Powerline PLM40 Mk II User manual

INSTRUCTION MANUAL
PLM40
40MLASER DISTANCE MEASURER
Mk II

2
Read the following safety instructions before attempting to operate this product.
Keep these instructions in a safe place for future reference.
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING: Read and understand
all instructions.
› Use the laser measurer only with the
specied batteries.
› Store the laser measurer out of reach of
children and other untrained persons.
Lasers are dangerous in the hands of
untrained users.
› Due to the electromagnetic radiation
interference to other equipment and
devices please do not use the laser
distance measurer in an airplane or
around medical equipment.
› Do not use in a ammable, explosive
environment.
› Discarded batteries or devices shall
not be processed with household
garbage. Please follow related laws
and regulations.
› Tool service must be performed only
by qualied repair personnel. Repairs,
service or maintenance performed by
unqualied personnel will void the
warranty. Only approved and
authorised service technicians can
carry out warranty repairs.
› Do not use optical tools such as a
telescope or transit to view the laser
beam. Serious eye injury could result.
› Do not place the laser in a position
which may cause anyone to intentionally
or unintentionally stare into the laser
beam. Serious eye injury could result.
› Do not position the laser near a
reective surface which may reect
the laser beam toward anyone’s eyes.
Serious eye injury could result.
› Do not use optical tools to view the
laser beam.
› Do not remove or deface warning
labels.
SAFETY
!
WARNING: DO NOT DISASSEMBLE THE
LASER MEASURER. There are no user
serviceable parts inside. Disassembling
the laser will void all warranties on the
product. Do not modify the product in
any way. Modifying the tool may result in
hazardous laser radiation exposure.
CAUTION: Class 2 Laser Product
› Never look into the laser beam
directly and intentionally.
› Do not use optical tools to view the
laser beam.
› Do not let children come in contact
with the laser measurer.
!

3
ITEM CHECKLIST
Powerline PLM40 Mk II Carry pouch
Carry strap Alkaline batteries
Please ensure the following items are included with your laser distance
measurer. If anything is missing please contact your retailer.

4
LCD screen
Bubble vial
Laser emitter
Control panel
PRODUCT OVERVIEW
LASER MEASURER FRONT

5
Battery compartment
Wrist strap attachment
End piece
1/4" thread for operation
on a tripod
LASER MEASURER BACK
LASER MEASURER BOTTOM

6
Addition
Area / volume
Staking out
Benchmark / Timer
Power off / clear
Read (laser emission on)
Subtraction
Data storage
Pythagoras
Unit reset / backlight
CONTROL PANEL

7
Measurement mode
Continuous measuring
Maximum display
Minimum display
Measurement
Laser emission on
Measurement unit
Battery level
Data storage
Staking-out
Power off / clear
Unit reset / backlight
DISPLAY SCREEN

8
USING YOUR LASER MEASURER
POWER SUPPLY
› The Powerline PLM40 Mk II is supplied with two 1.5v AAA alkaline batteries.
› To replace batteries remove the battery door at the back of the device.
Place batteries according to polarity and replace battery door.
› For infrequent use, please take out the battery to avoid corrosion to the body
of the device.
ON/0FF
› Press and hold the read button to turn the laser distance measurer on.
› Press and hold the off / clear button for 3 seconds to turn the unit off. The device
will shut off automatically after 150 seconds without use.
UNIT SETTING
› To reset the current unit of measurement press the unit reset / backlight button.
The unit default is 0.000m.
OPERATION
OPTIONAL UNITS
Length Area Volume
0.000m 0.000m20.000m3
0.00m 0.00m20.00m3
0.0in0 0.00ft20.00ft3
0.00ft0 0.00ft20.00ft3
0 1/16 in 0.00ft20.00ft3
0'00' 1/16" 0.00ft20.00ft3

9
BACKLIGHT SETTING
Press and hold the unit reset / backlight button to turn the backlight on or off.
REFERENCE POINT SETTING
To cycle between the benchmark reference points press the benchmark button.
There are four reference points: top, middle, bottom and end piece.
SINGLE MEASUREMENT
› Press the read button. The laser will
be emitted.
› Re-press the read button for a single
distance measurement. Results will be
displayed on the display screen.
CONTINUOUS MEASUREMENT
› Press and hold the read button. Minimum
and maximum results will be displayed on
the display screen.
› Press the read button to exit continuous
measurement.
MEASUREMENT

10
AREA MEASUREMENT
a) Press the area / volume button. A rectangle will appear on the display screen
with one edge flashing.
b) Press the read button to measure the first edge (length).
c) Press the read button to measure the second edge (width).
d) Area will be calculated automatically with results shown on the display screen.
e) Press the off / clear button to clear measurement.
VOLUME MEASUREMENT
a) Press the area / volume button twice. A cube will appear on the display screen
with one edge flashing.
b) Press the read button to measure the first edge (length).
c) Press the read button to measure the second edge (width).
d) Press the read button to measure the third edge (height).
e) Volume will be calculated automatically with results shown on the display screen.
f) Press the off / clear button to clear measurement.

11
1. Calculate the side of a right angle triangle
Press the pythagoras button to enter pythagorean mode.A triangle will appear on
the display screen with the hypotenuse flashing. Follow the instructions displayed
on the screen as follows:
a) Press the read button to measure the length (a) of the hypotenuse.
b) Press the read button to measure the length (b) of the rectangular side.
c) Length (x) will be calculated automatically with results shown on the display
screen.
a
b
X
X
PYTHAGORAS MEASUREMENT
To calculate the unilateral distance of a triangle pythagorean mode can be used.
When taking measurements of the triangle, ensure the length of the right side is
shorter than the length of the hypotenuse. If not, the instrument will display an
error signal.
To ensure the accuracy of measurement, take measurements from the same
starting point of the first order hypotenuse. Then follow with the measurement
of the right side.
Please follow the instructions according to the method required. (See diagrams on
page 11 - 13 to determine the appropriate method).

12
3. Calculate partial length of a right angle triangle
Press the pythagoras button three times to enter pythagorean mode.A triangle
will appear on the display screen with the hypotenuse flashing. Follow the
instructions displayed on the screen as follows:
a) Press the read button to measure the length (a) of the hypotenuse.
b) Press the read button to measure the length (b) of the second hypotenuse.
c) Press the read button to measure the length (c) of the rectangular side.
d) Length (x) of the vertical side will be calculated automatically with results
shown on the display screen.
2. Calculate the hypotenuse of a right angle triangle
Press the pythagoras button twice to enter pythagorean mode.A triangle
will appear on the display screen with the vertical side flashing. Follow the
instructions displayed on the screen as follows:
a) Press the read button to measure the length (a) of the rectangular side.
b) Press the read button to measure the length (b) of the next rectangular side.
c) Length (x) of the hypotenuse will be calculated automatically with results
shown on the display screen.
XX
ab

13
OTHER FUNCTIONS
DELAYED MEASUREMENT (TIMER)
a) Press the benchmark / timer button.
b) Press the addition or subtraction button to adjust the time (Minimum 3 seconds,
maximum 60 seconds).
c) Once the time has been set, press the read button.
4. Calculate the third side of a triangle
Press the pythagoras button four times to enter pythagorean mode.A triangle will
appear on the display screen with the hypotenuse flashing. Follow the instructions
displayed on the screen as follows:
a) Press the read button to measure the length (a).
b) Press the read button to measure the length (b).
c) Press the read button to measure the length (c).
d) Length (x) of the vertical side will be calculated automatically with results shown
on the display screen.
abc
X
XX

14
ADDING AND SUBTRACTING MEASUREMENT
Addition
a) Take the first reading by pressing the read button.
b) Press the addition button. A “+” symbol will appear on the display screen.
c) Take the second reading by pressing the read button. The values will be added
automatically with the results shown on the display screen.
Subtraction
a) To subtract two measurements take the first reading by pressing the read button.
b) Press the subtraction button. A “-” symbol will appear on the display screen.
c) Take the second reading by pressing the read button. The values will be subtracted
automatically with the results shown on the display screen.
STAKING-OUT FUNCTION
The staking-out function allows the user to enter a value into the unit.The unit
will then guide the user into nding the exact reference point.
a) Press and hold the area / volume / staking-out button to enter staking-out
mode.
b) Press the addition or subtraction button to enter a value. Press and hold the
addition or subtraction button to enter a larger gap.
c) Once the value has been set, press the read button. The unit will display an
arrow pointing forwards or backwards, depending on the location of the user.
Move forward or back until the unit shows the centred symbol:

15
STORAGE AND BROWSING
Save a reading
Press and hold the data storage button for three seconds.The data will automatically
be stored in the memory of the unit.
View storage
To view stored measurements, press the data storage button. Press the addition or
subtraction buttons to browse through the data.
Remove records
To remove a record, press the power off / clear button.To remove all stored data
press and hold the power off / clear button.

16
CARE AND MAINTENANCE
› Inaccurate measurement results may occur in harsh environments such as
strong sunlight, excessive temperature fluctuations, weak reflective surfaces
or low battery.
› Whenever possible, store the instrument in a cool, dry place. Do not store in
high temperatures or strong humidity for long periods of time.
› Remove the batteries before storing the device for long periods of time
without use.
› To remove dust, clean the instrument with a damp, soft cloth.

17
TROUBLE SHOOTING
ERROR CODE CAUSE & SOLUTION
ERR1 Signal is too weak.
Measure target locations that have stronger reflecting surfaces.
ERR2 Signal is too strong.
Measure target locations that have weaker reflecting surfaces.
ERR3 Battery voltage too low.
Replace battery.
ERR4 Beyond working temperature.
Carry out measurement with the meter in the specified scope.
ERR5
Improper measurement in pythagorean mode.
Re-measure and ensure the length of the hypotenuse is longer
than that of the right side.
ERR6 Memory damage.
Please contact the supplier.

18
WARRANTY
CUSTOMER SUPPORT
The Powerline PLM40 Mk II comes with a 6 year manufacturers warranty.
AUSTRALIA
"Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and
for compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a major failure."
For more information please visit consumerlaw.gov.au
NEW ZEALAND
For more information please visit consumerprotection.govt.nz
To assist you with any queries or technical questions please contact customer support
Australia: 1300 658 338
New Zealand: 0800 367 527

19
SPECIFICATIONS
Specications PLM40 Mk II
Product code 50204
Accuracy ±1.5mm
Minimum measurement range (top reference point) 0.05m
Maximum measurement range 40m
Minimum unit displayed 0.05mm
Measurement unit options m/in/ft
Continuous measurement function yes
Area measurement function yes
Volume measurement function yes
Add and subtract measurement function yes
Max storage 100 units
Automatic backlight yes
Buttons sound yes
Laser class 2 Red
Laser type 635nm, <1mW
Automatic laser cut off 20s
Automatic shutdown 150s
Storage temperature -20° - 60° C
Working temperature 0° - 40° C
Storage humidity RH85%
Battery 2x 1.5v AAA
Weight (Inc battery) 180g
Dimensions 118x54x26.5mm

www.spoton.com.au
Table of contents
Other Powerline Measuring Instrument manuals

Powerline
Powerline S5BL User manual

Powerline
Powerline PLM100 User manual

Powerline
Powerline A3 User manual

Powerline
Powerline S4BL User manual

Powerline
Powerline XL2G User manual

Powerline
Powerline S5BLG User manual

Powerline
Powerline 3D HYBRID User manual

Powerline
Powerline X2R User manual

Powerline
Powerline PLM70 User manual