INSTALLATION GUIDE


CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This unit has been engineered and manufactured to ensure your
personal safety. But IMPROPER USE CAN RESULT IN POTENTIAL
ELECTRICAL SHOCK OR FIRE HAZARD.
In order not to defeat the safeguards incorporated into this product,
Please Read these “Important Safeguards” carefully before use.
1.
2.
3. Heed all warnings.
4.
5. Do not use this equipment near water.
6. Do not install near any heat sources such as radiators, heat
registers, stoves or other apparatus that produce heat.
7.
required when the apparatus has been damaged in any way,
such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate
normally, or has been dropped.
CLASS3
WIRING
THE TRIANGLE WITH THE LIGHTNING BOLT IS USED TO ALERT THE USER TO THE
RISK OF ELECTRIC SHOCK.
CLASS3
WIRING
THE TRIANGLE WITH THE EXCLAMATION POINT IS USED TO ALERT THE USER
TO IMPORTANT OPERATING OR MAINTENANCE INSTRUCTIONS.
THE CE-MARK INDICATES THE COMPLIANCE OF THE PRODUCT TO ALL THE
APPLICABLE EUROPEAN DIRECTIVES
SYMBOL FOR EARTH/GROUND CONNECTION.
SYMBOL FOR CONFORMITY WITH DIRECTIVE 2012/19/EC OF THE EUROPEAN
PARLIAMENT ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE).
+45 C
0 °C
OPERATING TEMPERATURE 0°C TO +45°C.
20%
85%
%20% TO 85% HUMIDITY (NON CONDENSING).
DO NOT USE THE UNIT AT ALTITUDES ABOVE 2000 M.
DO NOT USE THE UNIT IN TROPICAL ENVIRONMENT.
CLASS3
WIRING
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT ATTEMPT TO
OPEN ANY PART OF THE UNIT. NO USER-SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED SERVICE PERSONNEL.
CLASS3
WIRING
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE, DRIPPING OR
SPLASHING LIQUIDS. OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD
NOT BE PLACED ON THIS APPARATUS.
This product enables the control of audio system features when used in
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED
TO PERSONS, THINGS OR DATA DUE TO AN IMPROPER OR MISSING GROUND
CONNECTION.
CONTACT THE AUTHORIZED SERVICE CENTER FOR ORDINARY AND
EXTRAORDINARY MAINTENANCE.
IT IS ABSOLUTELY NECESSARY TO VERIFY THESE FUNDAMENTAL REQUIREMENTS
OF SAFETY AND, IN CASE OF DOUBT, REQUIRE AN ACCURATE CHECK BY
QUALIFIED PERSONNEL.

FCC COMPLIANCE NOTICE
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
generates, uses, and can radiate radio frequency energy and, if not
the interference by one or more of the following measures:
f Reorient or relocate the receiving antenna.
f
f
from that to which the receiver is connected.
f Consult the dealer or an experienced radio/TV technician for help.
WEEE DIRECTIVE
possible components.
This symbol indicates that when the end-user wishes
to discard this product, it must be sent to separate
waste, the volume of waste sent to incinerators or land-
conserved.
electronic equipment (WEEE) in order to reduce the amount of
All of our products are marked with the WEEE symbol; this indicates
that this product must NOT be disposed of with other waste. Instead
it is the user’s responsibility to dispose of their waste electrical and
electronic equipment by handing it over to an approved reprocessor,
distributors.
Regulatory Informaon
EMC EMISSION
This equipment has been tested and found to be compliant with
This equipment is compliant with Class A of CISPR 32.
interference.

Electrostac Discharge (ESD)
leading to damage and failure of a wide variety of electronic
components.
Poor handling can cause internal damage, which is invisible. This
internal damage can then cause electrical failure or reliability
problems.
Support and warranty

Package List
The box contains the following:
• 1x WM Touch
•
• 1x Wall-mount removal pin
•
Overview
over the network via RJ45 cable, and one WM Touch can handle the
Installaon
The screen can be wall mounted to single-gang electrical boxes, and
PoE switch is necessary for powering the WM Touch and a regular
The WM Touch must always be in the same network that is connected
Compability
Conguraon
WM Touch Installaon Guide

Soware Conguraon
•
•
•
• System standby ON/OFF.
• Edit the device name & IP address.
• Change the screen lock display logo.
• Set a 4-digit passcode to exit the screen lock.
.
Local Conguraon
Language and Screen Orientaon
Idenfy
Hidden Sengs Menu
the menu, select ‘More’ from the main ribbon menu (only visible
when the system is running). Press and hold the ‘Project Info’ icon
Screen Lock & Timer
The touch screen can be manually locked by pressing More > Lock
following QR code. You will be redirected to the WM Touch product
tutorial.

Wall-Box Installaon
1
2 3 4
Portrait Mode Landscape Mode
Do not install too close to any wall or object that
may inhibit the removal of the WM Touch from
the metal plate.
CLACK!
CLACK!
CLACK!
CLACK!
CLACK!

1
2 3
CLACK!
CLACK!
CLACK!
CLACK!
Removal

Duecanali
STATUS
NETWORK
SIGNAL
70V
100V
25V
CAL
6s
3s
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
MAINS
2 1
2 IN 1 OUT4 3
MEZZO 322 AD
SWITCHED
CTRL +CTRL +
CTRL
STATUS
NETWORK
SIGNAL
SWITCHED
70V
100V
25V
CAL
6s
3s
CTRL +CTRL +
CTRL
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
MAINS
2 1
2 IN 1 OUT4 3
MEZZO 602 AD
SWITCHED
CTRL +CTRL +
CTRL
STATUS
NETWORK
SIGNAL
70V
100V
25V
CAL
6s
3s
I4 I3 I2 I1 5V
IN2 1
-10 dBV
4 IN 3
MAINS
4 3 2 1
2 IN 1
MEZZO 324 AD
STATUS
NETWORK
SIGNAL
SWITCHED
70V
100V
25V
CAL
6s
3s
CTRL +CTRL +
CTRL
I4 I3 I2 I1 5V
IN2 1
-10 dBV
4 IN 3
MAINS
4 3 2 1
2 IN 1
MEZZO 604 AD
PoE
PoE
PoE
Connecons

Specicaons
Dimensions L: 127.4 mm x H: 86.4mm x D:14.4 mm
LCD Screen 4.3 inch
16:9 (W:H)
Wall mount
Landscape or portrait
Brightness 300 nits
Power Supply (not included) PoE Injector or PoE Switch
Weight 160 g
0°C to 45 °C
RJ45 (100 Mbps)
Max Cable Length 100 m (Cat5 or above)
USB Service only
Included Accessories
1x Wall-mount removal pin
Reference Standard
EN 60068-2-64: 2008 (Random Test)
EN 60068-2-27:2009 (Shock Test)
EMC immunity EN 55035:2017
EMC emissions EN 55032:2012,
EN 55032:2012/AC:2013
Safety standards EN 62368-1:2014
EN 62368-1:2014/AC:2015