powersoft DigiMod 3004PFC4 User manual

Keep this manual
for future reference
©2021 Powersoft
USER GUIDE
Digimod 3004 PFC4
DO000XYZ.00 Rev. 00

powersoft_DigimodPFC4_uguide_en
Data are subject to change without notice.
For latest update please refer to the
online version available on www.powersoft-audio.com.

Table of contents
1.Important safety instructions iii
2.Importantes instructions de sécurité iv
3.Instrucciones de seguridad importantes v
4.Importanti istruzioni di sicurezza vi
5.Regulatory information vii
6.Electrostatic Discharge (ESD) viii
7. Digimod 3004 PFC4 1
7:1.Welcome 1
7:2.Unpacking&checking for shipping damage 1
7:3.Disposal of the packing material 1
8.Thermal constraints 2
8:1.Heatsink performance 2
9.Electromagnetic Compatibility (EMC) & Safety 3
9:1.AC MAINS filter 3
9:2.Cabling 3
9:3.Ferrite cores 3
9:4.Chassis shielding 3
9:5.Mains Fuse 3
9:6.Earth connection 3
10.Mechanical drawings 4
11.Connections 5
10:1.1.Main connectors pinout 6
10:1.2.Bill of connectors 6
10:2.PL1003 pinout 8
10:3.PL3003 pinout 10
10:4.PL1000 Pinout 12
10:5.PL2000 Pinout 12
10:6.PL3000 Pinout 12
10:7.PL4000 Pinout 12
10:8.Audio path block diagram 13
10:7.1.Internal Signal Path Polarity 13
10:9.Protections 14
10:9.1.Power supply protections 14
10:9.2.Primary AC mains overcurrent protection 14
10:9.3.Primary AC mains overvoltage protection 14
10:9.4.Primary thermal protection 14
10:9.5.Amplifier protections 14
10:9.6.Secondary thermal protection 14
10:9.7.Harmful signal protections 15
10:9.8.Output short circuit 15
10:9.9.High frequency stationary loud signals 15
10:9.10.Auxiliary power protections 15
10:9.11.Control Board protection LEDs 15
10:10.LED chart 16
10:10.1.Control Board LED chart 16
10:10.2.Main Board LED chart 16
12.Evaluation Board - KT000291 17
11:1.Switch functions 17
13.Support and warranty 20
12:1.Service 20
12:2.Warranty 20
12:2.1.Return of Goods 20
12:2.2.Repair or replacement 20
12:2.3.Cost and responsibility of transport 20
12:3.Assistance 20
14.Specifications 21
| i

ii | Digimod 3004 PFC4 | User guide
Page intentionally left blank

Important safety instructions 1
This amplier module is intended to be installed inside
other devices and must be checked in the nal product. CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This unit has been engineered and manufactured to ensure your personal
safety. But IMPROPER USE CAN RESULT IN POTENTIAL ELECTRICAL SHOCK OR
FIRE HAZARD.
In order not to defeat the safeguards incorporated into this product, observe
the following basic rules for its installation, use and service. Please read these
“Important Safeguards” carefully before use.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this equipment near water.
6. Do not block any ventilation openings. Install in accordance with
Powersoft’s instructions.
7. Do not install near any heat sources such as radiators, heat regis-
ters, stoves or other apparatus that produce heat.
8. Do not defeat the safety purpose of the polarized or grounding-
type plug.
9. Only use attachments/accessories specified by Powersoft.
10. Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way, such
as power-supply cord or plug is damaged, liquid has been spilled
or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has
been dropped.
11. The apparatus shall be connected to a MAINS socket outlet with a
protective earthing connection.
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE,
DRIPPING OR SPLASHING LIQUIDS. OBJECTS FILLED WITH
LIQUIDS, SUCH AS VASES, SHOULD NOT BE PLACED ON THIS
APPARATUS.
SPEAKER TERMINALS COULD BE HAZARDOUS LIVE IF
SPEAKER BRIDGE MODE CONNECTION IS USED.
PROPER CONNECTIONS AND INSULATIONS TECHNIQUES
MUST BE ADOPTED WHEN SPEAKER BRIDGE MODE
CONNECTION IS USED.
CLASS3
WIRING
THE TRIANGLE WITH THE LIGHTNING BOLT IS USED TO ALERT
THE USER TO THE RISK OF ELECTRIC SHOCK.
CLASS3
WIRING
THE TRIANGLE WITH THE EXCLAMATION POINT IS USED TO
ALERT THE USER TO IMPORTANT OPERATING OR MAINTENANCE
INSTRUCTIONS.
THE CE-MARK INDICATES THE COMPLIANCE OF THE PRODUCT
TO ALL THE APPLICABLE EUROPEAN DIRECTIVES
SYMBOL FOR EARTH/GROUND CONNECTION.
SYMBOL FOR CONFORMITY WITH DIRECTIVE 2012/19/EC OF
THE EUROPEAN PARLIAMENT ON WASTE ELECTRICAL AND
ELECTRONIC EQUIPMENT (WEEE).
+35 OC
0 °C
0°C TO +35°C
DERATING ABOVE 35°C.
10%
90%
%10% TO 90% HUMIDITY (NON CONDENSING).
DO NOT USE THE UNIT AT ALTITUDES ABOVE 2000 M.
DO NOT USE THE UNIT IN TROPICAL ENVIRONMENT.
CLASS3
WIRING
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO
NOT ATTEMPT TO OPEN ANY PART OF THE UNIT. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
CLASS3
WIRING
CONNECTION TO THE MAINS SHALL BE DONE ONLY BY A
ELECTROTECHNICAL SKILLED PERSON ACCORDING THE
NATIONAL REQUIREMENTS OF THE COUNTRIES WHERE THE
UNIT IS SOLD.
CLASS3
WIRING
VERIFY THAT YOUR MAINS CONNECTION IS CAPABLE OF
SATISFYING THE POWER RATINGS OF THE DEVICE.
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR DAMAGES
CAUSED TO PERSONS, THINGS OR DATA DUE TO AN IMPROPER OR
MISSING GROUND CONNECTION.
CONTACT THE AUTHORIZED SERVICE CENTER FOR ORDINARY AND
EXTRAORDINARY MAINTENANCE.
IT IS ABSOLUTELY NECESSARY TO VERIFY THESE FUNDAMENTAL
REQUIREMENTS OF SAFETY AND, IN CASE OF DOUBT, REQUIRE AN
ACCURATE CHECK BY QUALIFIED PERSONNEL.
Important safety instructions | iii

Importantes instructions de sécurité 2
Ce module d’amplication est destiné à être
installé à l’intérieur d’autres dispositifs et doit
donc être contrôlé sur le produit ni. AVIS
RISQUES D’ÉLECTROCUTION
NE PAS OUVRIR
Cet appareil a été conçu et fabriqué pour assurer votre sécurité personnelle. Mais
UNE UTILISATION INCORRECTE PEUT ENTRAÎNER UN RISQUE D’ÉLECTROCUTION
OU D’INCENDIE.
Respecter les règles de base suivantes pour son installation, utilisation et
entretien, afin de ne pas compromettre les mesures de sécurité incorporées dans
ce produit. Veuillez lire attentivement ces «Consignes de sécurité importantes»
avant utilisation.
1. Lisez ces instructions.
2. Gardez ces instructions.
3. Tenez compte de toutes les mises en garde.
4. Suivez toutes les instructions.
5. N’utilisez pas cet amplificateur à proximité de l’eau.
6. Assurez-vous d’une bonne ventilation de l’appareil. Installez en
accord avec les instructions préconisées par Powersoft.
7. N’installez pas l’appareil à proximité de sources de chaleur ou
d’autres appareils produisant de la chaleur.
8. Respectez le dispositif de mise à la terre de la prise secteur.
9. Utilisez uniquement les accroches et accessoires spécifiés par
Powersoft.
10. Confiez toute réparation à un technicien qualifié. L’intervention
d’un technicien est nécessaire dans les cas suivants : le cordon
d’alimentation ou la prise secteur sont endommagés, des corps
étrangers ou du liquide se sont introduits dans l’appareil, l’appareil
a été exposé à la pluie ou à l’humidité, l’appareil montre des
signes de dysfonctionnement ou est tombé.
11. L’appareil doit être connecté à une prise SECTEUR dotée d’une
mise à la terre de protection.
NE PAS EXPOSER CET APPAREIL A LA PLUIE OU A L’HUMIDITÉ,
AUX GOUTTES OU AUX ÉCLABOUSSURES. LES OBJETS
REMPLIS DE LIQUIDE, TELS QUE LES VASES, NE DOIVENT PAS ETRE
PLACÉS SUR CET APPAREIL.
LES BORNES D’ENCEINTES POURRAIENT ÊTRE DANGEREUX SI
LA CONNEXION DE MODE PONT DU HAUT-PARLEUR EST
UTILISÉ.
ADOPTER DES TECHNIQUES CORRECTES DE CONNEXION ET
D’ISOLEMENT LORSQUE LA CONNEXION EN MODE BRIDGE
HAUT-PARLEUR EST UTILISÉ.
CLASS3
WIRING
LE TRIANGLE AVEC LE SYMBOLE D'UN ÉCLAIR EST UTILISÉ POUR
ALERTER L'UTILISATEUR DU RISQUE DE CHOC ÉLECTRIQUE.
CLASS3
WIRING
LE TRIANGLE AVEC LE POINT D'EXCLAMATION EST UTILISÉ
POUR ALERTER L'UTILISATEUR SUR DES INSTRUCTIONS DE
FONCTIONNEMENT OU D'ENTRETIEN IMPORTANTES.
LE SIGNE CE INDIQUE LA CONFORMITÉ DU PRODUIT À TOUTES
LES DIRECTIVES EUROPÉENNES APPLICABLES
SYMBOLE POUR LA CONNEXION TERRE / MASSE.
SYMBOLE INDIQUANT QUE L'ÉQUIPEMENT EST DESTINÉ À UN
USAGE INTÉRIEUR UNIQUEMENT.
SYMBOLE DE CONFORMITÉ AVEC LA DIRECTIVE 2012/19/
CE DU PARLEMENT EUROPÉEN RELATIVE AUX DÉCHETS
D'ÉQUIPEMENTS ÉLECTRIQUES ET ÉLECTRONIQUES (DEEE).
+35 OC
0 °C
DE 0°C À +35°C
DÉCLASSEMENT AU DESSUS DE 35°C.
10 %
85 %
%DE 10% À 85% D'HUMIDITÉ (SANS CONDENSATION).
NE PAS UTILISER PAS L'APPAREIL À DES ALTITUDES AU-DESSUS
DE 2000 M.
NE PAS UTILISER L'APPAREIL DANS UN ENVIRONNEMENT
TROPICAL.
CLASS3
WIRING
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE DE CHOC
ÉLECTRIQUE, NE PAS ESSAYER D'OUVRIR TOUTE PARTIE DE
L'APPAREIL. AUCUNE PIÈCE RÉPARABLE PAR L'UTILISATEUR
A L'INTÉRIEUR. RENVOYER L'ENTRETIEN AU PERSONNEL DE
SERVICE QUALIFIÉ.
CLASS3
WIRING
LE BRANCHEMENT AU SECTEUR NE SERA EFFECTUE QUE
PAR UNE PERSONNE QUALIFIÉE DANS LE DOMAINE ÉLECTRO-
TECHNIQUE SELON LES EXIGENCES NATIONALES DES PAYS OU
L'APPAREIL EST VENDU.
CLASS3
WIRING
VÉRIFIER QUE VOTRE CONNEXION SECTEUR EST CAPABLE DE
SATISFAIRE LES VALEURS DE PUISSANCE DE L'APPAREIL.
LE FABRICANT NE PEUT ÊTRE TENU RESPONSABLE DES DOMMAGES
CAUSÉS AUX PERSONNES, AUX CHOSES OU AUX DONNÉES EN RAISON
D'UNE CONNEXION À LA TERRE INCORRECTE OU MANQUANTE.
CONTACTER LE CENTRE DE SERVICE AUTORISE POUR UN ENTRETIEN
ORDINAIRE ET EXTRAORDINAIRE.
IL EST ABSOLUMENT NÉCESSAIRE DE VÉRIFIER CES CONDITIONS
FONDAMENTALES DE SÉCURITÉ ET, EN CAS DE DOUTE, D'OBTENIR UNE
VÉRIFICATION PRÉCISE PAR DU PERSONNEL QUALIFIÉ.
iv | Digimod 3004 PFC4 | User guide

Instrucciones de seguridad importantes 3
Este módulo amplicador está diseñado para
ser instalado dentro de otros dispositivos y
debe vericarse en el producto nal. PRECAUCIÓN
RIESGO DE CHOQUE ELÉCTRICO
NO ABRA LA UNIDAD
Esta unidad ha sido diseñada y fabricada para garantizar su seguridad personal.
Pero SU USO INADECUADO PUEDE RESULTAR EN UNA POTENCIAL DESCARGA
ELÉCTRICA O RIESGO DE FUEGO.
Con el fin de no anular las garantías incorporadas en este producto, siga
las siguientes reglas básicas para su instalación, uso y servicio. Por favor lea
cuidadosamente estas “Garantías Importantes” antes de su uso.
1. Lea estas instrucciones.
2. Guarde estas instrucciones.
3. Preste atención a todas las advertencias.
4. Siga todas las instrucciones.
5. No use este aparato cerca del agua.
6. No bloquee las aberturas de ventilación. Realice la instalación de
acuerdo con las indicaciones de Powersoft.
7. No instale cerca ninguna fuente de calor como, por ejemplo,
radiadores, rejillas de calefacción, hornos u otros aparatos que
produzcan calor.
8. No elimine el diseño de seguridad del enchufe, ya sea del tipo po-
larizado o con conexión a tierra.
9. Use exclusivamente los dispositivos/accesorios indicados por
Powersoft.
10. El servicio técnico debe realizarlo siempre personal cualificado. Se
requerirá servicio de asistencia técnica cuando el aparato sufra
algún tipo de daño como, por ejemplo, que el cable de alimentación
o el enchufe estén dañados, que se haya derramado líquido o hayan
caído objetos dentro del aparato, que éste se haya expuesto a la llu-
via o humedad, que no funcione normalmente o que se haya caído.
11. Este aparato deberá ser conectado a un enchufe de salida de red
eléctrica con una protectora conexión a tierra.
NO EXPONGA ESTE UNITAD A LA LLUVIA O LA HUMEDAD,
GOTEO O SALPICADURAS. NO COLOQUE OBJETOS LLENOS DE
LÍQUIDOS, TALES COMO VASIJAS, SOBRE EL APARATO.
TERMINALES DE LOS ALTAVOCES PODRÍA SER PELIGROSO, SI
SU CONEXIÓN SE UTILIZA EL ALTAVOZ MODO PUENTE.
ADOPTAR TÉCNICAS CORRECTAS DE CONEXIÓN Y
AISLAMIENTO CUANDO SE USA CONEXIÓN DE ALTAVOZ MODO
PUENTE.
CLASS3
WIRING
EL TRIÁNGULO CON EL RAYO ES USADO PARA ALERTAR AL
USUARIO DEL RIESGO DE DESCARGA ELÉCTRICA.
CLASS3
WIRING
EL TRIÁNGULO CON EL SIGNO DE EXCLAMACIÓN ES USADO
PARA ALERTAR AL USUARIO DE INSTRUCCIONES DE OPERACIÓN
Y MANTENIMIENTO IMPORTANTES.
EL MARCADO CE INDICA QUE EL PRODUCTO CUMPLE TODAS
LAS DIRECTIVAS EUROPEAS VIGENTES
SÍMBOLO PARA TIERRA/CONEXIÓN A TIERRA.
SÍMBOLO INDICANDO QUE EL EQUIPO ES SOLO PARA USO
INTERIOR.
SÍMBOLO PARA LA CONFORMIDAD CON LA DIRECTIVA 2012/19/
EC DEL PARLAMENTO EUROPEO SOBRE EL DESECHO DE
EQUIPOS ELÉCTRICOS Y ELECTRÓNICOS (WEEE por sus siglas
en Inglés).
+35 OC
0 °C
ENTRE 0°C Y +35°C
DEGRADACIÓN POR ENCIMA DE 35°C.
10%
90%
%ENTRE 10% Y 90% DE HUMEDAD (SIN CONDENSADO).
NO USE LA UNIDAD EN ALTITUDES SOBRE LOS 2000 METROS.
NO USE LA UNIDAD EN AMBIENTES TROPICALES.
CLASS3
WIRING
ADVERTENCIA: PARA REDUCIR EL RIESGO DE DESCARGA
ELÉCTRICA, NO INTENTE ABRIR NINGUNA PARTE DE LA UNIDAD.
NO EXISTEN PARTES INTERNAS REPARABLES PARA EL USUARIO.
REFIERA LA REVISIÓN A PERSONAL DE MANTENIMIENTO
CALIFICADO.
CLASS3
WIRING
LA CONEXIÓN A LA RED ELÉCTRICA DEBERÁ SER EFECTUADA
SOLAMENTE POR UNA PERSONA QUE ESTÉ CAPACITADA
EN EL ÁREA DE ELECTROTÉCNICA DE ACUERDO A LOS
REQUERIMIENTOS NACIONALES DE LOS PAÍSES DONDE LA
UNIDAD SEA VENDIDA.
CLASS3
WIRING
VERIFIQUE QUE SU CONEXIÓN A LA RED ELÉCTRICA ES CAPAZ
DE SATISFACER LOS ÍNDICES DE ENERGÍA DE ESTE DISPOSITIVO.
EL FABRICANTE NO SE HACE RESPONSABLE POR DAÑOS CAUSADOS
A PERSONAS, OBJETOS O DATOS DEBIDO A UNA CONEXIÓN A TIERRA
INAPROPIADA O FALTANTE.
CONTACTE AL CENTRO DE SERVICIO AUTORIZADO PARA
MANTENIMIENTO DE RUTINA O EXTRAORDINARIO.
ES ABSOLUTAMENTE NECESARIO VERIFICAR ESTOS REQUERIMIENTOS
FUNDAMENTALES DE SEGURIDAD Y, EN CASO DE DUDA, EXIJA UN
CORRECTO CHEQUEO POR PARTE DE UN PERSONAL CALIFICADO.
Instrucciones de seguridad importantes | v

Importanti istruzioni di sicurezza 4
Il dispositivo è stato progettato e fabbricato per garantire la vostra sicurezza
personale. TUTTAVIA UN UTILIZZO NON CORRETTO PUO’ PROVOCARE RISCHI DI
SCOSSE ELETTRICHE E DI INCENDI.
Per non compromettere le protezioni incorporate nel prodotto, rispettare le
seguenti regole di base relative all’installazione, all’utilizzo e alla manutenzione.
Si prega di leggere queste “Istruzioni sulla sicurezza” accuratamente prima
dell’utilizzo.
1. Leggere queste istruzioni.
2. Conservare le istruzioni.
3. Tenere conto di tutti gli avvisi.
4. Seguire tutte le istruzioni.
5. Non usare l'apparecchio in prossimità di acqua.
6. Non ostruire le prese di ventilazione. Installare secondo le indica-
zioni del produttore.
7. Non installare vicino a fonti di calore quali radiatori, bocchette
dell'aria calda, stufe o altri apparecchi (compresi gli amplificatori)
che producono calore.
8. Non compromettere la sicurezza delle spine polarizzate o con
messa a terra.
9. Usare solo accessori specificati dal produttore.
10. Ricorrere a personale qualificato per qualsiasi intervento. Tali
interventi sono necessari in caso di guasti dell'apparecchio
quali danneggiamento del cavo di alimentazione o della spina,
versamento di liquidi o caduta di oggetti nell'apparecchio, es-
posizione a pioggia o umidità o se l'apparecchio non funziona
normalmente o è caduto.
11. Il dispositivo deve essere collegato a una presa di corrente con
collegamento protetto da messa a terra.
ATTENZIONE
RISCHIO DI SCOSSE
ELETTRICHE, NON APRIRE
NON ESPORRE QUESTO APPARECCHIO ALLA PIOGGIA,
UMIDITÀ O SOSTANZE LIQUIDE. OGGETTI PIENI DI LIQUIDI,
COME VASI, NON DEVONO ESSERE COLLOCATI SU QUESTO APPARATO.
I TERMINALI DEI DIFFUSORI POTREBBERO ESSERE
PERICOLOSI, SE VIENE UTILIZZATA LA CONNESSIONE IN
MODALITÀ BRIDGE DEGLI ALTOPARLANTI.
ADOTTARE LE CORRETTE TECNICHE DI CONNESSIONE E
ISOLAMENTO QUANDO VIENE UTILIZZATA LA CONNESSIONE
IN MODALITÀ BRIDGE DEGLI ALTOPARLANTI.
Questo modulo amplicatore è destinato ad essere
installato dentro altri dispositivi e deve quindi
essere controllato nel prodotto nito.
IL PRODUTTORE DECLINA OGNI RESPONSABILITA’ PER DANNI
PROVOCATI A PERSONE, COSE O DATI A CAUSA DI UN COLLEGAMENTO
NON CORRETTO O MANCANTE DELLA MESSA A TERRA.
CONTATTARE IL CENTRO DI ASSISTENZA AUTORIZZATO PER ESEGUIRE
LA MANUTENZIONE ORDINARIA E STRAORDINARIA.
E’ ASSOLUTAMENTE NECESSARIO CONTROLLARE QUESTI REQUISITI
FONDAMENTALI SULLA SICUREZZA E, IN CASO DI DUBBI, RICHIEDERE
UN CONTROLLO ACCURATO DA PERSONALE QUALIFICATO.
CLASS3
WIRING
IL TRIANGOLO CON IL SIMBOLO DEL FULMINE VIENE UTILIZZATO
PER AVVISARE L’UTENTE SUL RISCHIO DI SCOSSE ELETTRICHE.
CLASS3
WIRING
IL TRIANGOLO CON IL PUNTO ESCLAMATIVO VIENE UTILIZZATO
PER AVVISARE L’UTENTE SU IMPORTANTI ISTRUZIONI DI
FUNZIONAMENTO O DI MANUTENZIONE.
LA MARCATURA CE INDICA LA CONFORMITÀ DEL PRODOTTO A
TUTTE LE DIRETTIVE EUROPEE IN VIGORE
SIMBOLO PER IL COLLEGAMENTO DELLA MESSA A TERRA.
SIMBOLO CHE INDICA CHE IL DISPOSITIVO PUO’ ESSERE
UTILIZZATO SOLO ALL’INTERNO.
SIMBOLO INDICANTE LA CONFIORMITA’ ALLA DIRETTIVA
2012/19/CE DEL PARLAMENTO EUROPEO SUI RIFIUTI DI
APPARECCHIATURE ELETTRICHE ED ELETTRONICHE (RAEE).
+35 OC
0 °C
DA 0°C A +35°C
DERATING OLTRE I 35°C.
10%
90%
%DAL 10% AL 90% DI UMIDITÀ (NON CONDENSANTE).
NON UTILIZZARE IL DISPOSITIVO AD ALTITUDINI SUPERIORI A
2000 M.
NON UTILIZZARE IL DISPOSITIVO IN UN AMBIENTE TROPICALE.
CLASS3
WIRING
ATTENZIONE: PER RIDURRE IL RISCHIO DI SCOSSE ELETTRICHE
NON TENTARE DI APRIRE ALCUNA PARTE DEL DISPOSITIVO.
ALL’INTERNO NON E’ PRESENTE ALCUN COMPONENTE
RIPARABILE DALL’UTENTE. PER L’ASSISTENZA RIVOLGERSI A
PERSONALE TECNICO QUALIFICATO.
CLASS3
WIRING
IL COLLEGAMENTO ALLA RETE ELETTRICA DEVE ESSERE
ESEGUITO DA UN ELETTROTECNICO QUALIFICATO ATTENENDOSI
AI REQUISITI DEL PAESE IN CUI IL DISPOSITIVO VIENE VENDUTO.
CLASS3
WIRING
CONTROLLARE CHE LA CONNESSIONE DI RETE SIA IN GRADO DI
SODDISFARE LA POTENZA NOMINALE DEL DISPOSITIVO.
vi | Digimod 3004 PFC4 | User guide

FCC COMPLIANCE NOTICE
This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment gener-
ates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the
following measures:
f Reorient or relocate the receiving antenna.
f Increase the separation between the equipment and receiver.
f Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
f Consult the dealer or an experienced radio/TV technician for help.
WEEE DIRECTIVE
If the time arises to throw away your product, please recycle all the
possible components.
This symbol indicates that when the end-user wishes
to discard this product, it must be sent to separate col-
lection facilities for recovery and recycling. By separat-
ing this product from other household-type waste, the
volume of waste sent to incinerators or land-fills will be
reduced and natural resources will thus be conserved.
The Waste Electrical and Electronic Equipment Directive (WEEE Directive)
aims to minimise the impact of electrical and electronic goods on the en-
vironment. Powersoft S.p.A. comply with the Directive 2002/96/EC and
2003/108/EC of the European Parliament on waste electrical finance the
cost of treatment and recovery of electronic equipment (WEEE) in order
to reduce the amount of WEEE that is being disposed of in land-fill site.
All of our products are marked with the WEEE symbol; this indicates that
this product must NOT be disposed of with other waste. Instead it is the
user’s responsibility to dispose of their waste electrical and electronic
equipment by handing it over to an approved reprocessor, or by return-
ing it to Powesoft S.p.A. for reprocessing. For more information about
where you can send your waste equipment for recycling, please contact
Powesoft S.p.A. or one of your local distributors.
Regulatory information 5
EC DECLARATION OF CONFORMITY
Manufacturer:
Powersoft S.p.A.
via E. Conti 5
50018 Scandicci (Fi)
Italy
We declare that under our sole responsibility the products:
Model Name: Digimod 3004 PFC4
Intended use: Professional Audio Amplifier Module
Are in conformity with the provisions of the following EC Directives,
including all amendments, and with national legislation implementing
these directives:
2014/35/EU Low Voltage Directive
2014/30/EU Electromagnetic Compatibility Directive
2011/65/EU RoHs Directive
The following harmonized standards are applied:
EN 55103-1:2009,
EN 55103-1:2009/A1:2012
EN 55103-2:2009
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61000-3-11:2000
EN 60065:2014
EN 60065:2014/AC:2016
Scandicci,
27 August 2020
For compliance questions only: compliance@powersoft.it
4
DECLARATION OF CONFORMITY
The Manufacturer:
Declare that under our sole responsibility the products that:
V
Are in conformity with the provisions of the following EC Direc�ves, including all amendments, and with
na�onal legisla�on implemen�ng these direc�ves:
−
−
−
The following harmonized standards are applied:
−
−
−
−--
−--
−--
−-
−EN -
Regulatory information | vii

Electrostatic Discharge (ESD) 6
Electrostatic discharge (ESD) is one of the most signi-
cant factors leading to damage and failure of a wide variety
of electronic components.
Poor handling can cause internal damage, which is
invisible. This internal damage can then cause electrical
failure or reliability problems.
It is recommended that all workstations where
Electrostatic Discharge Sensitive devices (ESDS)
and assemblies are handled outside of full static protection
packaging (i.e. within static control areas) should be pro-
vided with some form of ground conductive or dissipative
ooring.
viii | Digimod 3004 PFC4 | User guide

6 Digimod 3004 PFC4 User Guide 7
7:1.Welcome
Congratulations on your purchase of the Powersoft
DigiMod 3004PFC4 module.
We know you are eager to use the DigiMod 3004PFC4
module, but please take a moment to read this user’s man-
ual and safety instructions. In case you have any questions,
please do not hesitate to contact your dealer or Powersoft.
The DigiMod 3004PFC4 is a four channel amplier mod-
ules specically designed to drive high power loudspeakers.
The DigiMod 3004PFC4 represents an important evolu-
tion in the DigiMod Series family of products: delivering up
to 1000 W on 4 � per channel (2000W on 8 � in mono-
bridged mode), the DigiMod 3004PFC4 reaches a new level
of excellence in terms of power consumption and sonic
performance.
The xed frequency switching mode technology design
guarantees maximum performances, high efciency and
predictability ensuring total immunity from intermodulation
artifacts. The new design of the power supply equipped
with PFC and Smart Rails Management reduces power
consumption and enhances reliability and consistency in
all operating conditions.
The DigiMod 3004PFC4 shares the same compact me-
chanical layout of the other DigiMod Series models guaran-
teeing scalability to existing and future implementations and
is fully compatible with all existing Powersoft DSP solutions
providing a powerful and exible signal processing tools on
board of your loudspeaker.
7:2.Unpacking&checking for shipping damage
Your Powersoft product has been completely tested and
inspected before leaving the factory. Carefully inspect the
shipping package before opening it, and then immediately
inspect your new product. If you nd any damage notify the
shipping company immediately.
7:3.Disposal of the packing material
The transport and protective packing has been selected
from materials which are environmentally friendly for dis-
posal and can normally be recycled.
Rather than just throwing these materials away, please
ensure they are offered for recycling.
Digimod 3004 PFC4 | 1

8
Thermal constraints
This device must be correctly heatsinked for proper and
reliable operation: an appropriate external passive heat sink
guarantees by design thermal efciency and reliability.
Proper heatsink planarity is strongly suggested to al-
low thermal transfer from the module’s bottom plate to the
heatsink; a thermal compound may be used, but it is not
strictly necessary.
In order to ensure proper ventilation of the module, rea-
sonable spacing of at least 100 mm must be left between
the frame of the unit and any side component or surface of
the enclosure.
The module has been designed to t into a loudspeaker
cabinet: please refer to FIGURE 1 for proper module placing.
IN FIGURE 1 HEATSINK FINS ARE SET HORIZONTALLY
(WRONG!) ONLY FOR DESCRIPTIVE PURPOSE.
All conguration showed in FIGURE 1 are viable for
proper module placing and cooling. We suggest to posi-
tion the module vertically with respect the ground in order
to take advantage of the chimney effect for ventilation and
heat dissipation.
In FIGURE 1.athe module and the loudspeakers share
the same room into the cabinet. This is the default place-
ment solution: it allows good ventilation because of woofer
diaphragm movement and high air volume; be aware of
magnetic eld interaction: place the module far enough from
loudspeakers magnet in order to prevent fans blockage.
FIGURE 1.bshows the more efcient cooling congura-
tion, even if it is less effective against dust and moisture
that can get into the module. By allowing external air ow,
it is possible to reduce the ns width on the heatsink by
maintaining good cooling performances.
8:1.Heatsink performance
Here we suggest a rule of thumb to calculate the thermal
resistance of the heatsink.
The absolute thermal resistance of the heatsink is the
temperature difference (kelvin or celsius) across its structure
when a unit of heat energy ows through it in unit time (watt).
For seek of simplicity: a heatsink with low thermal resistance
offers high heat dissipation, as well as a low electric resist-
ance allows high current owing through a conductive wire.
In order to dene the maximum allowed thermal resist-
ance for the heatsink let assume the following:
f eas the amp module efciency
f cf as the crest factor of the audio signal
f Wmax as the peak power delivered by the module
f Tamb as the highest ambient temperature
f Tmod as the highest operating temperature
The thermal resistance of the heatsink derives from the fol-
lowing formula:
meaning that the temperature of the bottom plate is always
lower than 75°C if the heatsink has a thermal resistance
better than 0.14°C/W (or 0.14 K/W) with ambient temperature
up to 45 °C.
For example, stating an efciency of 80%, 6 dB crest factor
and 3400 W peak power, the dissipated heat is:
Supposing that the thermal protection of the module (Tmod) is
set at 75°C (167°F) on the bottom plate and stating an ambi-
ent temperature of 45 °C (113°F), the previous example gives:
100 mm
3.94 inch
Be aware of
magnetic leakage
MIN.
Do not obstruct
air ow
Be aware of
air leakage
FIGURE 1: Cooling solutions
(for descriptive purpose
the heatsink fins are set in
wrong direction);
a) Module and loudspeaker
into the same chamber;
b) Module in a separate
vented chamber.
Dissipated power = cf
Wmax (1 - e)
Rth = Dissipated power
Tmod - Tamb
= 0.14°C/W
170
75 - 45
= 170 W
4
3400 (1 - 0.8)
a
b
The maximum dissipated power can be calculated as:
2 | Digimod 3004 PFC4 | User guide

8 9
Electromagnetic Compatibility (EMC) & Safety
9:1.AC MAINS filter
This equipment has been tested and found to be compliant
with regulations listed in “Reference Standard” section.
This equipment is compliant with Class A of CISPR 32. In
a residential environment this equipment may cause radio
interference.
In order to improve the electromagnetic compat-
ibility performance an EMC lter must be inserted
before the AC MAINS plugs on the power supply. An
example of the suggested lter topology is reported below:
9:2.Cabling
Wiring between the amp module and the load may lead
to radio frequency noise. The following guide lines should
be observed:
f reduced cabling length is advisable;
f keep cable pairs as close as possible to each other in
order to minimize the antenna effect;
f design the cabling path far from RF noise source;
f set the cabling for RF noise rejection: shielded or twist-
ed cables are advisable conguration (ref. FIGURE 4);
f place ferrites as close to the module as possible
9:3.Ferrite cores
Reject RF noise from input and output cabling by in-
stalling ferrite shields. Powersoft suggests the FAIR RITE
0431164181, or equivalent.
9:5.Mains Fuse
Mains voltage cable must by protected by an external
Time delay fuse of 10A rating (time lag, Littlefuse Series
215). Replace the fuse with the same type and rating.
Wrap both cables around one side of each ferrite so that
it pass through each ferrite twice (ref. FIGURE 3). Install the
ferrite shield as close as possible to where the cable plugs
into the amplier. Placing the ferrite elsewhere on the cable
noticeably reduces its effectiveness.
9:4.Chassis shielding
If not already present on the product, a full body metal
chassis or a shielding cage will provide best shielding of RF
emission. In order to achieve the highest shielding, minimize
the amount and size of holes or opening in the chassis.
FIGURE 2: Typical electrical schematic of the EMI Filter.
FIGURE 3: Ferrite core installation on I/O wirings.
Loose pair
Configuration
prone to high
RF noise
Parallel pair
Configuration
prone to RF noise
Twisted pair
Highly immune
to RF noise
Shielded pair
Highly immune
to RF noise
FIGURE 4: Cabling configuration.
Input
signal
FIGURE 5: Tools and best practice for improving
the electromagnetic compatibility.
AC MAINS filter
Chassis shielding
Amp module
inside
Ferrite core
Ferrite core
Output signal
9:6.Earth connection
This device must be powered exclusively by earth
connected mains sockets in electrical networks
compliant to the IEC 364 or similar rules. Is absolutely nec-
essary to verify this fundamental requirement of safety and,
in case of doubt, require an accurate check by a qualied
personal.
Is absolutely necessary to ground this device using the
proper earth connection on the metal frame of the chas-
sis; use M4 nut and bolt with proper split washer – grover
washer – to secure the earth terminal lug.
Electromagnetic Compatibility (EMC) & Safety | 3

4 | Digimod 3004 PFC4 | User guide
10
Mechanical drawings
FIGURE 6: Digimod 3004 PFC4 side and back plate (all dimensions in millimeters).
78.6
Ø 4.2 THROUGH HOLE
N°5 POS.
283.3
13.1
38.923.9
104.349.830.149.8
81.1
M3 THREADED
HOLE
N°14 POS.
300.5
54.2
108.4
29.2 9.7
122
308.5
Warning! The lenght of the
thread of the M3 threaded holes
is not guaranteed to be the
same across the module

Connections | 5
10 Connections
FIGURE 7:DigiMod 3004PFC4 – AC MAINS and audio output wiring:
a. Four ways – four single channels;
b. Three ways – channels 3-4 in bridge mode;
c. Three ways – channels 1-2 in bridge mode;
d. Two ways – channels 1-2 and 3-4 in bridge mode.
GROUND
AC MAINS
Channel 1
Channel 3Channel 4
Channel 2
Faston
6.3 x 0.8 mm
Faston
6.3 x 0.8 mm
Channel 3Channel 4
Faston
6.3 x 0.8 mm
Channel 1Channel 2
Bridge 3-4
Bridge 3-4
Bridge 1-2
Faston
6.3 x 0.8 mm
Bridge 1-2
Faston
6.3 x 0.8 mm
GROUND
AC MAINS
Channel 1
Channel 3Channel 4
Channel 2
Faston
6.3 x 0.8 mm
Faston
6.3 x 0.8 mm
Channel 3Channel 4
Faston
6.3 x 0.8 mm
Channel 1Channel 2
Bridge 3-4
Bridge 3-4
Bridge 1-2
Faston
6.3 x 0.8 mm
Bridge 1-2
Faston
6.3 x 0.8 mm
GROUND
AC MAINS
Channel 1
Channel 3Channel 4
Channel 2
Faston
6.3 x 0.8 mm
Faston
6.3 x 0.8 mm
Channel 3Channel 4
Faston
6.3 x 0.8 mm
Channel 1Channel 2
Bridge 3-4
Bridge 3-4
Bridge 1-2
Faston
6.3 x 0.8 mm
Bridge 1-2
Faston
6.3 x 0.8 mm
GROUND
AC MAINS
Channel 1
Channel 3Channel 4
Channel 2
Faston
6.3 x 0.8 mm
Faston
6.3 x 0.8 mm
Channel 3Channel 4
Faston
6.3 x 0.8 mm
Channel 1Channel 2
Bridge 3-4
Bridge 3-4
Bridge 1-2
Faston
6.3 x 0.8 mm
Bridge 1-2
Faston
6.3 x 0.8 mm
a b
c
d

6 | Digimod 3004 PFC4 | User guide
10:1.1.Main connectors pinout
The following image and tables show the pinout of main
input and output connectors and the SIMM board.
FIGURE 6 shows the default jumpers conguration for
the Bypass connectors. By means of these jumpers it is
possible to change the main gain and enable the DSP and
external circuits.
Gain at +38dB is intended for low level inputs which
need more boost, such as consumer devices; take care
on raising the gain since this involves more noise at output
stages.
DSP and external circuits – such as lters or volume
regulators– can be independently activated by removing
related jumpers on PL1000 for channel 1, PL2000 for chan-
nel 2, PL3000 for channel 3 and PL4000 for channel 4. Both
DSP and external circuits can be layed on a 72-pin SIMM
board which would be plugged
into the SO5 Socket; for
more informations about SIMM specications, please con-
tact Powersoft. SIMM board pinout is shown on FIGURE 8.
10:1.2.Bill of connectors
CODE NAME TYPE
SO5 DSP/external circuit board
socket 72-pin SIMM Socket
PL1003 Input connector channels
1 & 2 IDC at cable 34 ways
PL3003 Input connector channels
3 & 4 IDC at cable 34 ways
PL2 Test Connector (reserved) IDC at cable 20 ways
PL1001 Signal OUT 1 + Faston 6.3x0.8 mm Male
PL1002 Signal OUT 1 –
(GND) Faston 6.3x0.8 mm Male
PL2001 Signal OUT 2 – Faston 6.3x0.8 mm Male
PL2002 Signal OUT 2 +
(GND) Faston 6.3x0.8 mm Male
PL3001 Signal OUT 3 + Faston 6.3x0.8 mm Male
PL3002 Signal OUT 3 –
(GND) Faston 6.3x0.8 mm Male
PL4001 Signal OUT 4 – Faston 6.3x0.8 mm Male
PL4002 Signal OUT 4 +
(GND) Faston 6.3x0.8 mm Male
PL1000 Bypass Channel 1
PL2000 Bypass Channel 2
PL3000 Bypass Channel 3
PL4000 Bypass Channel 4
PL1 reserved Molex 22-27-2031
PL7 FAN Molex 22-27-2031
PL22 FAN Molex 22-27-2031
PL23 FAN Molex 22-27-2031
PL24 FAN Molex 22-27-2031
PL25 Test Connector (reserved) Molex 22-27-2031
Channel 1
GND
HOT
COLD
Channel 3
GND
HOT
COLD
Channel 2
GND
COLD
HOT
Channel 4
GND
COLD
HOT
Parallel 1&2
GND
HOT
COLD
Parallel 3&4
GND
HOT
COLD
Channel 1
GND
HOT
COLD
Channel 3
GND
HOT
COLD
Channel 2
GND
COLD
HOT
Channel 4
GND
COLD
HOT
Parallel 1&2
GND
HOT
COLD
Parallel 3&4
GND
HOT
COLD
PIN 1
Jumpered
Not jumpered
PL1003
PL3003
PL1000
(Channel 1)
(Channel 3)
(Channel 4)
(Channel 2)
PL2000
PL3000
PL4000
Place jumper to
switch gain to 38 dB
Remove jumper
to enable DSP
Remove jumper to
insert external circuit
Mating x fan: Molex 22-01-2035
Terminals: KK254 4809 Series
FIGURE 8: DigiMod 3004PFC4 – four input channels wiring. FIGURE 10: DigiMod 3004PFC4 – parallel input wiring.
FIGURE 9: DigiMod 3004PFC4 bypass connectors pinout

Connections | 7
FIGURE 11: DigiMod 3004PFC4 surface components layout.

8 | Digimod 3004 PFC4 | User guide
10:2.PL1003 pinout
PIN# Name IN OUT POWER Range Scale
factor Imped-
ance Protected Tolle-
rance Description
1SDPWS
Active High,
Logic input 3.3 to 12 Vdc
do not use the internal
aux power supply, an
external power supply
is needed.
1 k� Logic input
to be fed by
“OR” diode
Power Supply Shut
Down
2READY 1 Active High
3.3 V - 5 V 47 k� Signal Ready CH 1
3RESERVED
4RESERVED
5GND Ground
6 IN 1 +
Unbalanced
1.92 Vrms for Full Output;
7 Vrms Absolute Max
Input
Balanced
0.96 Vrms for Full Output;
3.5 Vrms Absolute Max
Input
10 k�
Channel 1
Positive Balanced Input
32 dB
Input To Output Overall
Gain
7 IN 1 –
Unbalanced
1.92 Vrms for Full Output;
7 Vrms Absolute Max
Input
Balanced
0.96 Vrms for Full Output;
3.5 Vrms Absolute Max
Input
10 k�
Channel 1
Negative Balanced
Input
32 dB
Input To Output Overall
Gain
8GND Ground
9VOUT1MON 20 V/V4.5 k� Channel 1
Output Voltage Monitor
10 PROTECT1
Level 1
(2 to 10) = not in
Protection
Level 0 (0 to 1) =
Protection
100 k� Channel 1
Output Stage Protection
Monitor
11 IOUT1MON 7.5 A/V4.5 k� Channel 1
Output Current Monitor
12 TEMPMON12 0 – 5 V See
table 7 k� NTC sensor tap output
13 +12VDCOUT +12 Vdc; 0.5 A max out-
put current available Polyswitch ±5% Positive regulated
analog section supply
(same as pin 22)
14 -12VDCOUT –12 Vdc; 0.5 A max out-
put current available Polyswitch ±5% Negative regulated
analog section supply
(same as pin 21)
15 MUTE
Active Low,
To be pulled to GND by
current sink of at least
20 mA
CH1 and CH2
Output Stage Mute
(disable output stages
PWM)
Table continues on the next page...

Connections | 9
PIN# Name IN OUT POWER Range Scale
factor Imped-
ance Protected Tolle-
rance Description
16 +VCCMON +7.5 Vdc 4.5 k� Rail Bus Positive
Monitor
17 -VCCMON –7.5 Vdc 4.5 k� Rail Bus Negative
Monitor
18 -VCCMON –7.5 Vdc 4.5 k� Rail Bus Positive
Monitor
19 +VCCMON +7.5 Vd4.5 k� Rail Bus Negative
Monitor
20 MUTE
Active Low,
To be pulled to GND by
current sink of at least
20 mA
CH1 and CH2
Output Stage Mute
(disable output stages
PWM)
21 -12VDCOUT –12 Vdc; 0.5 A max out-
put current available Polyswitch ±5% Negative regulated
analog section supply
(same as pin 21)
22 +12VDCOUT +12 Vdc; 0.5 A max out-
put current available Polyswitch ±5% Positive regulated
analog section supply
(same as pin 22)
23 TEMPMON12 0 – 5 V See
table 7 k� NTC sensor tap output
24 IOUT2MON 7.5 A/V4.5 k� Channel 2
Output Current Monitor
25 PROTECT2
Level 1
(2 to 10) = not in
Protection
Level 0 (0 to 1) =
Protection
100 k� Channel 2
Output Stage Protection
Monitor
26 VOUT2MON 20 V/V4.5 k� Channel 2
Output Voltage Monitor
27 GND Ground
28 IN 2 –
Unbalanced
1.92 Vrms for Full Output;
7 Vrms Absolute Max
Input
Balanced
0.96 Vrms for Full Output;
3.5 Vrms Absolute Max
Input
10 k�
Channel 2
Negative Balanced
Input
32 dB
Input To Output Overall
Gain
29 IN 2 +
Unbalanced
1.92 Vrms for Full Output;
7 Vrms Absolute Max
Input
Balanced
0.96 Vrms for Full Output;
3.5 Vrms Absolute Max
Input
10 k�
Channel 2
Positive Balanced Input
32 dB
Input To Output Overall
Gain
30 GND Ground
31 RESERVED
32 RESERVED
33 READY 2 Active High
3.3 V - 5 V 47 k� Signal Ready CH 2
34 SDPWS
Active High,
Logic input 3.3 to 12 Vdc
do not use the internal
aux power supply, an
external power supply
is needed.
1 k� Logic input
to be fed by
“OR” diode
Power Supply Shut
Down
...continued from previous page.

10 | Digimod 3004 PFC4 | User guide
10:3.PL3003 pinout
PIN# Name IN OUT POWER Range Scale
factor Imped-
ance Protected Tolle-
rance Description
1SDPWS
Active High,
Logic input 3.3 to 12 Vdc
do not use the internal
aux power supply, an
external power supply
is needed.
1 k� Logic input
to be fed by
“OR” diode
Power Supply Shut
Down
2READY 3 Active High
3.3 V - 5 V 47 k� Signal Ready CH 3
3RESERVED
4RESERVED
5GND Ground
6 IN 3 +
Unbalanced
1.92 Vrms for Full Output;
7 Vrms Absolute Max
Input
Balanced
0.96 Vrms for Full Output;
3.5 Vrms Absolute Max
Input
10 k�
Channel 3
Positive Balanced Input
32 dB
Input To Output Overall
Gain
7 IN 3 –
Unbalanced
1.92 Vrms for Full Output;
7 Vrms Absolute Max
Input
Balanced
0.96 Vrms for Full Output;
3.5 Vrms Absolute Max
Input
10 k�
Channel 3
Negative Balanced Input
32 dB
Input To Output Overall
Gain
8GND Ground
9VOUT3MON 20 V/V4.5 k� Channel 3
Output Voltage Monitor
10 PROTECT3
Level 1
(2 to 10) = not in
Protection
Level 0 (0 to 1) =
Protection
100 k� Channel 3
Output Stage Protection
Monitor
11 IOUT1MON 7.5 A/V4.5 k� Channel 3
Output Current Monitor
12 TEMPMON34 0 – 5 V See
table 7 k� NTC sensor tap output
13 +12VDCOUT +12 Vdc; 0.5 A max out-
put current available Polyswitch ±5% Positive regulated analog
section supply
(same as pin 22)
14 -12VDCOUT –12 Vdc; 0.5 A max out-
put current available Polyswitch ±5% Negative regulated
analog section supply
(same as pin 21)
15 MUTE
Active Low,
To be pulled to GND by
current sink of at least
20 mA
CH3 and CH4
Output Stage Mute
(disable output stages
PWM)
Table continues on the next page...
Other manuals for DigiMod 3004PFC4
2
Table of contents
Other powersoft Control Unit manuals

powersoft
powersoft DigiMod IS integration kit Instruction Manual

powersoft
powersoft MiniMod 4 User manual

powersoft
powersoft DigiMod IS Series Specification sheet

powersoft
powersoft LiteMod 4HC User manual

powersoft
powersoft LiteMod User manual

powersoft
powersoft M-Drive Series User manual

powersoft
powersoft IpalMod User manual

powersoft
powersoft DSP LITE User manual

powersoft
powersoft LiteMod 4HC User manual

powersoft
powersoft DigiMod 1000 NPS Safety guide