Specifications:
Scanner technical parameters
Data storage: 4M, inventory model can store 30000 bar code
Wireless standard: 2.4GHZ ISM band
Interface: receiver: USB
Communication range: 100 meters (open range of visibility)
Keyboard layout: United States (default)
Light source: 650 nm visible laser
Scanning speed: 200 times per second
Decoding ability: all one dimensional bar code
Input voltage: scanner charging power supply: DC:+4.75V ~ +5.25V
Receiver: DC:+4.75V+5.25V USB
Battery: 1100Mah
Working current: sleep: 0.5MA: scan: 65MA:
Data transmission: 135MA
Working hours: >20 hours
Tips: buzzer, LED
Working temperature: 0 degrees C to 50 degrees C
Storage: -40 degrees C to 60 degrees C

Humidity: 5% to 95%
Safety regulations: EN60825-1 1, national first class laser safety standards
Electromagnetic compatibility: EN 55022, EN55024
Electrical safety: EN60950-1
Environmental protection: with the ROHS standard
Material: ABS+TPU
Net weight: 135g
System function setting
Factory Default setting
All scanners have a factory default settings, scan "Factory Default "bar
code, will make the scanner all property settings to be factory default
setting.
In the following cases you can use this bar code:
1. The scanner setting error, such as unable to read bar code.
2. You have forgotten what you did before to the scanner settings, and
do not want to be affected by the previous settings.
3.Setting the scanner to use a function that is not frequently-used, and
the use of after.
Factory Default

System function setting
Wireless function settings
Pairing setting code
When the barcode scanner and the receiver can not transmit data,
please scan this bar code.This operation will delete the original pairing
product.
Note: when the barcode scanner and the receiver Pairing , the barcode
scanner must work under the Wireless mode . (function setting please
see table below)

System function setting
Wireless function settings
Wireless mode automatic storage mode
Internal storage mode displays total storage
Clear all data upload all data and clear
Display receiving end address Display transmitter end address
Shutdown 60 seconds automatic
shutdown

System function setting
function setting
Display version Display factory date
key trigger mode Automatic continuous scanning
Open sound Turn sound off
All for Capital All for lowercase letter
Positive image recognition Reverse image recognition

System function setting
Keyboard language
American (English) French (French)
Spanish Latin America
Danish German (German)
Swedish Portuguese
Italian Dutch
Turkish Arabic

System function setting Bar code type function setting
CODE39
Open CODE39 Close CODE39
Open CODE39 Close CODE39
FULL ASCLL FULL ASCLL
Open CODE39 Close CODE39
MOD43 check MOD43 check
Open CODE39 Close CODE39
Multiple check sending check
CODE39 TAB mode Close CODE39
Multiple check

System function setting
Bar code type function setting
UPC/A/E
Open UPC-A Close UPC-A
Open UPC-A to EAN13 Close UPC-A to EAN13
Send UPC-A check code Donot send UPC-A check code
Open UPC-E Close UPC-E
Open UPC-E to UPC-A Close UPC-E to UPC-A

System function setting
Bar code type function setting
EAN13
Open EAN13 Close EAN13
Send EAN13 check code Donot send EAN13 check code
Open EAN13 to ISBN Close EAN13 to ISBN
Open EAN13 to ISSN Close EAN13 to ISSN
Open EAN13 Multiple check Close EAN13 Multiple check

System function setting
Bar code type function setting
EAN8
Open EAN8 Close EAN8
Open 2 bit additional code Open 2 bit and 5 bit
additional code
Open 5 bit additional code Close additional code
EAN8 Hidden system bit EAN8 donot hidden system bit
EAN8 send check code EAN8 donot send check code

System function setting
Bar code type function setting
CODE93
Open CODE93 Close CODE93
Open code93 Multiple check Close code93 Multiple check
Open 93 code MOD47 Close 93 code MOD47

System function setting
Bar code type function setting
CODE128
Open code128 Close code128
Open code128 Close code128
Multiple check Multiple check

System function setting
Bar code type function setting
CODABAR
Open codabar Close codabar
Open codabar Close codabar
Start stop Start stop
Open codabar Close codabar
Multiple check Multiple check

System function setting
Bar code type function setting
Cross 25 code
Open cross 25 code Close cross 25 code
Open cross 25 code Close cross 25 code
Multiple check Multiple check

System function setting
Bar code type function setting
Industrial 25 code
Open Industrial 25 code Close Industrial 25 code
Open Industrial 25 code Close Industrial 25 code
Multiple check Multiple check
Set Industrial 25 code ID for O

System function setting
Bar code type function setting
MSI code
Open MSI code Close MSI code
Open MIS Multiple check Close MIS Multiple check
Set MIS ID for S

System function setting
Bar code type function setting
Plessey code
Open Plessey code Open Plessey code
Open Plessey Close Plessey
Multiple check Multiple check
Set Plessey code
ID for T

System function setting
Bar code type function setting
CODE11 code
Open CODE11 code Close CODE11 code
Open COD11 code Close CODE11 code
Multiple check Multiple check
CODE11 C check CODE11 CK check

System function setting
Bar code type function setting
Matrix 25 code
Open Matrix 25 code Close Matrix 25 code
Set matrix 25 code
ID for Q
Post code 25 code
Open Post code 25 code Close Post code 25 code
Set Post code 25 code
ID for R