Powerline PLM100 User manual

INSTRUCTION MANUAL
PLM100 100m Laser Distance Measurer

2
Please read this instruction manual before operating
this product. Please store this instruction manual in the
carry case for future reference.
CAUTION: Class 2 Laser Product
Do not stare directly into the laser beam from apertures.
Keep out of reach of children.
Due to the electromagnetic radiation interference
to other equipment and devices please do not use
the laser distance measurer in an airplane or around
medical equipment.
Do not use in a ammable, explosive environment.
Discarded batteries or devices shall not be processed
with household garbage. Please follow related laws
and regulations.
Do not disassemble the instrument or attempt to
perform any internal servicing as this will void your
warranty. No user serviceable parts included.
Only approved and authorised service technicians can
carry out warranty repairs.
SAFETY

3
Please ensure the following items are included with your
laser distance measurer.
If anything is missing please contact your retailer.
Powerline PLM100
Carry strap Batteries
Carry case
ITEM CHECKLIST
READ
UNIT
OFF
CLEA R

4
READ
UNIT
OFF
CLEA R
PRODUCT OVERVIEW
LCD screen
Laser emitter
Control panel

5
READ
UNIT
OFF
CLEA R
Plus
Area / volume
Benchmark
Power off / clear
Read (laser emission on)
Minus
Unit reset
Data storage
Pythagoras
Backlight
CONTROL PANEL

6
DISPLAY SCREEN
ft
im
ft
im
ft
im
ft
im
Min
Max
Maximum display
Minimum display
Measurement mode
Measurement
Measurement unit
Auxiliary display
Lord measurement display
Laser emission on Battery level
Data storage

7
USING YOUR DISTANCE MEASURER
Power Supply
‣The Powerline PLM100 is supplied with three AAA
alkaline batteries.
‣To replace batteries remove the battery door at the back
of the device. Place batteries according to polarity and
replace battery door.
‣For infrequent use please take out the battery to avoid
corrosion to the body of the device.
‣To turn the measurer on, press the read button.
The instrument and laser will start simultaneously
and begin measurement.
‣To turn o press and hold the off / clear button for 3 seconds.
‣The device will shut o automatically after 150 seconds
without use.
Unit Setting
To reset the current unit of measurement press the unit
button. The unit default is 0.000m.
Operation
Length Area Volume
0.000m 0.000m20.000m3
0.00m 0.00m20.00m3
0.0in0 0.00ft20.00ft3
0.00ft0 0.00ft20.00ft3
Optional units as below:

8
Backlight Setting
Press and hold the backlight button to turn
the backlight on or off.
Measurement Benchmark Setting
To switch between front and back benchmark press
the benchmark button.
Measurement
Single Measurement
‣Press the read button. The laser will be emitted.
‣Re-press the read button for a single distance measurement.
Results will be displayed on the display screen.
Continuous Measurement
‣Press the and hold the read button. Minimum and
maximum results will be displayed on the display screen.
‣Press the read button to exit continuous measurement.
Area Measurement
‣Press the area / volume button. A rectangle will appear
on the display screen with one edge flashing. Follow the
instructions displayed on the screen as below:
‣Press the read button to measure the first edge (length).
‣Press the read button to measure the second edge (width).
‣Area will be calculated automatically with results shown
on the display screen.
‣Press the off / clear button to clear measurement.

9
Volumetric Measurement
‣Press the area / volume button twice. A cube will appear
on the display screen with one edge flashing. Follow the
instructions displayed on the screen as below:
‣Press the read button to measure the first edge (length).
‣Press the read button to measure the second edge (width).
‣Press the read button to measure the third edge (height).
‣Volume will be calculated automatically with results shown
on the display screen.
‣Press the off / clear button to clear measurement.
Pythagoras Measurement
To calculate the unilateral distance of a triangle pythagorean
mode can be used. When taking measurements of the triangle
ensure the length of the right side is shorter than the length of
the hypotenuse. If not, the instrument will display an error signal.
To ensure the accuracy of measurement, take measurements
from the same starting point of the first order hypotenuse.
Then follow with the measurement of the right side.
Please follow the instructions according to the method
required. (See diagrams on page 10 - 11 to determine the
appropriate method).

10
2. Press the pythagoras button twice to enter pythagorean
mode. A triangle will appear on the display screen with the
vertical side flashing. Follow the instructions displayed on
the screen as follows:
‣Press the read button to measure the length (a) of the side.
‣Press the read button to measure the length (b) of the next side.
‣Length (x) of the hypotenuse will be calculated automatically
with results shown on the display screen.
x
a
b
1. Press the pythagoras button to enter pythagorean mode.
A triangle will appear on the display screen with the
hypotenuse flashing. Follow the instructions displayed
on the screen as below:
‣Press the read button to measure the length (a) of the hypotenuse.
‣Press the read button to measure the length (b) of the side.
‣Length (x) will be calculated automatically with results
shown on the display screen.
x
a
b

11
3. Press the pythagoras button three times to enter
pythagorean mode. A triangle will appear on the display
screen with the hypotenuse flashing. Follow the instructions
displayed on the screen as below:
‣Press the pythagoras button to measure the length
(a) of the hypotenuse.
‣Press the read button to measure the length (b) of the
hypotenuse. (See diagram)
‣Press the read button to measure the length (c) of the
next hypotenuse. (See diagram)
‣Length (x) of the vertical side will be calculated
automatically with results shown on the display screen.
4. Press the pythagoras button four times to enter
pythagorean mode. A triangle will appear on the display
screen with the hypotenuse flashing. Follow the instructions
displayed on the screen as below:
‣Press the pythagoras button to measure the length (a).
‣Press the read button to measure the length (b). (See diagram)
‣Press the read button to measure the length (c). (See diagram)
‣Length (x) of the vertical side will be calculated automatically
with results shown on the display screen.
x
a
b
c
x
a
b
c

12
Adding and Subtracting Measurement
Single distance measurement can be done through adding or
subtracting to get an accumulated add or subtract operation.
‣To add two measurements together take the first reading
by pressing the read button.
‣Press the plus button. A “+” symbol will appear on the
display screen.
‣Take the second reading by pressing the read button.
The values will be added automatically with the results
shown on the display screen.
‣To subtract two measurements take the first reading
by pressing the read button.
‣Press the minus button. A “-” symbol will appear on
the display screen.
‣Take the second reading by pressing the read button.
The values will be subtracted automatically with the
results shown on the display screen.
Storage and Browsing
After a reading has been taken the data may be stored.
Press and hold the data storage button for three seconds.
The data will automatically be stored in the unit’s memory.
To view stored measurements press the data storage button.
Press the plus or minus button to browse through the data.
To remove stored data press and hold the power off / clear button.

13
Err1 Signal is too weak.
Measure target locations which are with stronger
reflecting surfaces.
Err2 Signal is too strong.
Measure target locations which are with weaker
reflecting surfaces.
Err3 Battery voltage too low.
Replace battery.
Err4 Beyond working temperature.
Carry out measurement with the meter in the specified scope.
Err5 Improper measurement in pythagorean proposition.
Re-measure and ensure the length of the hypotenuse is
longer than that of the right side.
Err6 Memory damage.
Please contact the supplier.
TROUBLE SHOOTING

14
CARE AND MAINTENANCE
‣Inaccurate measurement results may occur in harsh
environments such as strong sunlight, excessive temperature
fluctuations, weak reflective surfaces or low battery.
‣Whenever possible, store the instrument in a cool, dry
place. Do not store in high temperatures or strong
humidity for long periods of time.
‣Remove the batteries before storing the device for long
periods of time without use.
‣To remove dust clean the instrument with a damp, soft cloth.
WARRANTY
The Powerline PLM100 comes with a 6 year manufacturers warranty.
Our goods come with guarantees that cannot be excluded
under the Australian Consumer Law. You are entitled
to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable loss or
damage. You are also entitled to have the goods repaired or
replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Separate to the above Australia Consumer Law, Spot-on
oers a global warranty.
Customer Support
To assist you with any queries or technical questions
please contact the customer support line: 1300 658 338
Operates 5 days a week: 8am - 5pm (EST)

15
SPECIFICATIONS
Specications PLM100
Product code 50109
Warranty 6 Years
Accuracy ±1.5mm
Range 0.2 - 100m
Minimum unit displayed 1mm
Measurement unit options mm/in/ft
Continuous measurement function yes
Area measurement function yes
Volume measurement function yes
Add and subtract measurement function yes
Max storage 99 units
Automatic backlight yes
Buttons sound yes
Laser class 2 Red
Laser type 65nm, <1mW
Automatic laser cut off 20s
Automatic shutdown 150s
Storage temperature -20° - 60°
Working temperature 0° - 40°
Storage humidity RH85%
Battery 1.5V 3x AAA
Weight (Exc battery) 130g
Dimensions 124x54x23mm

www.spoton.com.au
Table of contents
Other Powerline Measuring Instrument manuals

Powerline
Powerline PLM40 Mk II User manual

Powerline
Powerline A3 User manual

Powerline
Powerline S4BL User manual

Powerline
Powerline S5BLG User manual

Powerline
Powerline PLM70 User manual

Powerline
Powerline 3D HYBRID User manual

Powerline
Powerline S5BL User manual

Powerline
Powerline XL2G User manual

Powerline
Powerline X2R User manual