2 11.7 12.2 12.7 13.2 13.7 14.2
2.2 2.7 3.2 3.7 4.2 4.7 5.2 5.7 6.2 6.7 7.2 7.7 8.2 8.7 9.2 9.7 10.2 10.7 11.2 11.7 12.2
Castor 3.26 3.26 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Adjustable Leg 1.42 1.42 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
2 Rung Ladder Frame 4.60 4.60 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
2 Rung Frame 3.20 3.20 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
3 Rung Ladder Frame 6.70 6.70 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
3 Rung Frame 4.50 4.50 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0101010
4 Rung Ladder Frame 8.70 8.70 1 1 2 1 2 2 3 2 3 3 4 3 4 4 5 4 5 5 6 5 6
4 Rung Frame 5.70 5.70 1 1 2 1 2 2 3 2 3 3 4 3 4 4 5 4 5 5 6 5 6
Hatch Platform 13.25 18.00 1 2 2 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6
Horizontal Brace 1.73 2.22 6 10 10 10 10 10 10 14 14 14 14 18 18 18 18 22 22 22 22 26 26
Diagonal Brace 1.90 2.32 4 6 6 8 8 10 10 12 12 14 14 16 16 18 18 20 20 22 22 24 24
Toeboard Set 7.40 9.52 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Fixed Stabiliser 4.70 4.70 4 4 4 4 4 4 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Telescopic Stabiliser 6.44 6.44 0 0 0 0 0 0 0 4 4 4 0 0 0 4 4 4 4 4 4 4 4
Semi Jumbo Stabiliser 8.20 8.20 0 0 0 0 0 0 0 0 0 0 4 4 4 0 0 0 0 0 0 0 0
Ballast Weight 20.00 20.00 0 0 0 0 0 0 0 1 2 3 4 5 6 0 0 0 0 0 0 0 0
99 126 129 138 141 148 151 187 190 197 208 236 239 240 243 271 274 282 285 313 317
110 145 148 158 161 169 172 215 218 226 237 273 276 277 280 316 320 328 331 367 370
Total tower weight 2.5m (excl. ballast)
INTERNAL USE ONLY
UNIT
WEIGHT
1.8M (kg)
UNIT
WEIGHT
2.5M (kg)
Total tower weight 1.8m (excl. ballast)
COMPONENT SCHEDULE

SAFETY DOS AND DON’TS - ALWAYS
Page8
1Always read and understand this guide before you begin assembly.
Always ensure that all safety requirements are met and that EIGERTOWER is the correct
access solution for the task you wish to perform.
2
Always ensure that EIGERTOWER is assembled and dismantled by a qualified, competent person.
3
Always cordon off the work area creating a zone with a radius that is 1m greater than the
total height of EIGERTOWER.
4
Always wear the correct Personal Protective Equipment for the task being performed.
Gloves, steel toecap boots, a hard hat and suitable clothing must be worn by all persons.
5
Always tie back long hair and remove items of loose jewellery.
6
Always perform a full risk assessment prior to assembling or using EIGERTOWER and abide
by your findings.
7
Always prevent access to unauthorised persons if you have no other option but to leave
EIGERTOWER unattended and if this is not possible then EIGERTOWER must be dismantled.
8
Always make tools and materials required for the assembly of your EIGERTOWER are made
available on site.
9
Always ensure you properly assess the risk/method if tools or materials are hoisted to the
platform via a rope.
10
Always access platforms from within EIGERTOWER and via the 4 rung frames positioned at
the platform’s trap door end. Keep your feet in the middle of the rungs and grip the upper
rungs with your hands.
11
Always erect EIGERTOWER on smooth level ground that is capable of supporting its own weight,
the user and any tools or materials without subsidence and free of obstructions.
12
Always use your EIGERTOWER in accordance with the instructions contained within this
assembly guide.
13
Always use your EIGERTOWER in accordance with National Regulations.
14
Always remove persons and loose materials from your EIGERTOWER before attempting to
move it.
15

SAFETY DOS AND DON’TS - NEVER
Page9
1 Never use EIGERTOWER if you don’t understand something in this guide; please contact the supplier for advice.
Never assemble, use, move or dismantle EIGERTOWER if you are tired or unwell or if you are under the
influence of alcohol or drugs.
Never use EIGERTOWER in adverse weather conditions which may endanger the user.
Never use in wind conditions of Beaufort Force 5 and above. Please be aware of the tunnel
effect caused by buildings close to each other. Dismantle the EIGERTOWER if wind reaches Beaufort 6.
Never assemble or use EIGERTOWER near overhead hazards such as power lines that are within reach of
EIGERTOWER or the user.
Never ascend or descend your EIGERTOWER if both hands are not free.
Never add banners, notice boards, etc. to EIGERTOWER or suspend weights from the tower.
Never use MITOWER if contaminated by paint, chemicals, etc.
Never overload the platforms (see component matrix page 5).
Never suspend EIGERTOWER from another structure.
Never lean from EIGERTOWER and never apply undue side force (max 200N)
Never stand on the guardrails, toe boards, boxes (or similar) to gain extra height. If the working height is
insufficient either construct EIGERTOWER to the required height or use an alternative method.
Never use damaged components in your EIGERTOWER assembly.
Never exceed a distance between platforms of 2.0m except for the first platform which can be 3.4m
from the ground.
Never use more than one working platform in your EIGERTOWER.
Never allow more than one person on a working platform.
Never use EIGERTOWER as a means to enter or exit other structures, or as a means of edge protection.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Never bridge between towers or other structures.
18
Never stand on an unguarded platform.
19
Never move the tower with people or materials on it.
20
Never lift the tower with mechanical equipment.
21
Never climb the outside of the tower.
22
4710 12 16 17 18
19 20 21 22
BEAUFORT 5
MAX

Page10
BEFORE YOU START
PREPARATION
The floor area must be clear of any obstructions including materials and debris. Check that you have all the
components necessary to construct the tower height you require. Check also each component for condition and
correct function. If any part is missing or damaged/not working correctly it must be replaced before assembling
3T (THROUGH THE TRAPD OOR) SYSTEM
The 3T method of construction has been developed to reduce the risk of an erector falling from a tower during
construction. The erector must sit on the platform with legs through the hatch and feet on the frame rungs
when attaching guardrail brace panels above the platform. This ensures the erector is always protected by a set
of guardrail brace panels.
TYING IN
You should consider tying in the tower to add stability, but this may only be carried out by a suitably
trained person.
BALLAST
Where shown in the component list, ballast must be used to stabilise against overturning. Only use solid
materials as ballast (i.e. no loose materials) and position to avoid overloading individual components. Ballast
should be supported by the base of your EIGERTOWER and securely fastened to prevent removal.
ASSEMBLY GUIDE
These instructions must always be made available to the user. If replacement copies are required, please contact
your supplier. This assembly guide is to be made available on the location of use of this EIGERTOWER.
DAMAGED COMPONENTS
Regularly inspect all components for damage. Damaged components must be quarantined so that they cannot
be used. Where safe to do so, the component can be repaired but only by a qualified repairer. If in doubt
contact your supplier for advice.
DISMANTL ING YOUR EIGERTOWER
EIGERTOWER is easily dismantled by simply reversing the erection procedure. You must, however, be protected
by guardrail braces when standing on any platform and ensure that you use the 3T method when removing
guardrail braces.
AFTER ASSEMBLY
After assembly the following information needs to be displayed on the access tower and should be clearly visible
from the ground. (e.g. on a Scafftag - www.scafftag.co.uk)
The name & contact details of the responsible person
If the tower is ready for application or not.
The load class and Uniformly Distributed Load.
If the access tower is intended for indoor use only.
The date of assembly.

GETTING STARTED
Page 11
GETTING STARTED
MOVING YOUR EIGERTOWER
MIN.
2
MAX
1%
MAX
0%
You must only move EIGERTOWER by manual effort, at a slow pace and only after fully assess-
ing the risk. Once moved, always check EIGERTOWER before using ensuring it is level within the
inclination of 1% before using it.
If EIGERTOWER is to be moved to a new location, a new level or over rough terrain, it must be
fully dismantled and rebuilt at the new location. Your EIGERTOWER is only to be moved on flat
obstacle free solid ground (0% Slope).
The Eiger 500 tower is available in two base sizes, 1450mm by a 1.8m or 2.5m platform length.
The tower will be supplied with various height frames and you must always start with the smallest size
frames first. The following instructions deal with a tower using 2 rung frames at the start, if supplied with 3 rung frames
instead of 2 rung, start with the 3 rung frames.
Where you have both 2 rung and 3 rung, you must use the 2 rung and 3 rung, you must use the 2 rung first and the 3
rung next, with (where applicable) 4 rung frames at the top. The first platform needs to be carefully positioned to
ensure that the remaining tower is constructed safely. Use the Platform Repositioning Table, found on pages 6 & 7 to
find the exact position for the platform height you are erecting.
The access tower requires a minimum of two persons to assemble it, do not attempt to assemble the tower on your
own.
STABILISERS POSITIONIN G
Stabilisers are supplied and must be fitted where specified.
For maximum effect arrange the stabilisers by positioning at an angle of 60 degrees to give a footprint as close
to that, as shown in fig. 1.
If the tower is to be positioned against a wall, the stabiliser footprint can be altered as shown in fig. 2 but only
where the heights of the wall is a minimum of two thirds the height of the top working platform.
Ensure that all four stabilisers’ feet are in contact with the ground and that the ground can support the weight
of the tower and stabilisers.
When your EIGERTOWER needs to be moved a small distance to enable you to continue your task, this can be achieved
provided the stabilisers can remain in pattern and all tools, materials and personnel are removed from the tower.
Assess the route of travel, avoiding overhead obstacles such as power lines before moving your EIGERTOWER.
You will need to raise the stabilisers so that they are no more than 25mm above the floor and properly locked.
However, if the stabilisers have to be repositioned and this reduces the footprint, your EIGERTOWER must be
reduced in height to 2m.
fig.1 fig.2
600
600
WALL

Page 12
EIGER 500 3T ASSEMBLY GUIDE
DOUBLE WIDTH 1450 TOWER 4.2M PLATFORM HEIGHT
BUILD PROCESS
STEP 1
STEP 2
STEP 3
STEP 4
Locate 4 rung frames and fit diagonal
braces as shown.
STEP 5
Locate hatch platform on the fourth
rung / 2.20m level, ensuring that the
hatch door opens outwards.
STEP 7
STEP 8
Fit next lift of 4 rung frames and attach
diagonal braces as shown.
STEP 9
If working height of tower is achieved
on this frame,locate standard platform
on eighth rung and slide across to
opposite side of tower, locate hatch
platform. This is the 4.20m level.
STEP 10
Using the 3T method install 4 horizontal
guardrail braces onto ninth and tenth
rungs to both sides of the tower.
NOTE: If building the tower beyond
the 4.20m level, continue with steps
7 to 9 until desired working height is
achieved, then follow step 10.
STEP 11
Fit the toeboard set ensuring the edges
of the toeboard overlap the platform
edges on all four edges.
THROUGH THE TRAPDOOR (3T) SYSTEM
This method of construction reduces the risk of a fall from height. You will complete
an ‘assembly / access’ platform level from which is added the ‘next lift’ of frames,
braces and platform(s) until the final working height of the tower is achieved.
Using standard components, the erector will always be protected by a set of
guardrails. By adopting the 3T method, the erector sits through the hatch of the
platform with their feet resting on the frame rungs. In this position the erector can
attach the guardrail braces at one end of the tower, access the platform and attach
the other end of the guardrail braces at the opposite end of the tower.
Insert castor / adjustable leg assemblies into
base of 2 rung ladder frame and one 2 rung
frame.
Press down firmly on the braking mechanism
to lock castors.
Fit a horizontal brace onto the vertical tube of
the 2 rung ladderframe, resting directly on
the first horizontal tube.
Ensure that the brace hook trigger faces to
the outside of the tower.
Join the 2 rung frame to the ladderframe,
ensuring that the brace hook is resting
on the opposite horizontal rung. Fit the
second brace to the horizontal tubes as
shown with hook apertures facing
downwards. Level around base of tower
using spirit level, making adjustments as
necessary to adjustable legs until the
frames have an inclination no more than
1% from the vertical. Do not use the
adjustable legs of the wheels to increase
the height of the scaffold. Only use the adjustable legs to
level the scaffold.
Ensure that the distance from the ground to the first step
does not exceed 400 mm.
STEP 6
Attach four stabilisers, one to each
corner of the tower. Place the upper
coupler of the stabiliser under the third
rung of the frame and the lower coupler
above the first rung of the frame. Adjust
the upper and lower coupler positions
until the stabiliser foot is in contact with
the ground.
Please refer to the ‘Stabilisers’ section
for details on achieving an optimum
stabiliser footprint.
Using the 3T method, position yourself
in the hatch and fit four horizontal
guardrail braces on the fifth and sixth
rungs to either side of the platform.

Page 13
EIGER 500 3T ASSEMBLY GUIDE
SINGLE WIDTH 850 TOWER 3.7M PLATFORM HEIGHT
BUILD PROCESS
STEP 1
STEP 2
STEP 3
STEP 4
STEP 5
Locate hatch platform on the third
rung / 1.70m level, ensuring that the
hatch door opens outwards.
STEP 7
STEP 8
Locate one 4 rung ladderframe and one
4 rung frame and attach four diagonal braces
as shown.
STEP 9
If working height of tower is achieved
on this frame, locate standard platform
on seventh rung and slide across to
opposite side of tower, locate hatch
platform. This is the 3.70m level.
STEP 10
Using the 3T method install 4 horizontal
guardrail braces onto eighth and ninth
rungs to both sides of the tower.
NOTE: If building the tower beyond
the 3.70m level, continue with steps
8 to 10 until desired working height is
achieved, then follow step 11.
STEP 11
Fit the toeboard set ensuring the edges
of the toeboard overlap the platform
edges on all four edges.
THROUGH THE TRAPDOOR (3T) SYSTEM
This method of construction reduces the risk of a fall from height. You will complete
an ‘assembly / access’ platform level from which is added the ‘next lift’ of frames,
braces and platform(s) until the final working height of the tower is achieved.
Using standard components, the erector will always be protected by a set of
guardrails. By adopting the 3T method, the erector sits through the hatch of the
platform with their feet resting on the frame rungs. In this position the erector can
attach the guardrail braces at one end of the tower, access the platform and attach
the other end of the guardrail braces at the opposite end of the tower.
Using the 3T method, position yourself
in the hatch and fit four horizontal
guardrail braces on the fourth and fifth
rungs to either side of the platform.
STEP 6
Attach four stabilisers, one to each
corner of the tower. Place the upper
coupler of the stabiliser under the third
rung of the frame and the lower coupler
above the first rung of the frame. Adjust
the upper and lower coupler positions
until the stabiliser foot is in contact with
the ground.
Please refer to the ‘Stabilisers’ section
for details on achieving an optimum
stabiliser footprint.
Locate one 3 rung ladderframe, one 3 rung frame
and fit four diagonal braces as shown.
Insert castor / adjustable leg assemblies into
base of 2 rung ladder frame and one 2 rung
frame.
Press down firmly on the braking mechanism
to lock castors.
Fit a horizontal brace onto the vertical tube of
the 2 rung ladderframe, resting directly on
the first horizontal tube.
Ensure that the brace hook trigger faces to
the outside of the tower.
Join the 2 rung frame to the ladderframe,
ensuring that the brace hook is resting
on the opposite horizontal rung. Fit the
second brace to the horizontal tubes as
shown with hook apertures facing
downwards. Level around base of tower
using spirit level, making adjustments as
necessary to adjustable legs until the
frames have an inclination no more than
1% from the vertical. Do not use the
adjustable legs of the wheels to increase
the height of the scaffold. Only use the adjustable legs to
level the scaffold.
Ensure that the distance from the ground to the first step
does not exceed 400 mm.

10 POINT PRE-USE SAFETY CHECKLIST
Page 14
1
2
3
4
5
6
7
8
9
10
10 POINT PRE-USE CHECKLIST FOR USERS
BEFORE USE
COMPONENTS
CASTORS
ENVIRONMENT
STABILISER COUPLER CLAMPS
GUARDRAILS
BRACE CLAWS
WINDLOCK CATCHES
FRAME CLIPS
TOE BOARDS
Ensure tower is correct, complete and level.
Check all components are free from damage.
Ensure they are locked.
No environmental changes have influenced the safe use of your tower.
Check they are secure & correctly attached.
Make sure all platforms are fully enclosed by guardrails.
Check they are locked correctly.
Make sure they are engaged.
Make sure they are engaged.
Check they are correctly positioned on the platform.

REGISTRATIONS
Page 15
ISO 9001 EN 1004
Class 3

popupproducts.co.uk
+44 (0)1244 833 933
info@popupproducts.co.uk
Table of contents