PORA PR-DTC-3000 Manual

www. pora.com
PORA ELECTRIC MACHINERY CO.,LTD.
B
E
BEB
S
ESE
T
STS
T
H
THT
E
HEH
A
N
ANA
D
NDN
T
R
TRT
U
RUR
S
USU
T
STS
Q
U
QUQ
A
UAU
L
ALA
I
LIL
T
ITI
Y
TYT
www. pora.com
PORA ELECTRIC MACHINERY CO.,LTD.
Electric Machinery Co., Ltd. www.pora.com
As to the latest information, please refer to the Website of Pora.
1. The content of this manual may be changed without prior notice, for which we request your kind understanding.
2. Be sure to read the catalog and user manual of each product before use.
3. Please accurately send a request for product specification, and check the content.
TEL: +82-31-455-8183, FAX: +82-31-457-8183
Product Purchase Inquiry
Head Office
13, LS-ro 166beon-gil, Gunpo-si, Gyeonggi-do, Korea
E-Mail
●Representative: [email protected]
●General Affairs Department: [email protected]
●Domestic: [email protected]
●International Trade-Overseas: [email protected]
Setting manual
Rev 2.3
Taper Tension Controller
PR-DTC-3000
PR-DTC-3000P


CONTENTS
Chapter 2_ Set Up & Operation
1. Simple use of the product ···············16
2. Operation Example ··················17
3. Operation Details ···················18
4. Check Up, Trial Run & Adjustment ···········19
5. Trouble shooting ···················20
Chapter 1_ Before Use
1. Control Descriptions ················· 8
2. LCD Display Descriptions ···············9
3. Specifications ····················10
4. External Connection Diagram ·············10
5. Dimensions ·····················11
6. Basic Set Up ····················12
Installation & Wiring
1. Controller Installation ················· 5
2. Arrangement of the Terminals ·············6
3. Functions of the Contacts ···············7
Taper Tension Controller
PR-DTC-3000
PR-DTC-3000P
CONTENTS
08
05
16
Feature of the Product and Safety Precautions
03
제품 이미지
제품 이미지
제품 이미지
제품 이미지


3
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-3000 Type
(Carefully read the following before using the unit)
The“PR-DTC-3000 Type”Tension Controller is a semi-automatic tension control device in the voltage controlled
OPEN-LOOP method. This method presets the starting voltage and the potential gradient of the controller
beforehand, and it calculates current voltage by deducting (Unwinding) or adding (Rewinding) the potential
gradient from or to the starting voltage per every revolution of the spindle. (A revolution detecting proximity sensor
is mounted at the spindle).
The calculated result transmits the output voltage in the range of 0~24V to the load device, that is, POWDER
CLUTCH/BRAKE.
( At the ratio setting section, you may set the number of revolutions per increase/decrease of the potential
gradient.)
Check whether there is any defect in the product and it matches with the packing list.
For the optimal performance and safe use of the product, make sure you have completely understood the
followings before use.
In particular, the product should not be employed for any other purpose than its intended use, and should not be
discretionarily remodeled.
Features of the Product
1) The tension can be controlled by simple adjustment and operation
● The tension can be controlled by setting only the variable voltage, number of revolution and starting voltage.
● A power failure compensation function of remembering the number of revolutions and output value even
when the power goes out.
2) Convenient to use
● Having adopted 3.2 inch Full Color TFT LCD, it provides diverse information such as product movements and
setup, and work progress rate.
● Value setup by operating a dial.
● Fabric data (starting voltage, number of revolutions and variable voltage) can be stored up to maximum 10
kinds. (data 0 to 9)
3) Addition of functions
● Proximity sensors of both PNP and NPN types can be used. (to be selected in SETUP)
● Weak excitation voltage can be set in accordance with the characteristics of Power Brake and Clutch.
● Basic parameters can be changed without entering SETUP mode. (start value, changed value and number of
revolutions)
4) Perfect for the following applications
● Where no precision tension control is required.
● Where the tension detector cannot be attached.
● Where manual calibration is not recommended.
● Where the system is composed of reasonably-priced components.
5) Materials applicable for the controller
● Printing, screen printing
● Packaging, filling, pasting, painting
● Cleaning, drying, fabric, sewing, coloring
Features of the product and Precautions

4 PORA ELECTRIC MACHINERY CO.,LTD.
Taper Tension Controller
Precautions for Installation
- Maintain the right vertical and horizontal angles of the product for installation.
- Install the product in a place devoid of vibration, shock, high temperature or humidity, direct sunlight, much
dust,or air containing much salt or ions.
- Do not install the product within the vicinity of inflammable gases or steam or dust.
- Wire the product as provided in the following drawings and check if all cables are properly connected.
- Ensure the earthing terminal is correctly grounded.
- Ensure the product is detached from the power supply cables or the cables with much electrical noise.
Precautions for Use
- Unwarranted operation of the controller may cause the defects of the object materials.
- Pora shall NOT be responsible for any damages to the controller caused by such operations.
Warning
For the installation and wiring of the controller, completely isolate it from the external power
supply. Failure to do so may result in an electrical shock or damage to the controller.
Precaution
Check the surrounding environment. Do not install the controller where it can be exposed to
excessive dust, conductive dust, corrosive gases, high temperature or rainy wind. It also should
not be installed in the places susceptible to vibrations or shocks. Failure to do so may result in
damages to, or malfunctioning or lowered performance of the controller.
Warning
Use anti-explosive products where there are high risks of inflammation or explosion. Failure to
do so may result in a fire or explosion. Use the anti-explosive products suitable to the given
conditions.

5
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-3000 Type
1) Controller Installation
The controller can be installed in various methods as below.
Installation & Wiring
Install the product in places which guarantee the user’s convenience,
management and maintenance.
① Firmly fasten the unit on the panel
② Please Coupled to the bracket
and tighten the screws

6 PORA ELECTRIC MACHINERY CO.,LTD.
Taper Tension Controller
2) Arrangement of the Terminals
Terminal pad
PR-DTC-3000
'(
2 3 4
789
2 3 4 45 5
1518 1417 1316
5
10 4
12
5
11
12
23
34
45
56
PR-DTC-3000P
'(
2 3 4
789
2 3 4 45 5
1518 1417 1316
5
10 4
12
5
11
12
23
34
45
56
1SPYJNJUZTFOTPS
13%/
7
4*((/%
5 5
10 4
1211
Proximity sensor connecting terminal
※ To attain the perfect compatibility with the controller, make sure to use the cylinder-type proximity sensor by Autonics.
(And also, the 24V NPN or PNP type sensor)
Due to the potential risks of malfunctioning and damages to the unit, make sure to check the above
terminals and match their respective colors.
Precaution : Check the sensor connecting terminals
- Use crimp-style terminals being equal the figure below in size.
- Be sure to fasten terminals tightly so that they would not be a cause of malfunctions.
- Do not install input/output wires through the same duct with other power lines, and do not bind them together.
- The pulse input wire to the roller shaft should be grounded using a shield wire from signal receiver.
.
NN
NN
#FDBSFGVMPG
QPXFSFMFDUSJDXJSJOH
#FDBSFGVMPG
QPXFSFMFDUSJDXJSJOH

7
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-3000 Type
The unit can be seriously damaged by the wrong connection (observe the diagram of load connection) of the power
terminal, contacts between the DC input/output wiring and power line, and the short circuit of the output line.
Before supplying power, ensure the appropriate connection between power and grounding, and the input/output wiring.
Precaution : Check power input and wiring
1) Output ON/OFF (OUT Input Terminal)
-
When the Remote Out is On, the control output is generated irrespective of [Out ON/OFF Button] on the panel.
- When the Remote Out if Off, the [Output ON/OFF Button] on the panel becomes valid, and each time the
button is pressed, the control output changes ON → OFF → ON.
2) Diameter Preset (RSD Input Terminal)
- As the initial diameter set when the Remote RSD is On is preset as the reel diameter, the measurement of the
reel diameter becomes initialized.
3) Unwind/Rewind (BWD Input Terminal)
- When the Remote BWD is On, the diameter measurement does Rewind to add diameter.
- When the Remote BWD if Off, the diameter measurement does Unwind to subtract diameter.
4) Emergency Stop (STP Input Terminal)
- When the Remote STP is On, the rate set at the STP is produced in proportion to the immediately preceding
output.
5) Calculation of the Diameter
- The unit always calculates the diameter based on the signals from the proximity switch.
- Based on the calculation, the control output adds at Rewind, and subtracts at Unwind.
0'' 0/
3FNPUFPVU
065165
0/0''4XJUDI
$POUSPMPVUQVU
0''
3) Functions of the Contacts

8 PORA ELECTRIC MACHINERY CO.,LTD.
Taper Tension Controller
1. Control Descriptions
Before Use
ltz
32.5
L
7
FRXQW
FQW
pY
(
ڪڰگ
ڮگڜڭگ
ڮۏۀۋڱ
ڞڪڰکگ
%"5"
uwu
ڨڜکڰ
4. DIAL Button
5. FUNCTION Button
3. OUT Button
2. MANU/AUTO Button
1. RESET/ESC Button
Category Descriptions
1 RESET / ESC Button
-Press long (auto/manual mode): The controller is reset to the saved initial value.
- Press once (setup mode): It operates as an ESC button, and performs the function to cancel the
settings or shift to the exit menu.
2 MANU/AUTO Button It switches between manual mode and auto mode.
3 OUT Button Every time it is pressed, output is turned on or off.
4 DIAL Button
Dial: It is used to change various values.
-Press long (manual mode): It lets the user enter the setup menu.
- Press once (setup mode): It operates as an enter button, and performs the function to select an
item or save the settings.
5 FUNCTION Button
-Press long (manual mode): It enables selection of fabric information (data 0 to 9)
- Press once (auto/manual mode): It enables setup of the starting voltage and the number of
revolutions. Whenever it is pressed, the starting voltage and the number of revolutions are
activated to configurable state.

9
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-3000 Type
12. Status
Indicator
2. LCD Display Descriptions
ltz
32.5
L
7
FRXQW
FQW
pY
(
ڪڰگ
ڮگڜڭگ
ڮۏۀۋڱ
ڞڪڰکگ
%"5"
uwu
ڨڜکڰ
1. DATA 2. EMS
4. EMS Output ratio
5. Output %
6. Output V
7. Weak excitation
voltage
8. COUNT
10. START
11. COUNT
13. MODE
9. StepV
3. SENSOR
Display Descriptions
1DATA The data (fabric information) number currently used is displayed.
2 EMS It is displayed when the controller is operated.
3 SENSOR It indicates whether the sensor mode is PNP or NPN.
4 EMS Output ratio It indicates the emergency stop rate set by the user when the controller is stopped.
5 Output % The current output value is displayed in percent.
6 Output V The current output value is displayed in volt.
7 Weak excitation voltage It is displayed when the weak excitation voltage is set (0 % or higher).
8 Number of revolutions It shows for how many revolutions the set variable voltage is applied.
9 StepV It shows the voltage changing during the set number of revolutions.
10 STA RT It shows the starting voltage of output.
11 COUNT It indicates the number of revolutions of the fabric (the axis of rotation)
12 Status Indicator It displays the ‘unwinding’ or ‘rewinding’ condition.
13 MODE It displays ‘auto mode’ or ‘manual mode’ condition.

10 PORA ELECTRIC MACHINERY CO.,LTD.
Taper Tension Controller
3. Specifications
4. External Connection Diagram
7
065
&.4
'64& 7JO
345
#8%
$POUS
PM0VUQVU
065
065
(/%
(/%
7
4*(
(/%
7
7JO
7JO
4VC0VUQVU
_7ED
4VC0VUQVU
_N"
7
(/%
N7
(/%
7JO
4FOTPS*OQVU
%JHJUBM*OQVU
1
PXFS*OQVU
_7
ED
PR-DTC-3000
22~26Vdc
PR-DTC-3000P
100~240Vac
7
065
&.4
/
-
'64& 7JO
345
#8%
$POUS
PM0VUQVU
065
065
(/%
(/%
7
4*(
(/%
7
7JO
7JO
4VC0VUQVU
_7ED
4VC0VUQVU
_N"
7
(/%
N7
(/%
7JO
4FOTPS*OQVU
%JHJUBM*OQVU
1
PXFS*OQVU
_7
BD
4.14
7"
Category Terminal DTC-3000 Specifications DTC-3000P Specifications
Input
Power + / L 22~26 VDC 100~240 VAC
- / N
External
remote
EMS -ON = Emergency stop (The set emergency stop rate output is generated.)
-OFF = General operation
OUT -ON = Output is generated and the OUT button of the operation panel is deactivated.
-OFF = The OUT button of the operation panel is activated.
RST
-Current voltage reset → It operates in parallel with the RESET button of the
operation panel.
-The current voltage is changed to the starting voltage when the input is ‘On’.
BWD -ON = Rewind, OFF= Unwind
-This switches between increase and decrease of winding pulse.
COM -External remote COM terminal
COM -External remote COM terminal
Proximity
sensor
V+
-Proximity switch/The response speed of the input pulse is 250 Hz or slower.
-PNP or NPN can be used (selected in setup)
SIG
GND
Output
Brake
and
Clutch
PP Control output for Power Clutch/Brake
About 0 ~ 24 VDC input proportional
(maximum 5 A)
Control output for Power Clutch/Brake
About 0 ~ 24 VDC 75 W (2.8 A)
PN
Voltage
output
V_OUT The voltage proportional to the output is generated between 0 and 10 VDC.
(When the output is 50.0 %, 5.0 V is generated.)
GND
Current
output
I_OUT The current proportional to the output is generated between 4 and 20 mA.
(When the output is 50.0 %, 12㎃ is generated.)
GND

11
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-3000 Type
5. Dimensions
PR-DTC-3000
PR-DTC-3000P
162
82
Cutting Size
68.6
7.2
64
145
150
70
71.2
162
82
7.2
173.8
145
150
70
68.6
181
Cutting Size

12 PORA ELECTRIC MACHINERY CO.,LTD.
Taper Tension Controller
32.5
L
7
FRXQW
FQW
pY
(
ڪڰگ
ڮگڜڭگ
ڮۏۀۋڱ
ڞڪڰکگ
%"5"
uwu
ڨڜکڰ
6. Basic Set Up
To move to ‘Menu Setup’, press the dial button long in MANU mode.
Set the items basically required for operation of the product.
Menu Setup Control Button
Menu Set Up
DIAL button
Press the dial long to enter the
setup item, and turn it to change
the set value
RESET/ESC button
Press it to move to the previous
menu
32.5
L
7
FRXQW
FQW
pY
(
ڪڰگ
ڮگڜڭگ
ڮۏۀۋڱ
ڞڪڰکگ
%"5"
uwu
ڨڜکڰ
32.5
L
7
FRXQW
FQW
pY
(
ڪڰگ
ڮگڜڭگ
ڮۏۀۋڱ
ڞڪڰکگ
%"5"
uwu
ڨڜکڰ
FUNCTION button
Press long(manual mode):
It enables selection of fabric information
(data 0 to 9)
Fabric information
(DATA 0~9)
SET UP
V
2.X
1.
SELECT DATA
2.
DATA SET
3.
USER SET
4.언어/
LANGUAGE
5.
IN/OUT CHECK
6.
DEFAULT RESET
7.
EXIT
DATA 0
ENG

13
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-3000 Type
- Turn the dial button in setup menu to move to ‘Data selection’
- Activate change of set value by pressing dial button in ‘data selection’.
Check whether there is any problem with the actual output switching among
‘control output’, ‘voltage output’, and ‘current output’ by turning the dial.
-The data value (data 0 to data 9) can be designated by turning the dial button.
-The number of the fabric to be set is selected.
1) Data Selection
2) Data Set Up
- Turn the dial button in setup menu to move to ‘Data setup’
- To move to ‘Data setup’, press the dial button.
- ‘START VOLT, COUNT, STEP VOLT’ can be set by turning the DIAL.
Rewind
1.Starting voltage :
Set the start voltage of the output. During rewinding, the output increases from the start voltage by the number of
revolutions and variable voltage, and during unwinding, the output decreases from the start voltage.
2.Number of revolutions :
It shows the voltage changing during the set number of revolutions.
3.Variable voltage :
Shows for how many revolutions the set variable voltage is applied.
■Voltage algorithm = Number of revolutions
Variable voltage
Unwind
SET UP
V
2.X
1.
SELECT DATA
2.
DATA SET
3.
USER SET
4.언어/
LANGUAGE
5.
IN/OUT CHECK
6.
DEFAULT RESET
7.
EXIT
DATA 0
ENG
SET UP
V
2.X
1.
SELECT DATA
2.
DATA SET
3.
USER SET
4.언어/
LANGUAGE
5.
IN/OUT CHECK
6.
DEFAULT RESET
7.
EXIT
DATA 0
ENG
DATA SET
1.
DATA SET
2.
COUNT
3.
STEP VOLT
4.<--
10.0
100
100
2.4V %
CNT
㎷
시작
(START)
회전수(COUNT)
변동전압(STEP VOLT)
시작
(START)
회전수(COUNT)
변동전압(STEP VOLT)
시작
(START)
회전수(COUNT)
변동전압(STEP VOLT)

14 PORA ELECTRIC MACHINERY CO.,LTD.
Taper Tension Controller
3) User setup
- Turn the dial button in setup menu to move to ‘User setup’
-To move to ‘User setup’, press the dial button.
- ‘EXCITATION, EMS RATE, SENSOR TYPE, OP. MEMORY, BRIGHTNESS, BUTTON SOUND’ can be set by
turning the DIAL.
1. Excitation voltage:
A certain weak voltage may be applied to the brake and clutch to prevent the powder from being
wadded or jammed.
2.Emergency stop rate:
When the EMS terminal is turned on, the output rate is set.
3.Sensor mode :
The proximity sensor mode is set. ( )
4.Operation mode :
It is the function which remembers the current condition. The current condition is maintained when
the power is suddenly cut off or turned off.
5.Screen brightness :
The brightness of the LCD is adjusted.
6.Button sound :
Button sound: It sets whether to use the button sound or not.
EMS example)
- If the output is 20 % and
the EMS set value is 50 %, the output when the EMS is ‘On’ is 10 %
the EMS set value is 100 %, the output when the EMS is ‘On’ is 20 %
the EMS set value is 200 %, the output when the EMS is ‘On’ is 40 %
- If the output is 80 % and
the EMS set value is 50 %, the output when the EMS is ‘On’ is 40 %
the EMS set value is 100 %, the output when the EMS is ‘On’ is 80 %
the EMS set value is 200 %, the output when the EMS is ‘On’ is 160 %
NPN PNP
SET UP
V
2.X
1.
SELECT DATA
2.
DATA SET
3.
USER SET
4.언어/
LANGUAGE
5.
IN/OUT CHECK
6.
DEFAULT RESET
7.
EXIT
DATA 0
ENG
USER SET
1.
EXCITATION
2.
EMS RATE
3.
SENSOR TYPE
4.
OP. MEMORY
5.
BRIGHTNESS
6.
BUTTON SOUND
7.<--
6.6V
27.6
%
100
%
NPN
USE
80
%
USE

15
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-3000 Type
4) LANGUAGE
-Turn the dial button in setup menu to move to ‘LANGUAGE'
-To move to ‘LANGUAGE’, press the dial button
(※ The values which can be changed will turn violet.)
- ‘Korean’ or ‘English’ can be set by turning the DIAL.
5) Input/Output checking
6) Factory initialization
- Turn the dial button in setup menu to move to ‘Input/output checking'
-To move to ‘Input/output checking’, press the dial button
- Adjust ‘Control Output’, Voltage Output’ and ‘Current Output’ using the DIAL
to see if there is any problem in the actual output.
(※ The values which can be changed will turn violet.)
- Turn the dial button in setup menu to move to ‘Factory initialization'
-To move to ‘ERASE ALL’, press the dial button
- Select ‘YES’ in ‘Execute Initialization’ using the DIAL to initialize all set data.
SET UP
V
2.X
1.
SELECT DATA
2.
DATA SET
3.
USER SET
4.언어/
LANGUAGE
5.
IN/OUT CHECK
6.
DEFAULT RESET
7.
EXIT
DATA 0
ENG
SET UP
V
2.X
1.
SELECT DATA
2.
DATA SET
3.
USER SET
4.언어/
LANGUAGE
5.
IN/OUT CHECK
6.
DEFAULT RESET
7.
EXIT
DATA 0
ENG
SET UP
V
2.X
1.
SELECT DATA
2.
DATA SET
3.
USER SET
4.언어/
LANGUAGE
5.
IN/OUT CHECK
6.
DEFAULT RESET
7.
EXIT
DATA 0
ENG
IN/OUT CHECK
1.
CONTROL OUT
2.
V OUT (0~10V)
3.
I OUT (4~20㎃)
4.<--
0.0
%
0.0
%
%
0.0
IN : OUT RST EMS BWD PLS
DEFAULT RESET
1.
ERASE ALL
2.<--
YES
All data will be
initialized! ! ! ! ! ! !

16 PORA ELECTRIC MACHINERY CO.,LTD.
Taper Tension Controller
Set Up & Operation
1. Simple use of the product
The unit can be seriously damaged by the wrong connection (observe the diagram of load connection) of the power
terminal, contacts between the DC input/output wiring and power line, and the short circuit of the output line.
Before supplying, ensure the appropriate connection between power and grounding, and the input/output wiring.
Precaution : Check power input and wiring
Manual mode
1.Press Fn button long to activate DATA and then select a number by turning the dial.
2.Press Fn button to activate Starting Voltage.
3.Set the voltage by turning the dial.
4.If the tension of the actual fabric is proper, switch to auto mode.
Auto mode
1.Observe change in the tension while the line is in progress.
2. If the tension is not proper, activate Number of Revolutions by pressing Fn button twice and then
adjust the tension by changing the number of revolutions.
3.Nullify all activations by pressing Fn button once.
Completion of the
work
1. When the work is completed, switch to manual mode and then reset it to the initial value by
pressing the RESET button long before starting the work again
2. The starting voltage and number of revolutions shall be set only once at the beginning. After
initially setting it for work, if the fabric is same as the previous one, use it from the next work
only after switching between auto and manual modes.
3. If the data number is required to be changed, press Fn button long to activate DATA, and then
change the number by turning the dial. Nullify all activations by pressing Fn button once. If the
button is not activated to violet color, there will be no change when the dial is turned.
Checking before use
1.Check the wiring conditions of all cables before applying the power to the product.
2.Check the input power (22 ~ 26 VCD or 100 ~ 240 VAC) and apply the correct power.
Voltage algorithm

17
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-3000 Type
2. Operation example
1SPYJNJUZTFOTPS
3FXJOEFS .BUFSJBM
.BYJNVN%JBNFUFS
ⱒ
*OJUJBM%JBNFUFS
ⱒ
13%5$UZQF
1PXEFS
#SBLF$MVUDI
&YUFSOBMTXJUDI
Sample setup
Check the input power (22 ~ 26 VCD or 100 ~ 240 VAC) and apply the correct power.
WARNING : Check the wiring conditions of all cables before applying the power to the product.
Voltage algorithm
1 Setup mode
-To move to ‘Setup’, press the dial button long in MANU mode.
( ※In auto mode, the screen will not be shifted to ‘Setup’ even when the dial button is pressed
long.)
1. Data saving: Press dial button and then designate the data value by turning the dial. (※ A
figure between 0 an 9 can be selected.)
2.Data setup: Enter the data value by turning the dial after pressing the dial button.
(※‘Starting voltage' and ‘number of revolutions’ can be also reset by pressing Fn button on the
main screen.)
2 Manual mode
1. Turn the dial to set the ‘starting voltage’ and ‘number of revolutions’ after pressing the dial,
and then end the setup by pressing Fn button.(※ The values which can be changed will turn
violet.)
2.Change and set the number of revolution checking the actual tension.
3 Auto mode
1.Change and set the number of revolution checking the actual tension.
2.Turn the dial to set the number of revolutions after pressing the dial, and then end the setup by
pressing Fn button.(※ The values which can be changed will turn violet.
4 Completion of the work When the work is completed, switch to manual mode and then reset it to the initial value by
pressing the RESET button long before starting the work again.

18 PORA ELECTRIC MACHINERY CO.,LTD.
Taper Tension Controller
-
When manual mode is selected, the last output value
inthe previous auto mode becomes effective as manually
controlled output and the value is displayed on the output
display window. At this time, turning the [DIAL] left or right
increases or decreases the control output.
- After the mode is switched from manual to auto, it is
converted to a value equivalent to the start voltage.
- The minimum voltage value which can be set as variable
voltage value is 1 mV, and can be set to a value lower
or higher than the current gradient with a limitation that it
should be higher than 1 mV
- The maximum number of revolution when the minimum
voltage is set is 24,000.
- If the number of revolutions exceeds 24,000, it can be
resolved by changing the value in Revolution Number
Setup below.
- The maximum range of the number of revolution which
can be set is 999.
number of revolution = 1:1, starting voltage = 0, variable voltage = 1mV setting
3. Operation Details
563/-&'5
563/3*()5
7" -6&
%*"-
065165
1)Manual adjustment of torque and the role of the dial
2)Relation between number of revolution setup and output voltage
(examples of basic setup of winding)
3)When the number of revolutions in the basic setup is changed
7
7
4FUUIFJOJUJBM(SBEJFOUWPMUBHF
DPVOU DPVOU
065165
7
7
$06/5
$06/5
(SBEJFOUWPMUBHF
DPVOU
065165
7
7
$06/5
(SBEJFOUWPMUBHF
DPVOU DPVOU
065165
This manual suits for next models
1
Table of contents
Other PORA Controllers manuals
Popular Controllers manuals by other brands

Mitsubishi Electric