Prem-I-Air PJ152NP User manual

HEPA Air Purifier
• Position the air purifier on a stable horizontal surface.
Do not obstruct the air inlet and air outlet.
• This machine is for indoor use only.
• Do not run the air purifier without using a filter.
USER MANUAL
MODEL PJ152NP
Please read this instruction manual
before operating and keep safe for future reference

IMPORTANT SAFETY INSTRUCTIONS
1
When using any electrically powered product, basic safety precautions should always
be followed.
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THE PRODUCT.
1. Check the household voltage to ensure it matches the units rated specification before
operating.
2. Close supervision is necessary when the unit is used by or near children or pets, or left
unattended.
3. Do not allow children to play with any product packaging, such as plastic bags.
4. Do not operate the unit with a damaged cord or plug, after the product malfunctions, or
has been dropped of damaged in any way. Return the complete product to an authorised
service facility for examination and repair.
5. This product is intended for domestic use only and not for commercial, industrial or
outside use.
6. Always turn the unit off and unplug before moving location.
7. To disconnect from the power supply, grip the plug and pull from the power socket.
Never pull by the cord.
8. Do not operate the unit in areas where petrol, paint, or other flammable liquids are used
or stored.
9. Do not use the unit in artificially hot or humid conditions or allow it to be used in any
hazardous environment.
10. Do not place the unit near an open flame, cooking or heating appliance, or hot surface.
11. This unit is not intended for use in wet or damp locations. Never locate the unit in an
area where it may fall into a bath or other water container. Always use on a dry level
surface.
12. Do not let the power cord hang over the edge of a table or counter. Arrange the power
cord away from an area where it may be tripped over.
13. Never place the power cord under a carpet or rug.
14. Do not place objects on the product or allow objects to obstruct the inlet or outlet
openings. Do not operate in close proximity to walls or curtains, etc.
15. The use of attachments or accessories not recommended or sold by the product
distributor is not recommended as they may cause injury to persons or property and
void the warranty.
16. Do not attempt to repair the unit other than to replace or clean the filters. To repair the
unit take it to a qualified service engineer.
17. Set on "high speed" to clean room air rapidly and then turn to lower speed half an hour
later. When used at night, set the speed at lower grade to keep the air fresh and clean.
18. Do not wash the filter cartridge (HEPA). The cartridge is not washable and doing so will
cause damage.
19. Place the unit 90cm above floor level for best performance. The unit should never be
used at floor level if the room is carpeted.
20. If the supply cord is damaged it must be replaced by the Manufacturer or an authorised
service centre in order to avoid a hazard.
SAVE AND READ THESE IMPORTANT SAFETY INSTRUCTIONS

2
BS PLUG WIRING
Wiring Instructions: Should it be necessary to change the plug please note the wires
in the mains lead are coloured in accordance with the following code :
BLUE - NEUTRAL
BROWN - LIVE
GREEN AND YELLOW - EARTH
As the colours of the wires in the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows:
1. The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked
with the letter Nor coloured BLACK.
2. The BROWN wire is the LIVE and must be connected to the terminal which is marked
with the letter Lor coloured RED.
3. The GREEN/YELLOW is the EARTH and must be connected to the terminal which is
marked with the letter Eor or coloured GREEN OR GREEN/YELLOW.
4. Always ensure that the cord grip is positioned and fastened correctly.
If a 13A (BS 1363) fused plug is used it must be fitted with a 13A fuse. If in doubt consult a
qualified electrician.
Wiring for a 13 Amp Plug (BS1363)
Please note. The Earth Terminal is marked with the letter Eor Earth Symbol.

3
MAIN FEATURES
1. Purification function:
This purifier is equipped with a filter
system, which consists of a HEPA filter,
activated carbon.
HEPA filter captures 99.97% of airborne
particles as small as 0.3 microns.
The filter system can eliminate smoke,
harmful gases (formaldehyde, carbon,
monoxide,etc) and odours, absorb and
decompose harmful bacteria in the air,
thus reducing air pollution and improving
air quality in the home.
2. Negative ion function:
Negative ions are discharged to combine
with dust, bacteria, mildew in the air, and
remove them.
3. Photocatalyst function:
A special filter combined with light
performs a deodorisation of the air
(removing smells not merely disguising
them) and a sterilisation effect reducing
the impact of germs and viruses.

4
PARTS DESCRIPTION
Layer 1- Nano Sliver Pre Filter
Electrostatic Filter can catch duty and powder into filter.
Nano Sliver can restrain germs.
Layer 2-Medicial Class HEPA (Inside)
Removes 99.97% Airborne Particles(@0.3 Micron)
Layer 3- Activate Carbone Filter (Inside)
Get rid of others chemical pollutions, including powder, stinking smell, harmful air.
Layer 4-Photo Catalyst Filter-Tio2 (Back Light Blue)
Photo Catalyst Filter (Tio2) can restrain germs, microbe, bacillus and virus action.
Provide you a healthy life.
Note:
1. The filter can not be washed.
2. Please contact your dealer
should you want to buy a
qualified high efficiency filter.
Handle
Air Outlet
Power Cord
Base
Light Show
Control Panel
Power Cord Storage
UV Lamp
Filter Cover(Air Inlet)
Four Layers High Efficiency Filters
Dust
Germs
smoke
Virus Layer 1 Layer 2 Layer 3 Layer 4
Cleanr
Pure
Clean

5
OPERATION
Light Show
Timer
Power on/off
Fan Speed
Ion and Photocatalyst(TiO2)
Green light when running without Ion / TiO2
Blue light when running Ion / TiO2
1. Ensure filter is unpacked and installed before operation.
(Refer to Installation Instructions Section).
Best performance:
We recommend that you operate your air cleaner 24 hours a day because indoor air can
be quickly contaminated by activity in a room, for example outside air, smoking, and other
air pollutants. While the air cleaner will not process all the air in a room, the more air
circulated through the filter, the more filtered air is returned to the room. Portable air
cleaners will be much more effective in rooms where all doors and windows are closed.
However, for best performance the air outlet slot should be kept clear, at least 1 meter
(three feet) in all directions.
2. Insert the main’s plug into a suitable power socket.
3. Press the POWER button to turn your air cleaner ON, the fan will start at LOW speed.
To turn the air purifier OFF, press the POWER button again. When you turn your Air
Purifier on again the fan will operate at the last speed selected, unless the power was
disconnected.
4. Press the FAN SPEED button to select LOW, MEDIUM or HIGH speed.
5. Your Air Purifier can be turned off by the TIMER after 1, 4 or 8 hours by depressing the
TIMER button. There is an LED to show when the TIMER mode has been selected.
6. The ION and PHOTOCATALYST mode is selected by pressing the ION/TIO2 button.
In this mode your Air Purifier emits negative ions that enhance the air purification
efficiency and provide a fresh air feel to the air. In addition the PHOTOCATALYST mode
helps to prevent viruses, germs and microbes from circulating around the room.
The Control Panel glows BLUE when the ION and PHOTOCATALYST mode is turned on.
When these functions are turned off the control panel glows GREEN.

6
If your air purifier stops working please check the following items first
When unit fails to run:
Is power cord unplugged or the power off?
Is the filter cover not in place?
When the performance seems poor:
Does use for a large space?
Is the filter dirty? Clean it.
Is the inlet or the outlet covered?
Is the machine unsuitable allocation?
When noise occurs:
Is the unit on a flat level surface. Move the machine.
Is the air filter dirty? Clean the filter.
Should there still be a problem, please unplug the unit and contact us.
TROUBLESHOOTING
SPECIFICATIONS
Model: PJ152NP
Power: 51W(High) / 38W(Mid) / 29W(Low)
Ventilation(Cfm): 65(High) / 50(Mid) / 35(Low)
Voltage: 220-240V ~ 50Hz
N.W: 4 Kg(including filter)
G.W: 5 Kg
MAINTENANCE
CAUTION: SWITCH OFF AND DISCONNECT FROM POWER SUPPLY BEFORE SERVICING.
1. To clean the unit use a soft cloth to wipe off any dust. If the unit is very dirty use a damp
cloth. Do not use any cleaning detergents, sprays or any other chemicals as these will
damage the unit. Ensure no water enters into the machine.
2. Replace the HEPA filter when the white surface of HEPA filter turns black, when you
notice that the Carbon Filter is no longer removing the smells or after 6 months.
3. Do not use your unit in areas where there is thick dust or smoke, as this will damage the
filter.

SERVICE AND WARRANTY
If the supply cord is damaged it must be replaced by the Manufacturer or an authorised
service centre in order to avoid a hazard.
For your convenience, record the complete model number and product name (located on
the Product Identification Plate), the date you purchased the product, and attach your
purchase receipt docket as proof of purchase. To ensure your product is covered by
warranty, the complete faulty product together with your purchase receipt should be
returned to your retailer.
ONE (1) YEAR LIMITED WARRANTY
Save This Warranty Information
EHS (International) Ltd. guarantees this product free from defects in materials and
workmanship for a period of one (1) year.
Should this unit be operated under conditions other than those recommended or at
voltages other than the voltage indicated on the unit, or any attempts made to
service or modify the unit, will render this WARRANTY VOID. The product you buy
may sometimes differ slightly from illustration. This warranty is in addition to, and
does not affect, your statutory rights.
Should you have a problem with this product, please call our Help Desk on: (0870)
742 5021.
This product has been manufactured to comply with EEC Directives 73/23/EEC and
89/336/EEC
EHS, Manchester, M17 1RN
EHS 10/09
PREM~I~AIR
EHS, Manchester, UK
Printed in P.R.C.
Table of contents
Other Prem-I-Air Air Cleaner manuals