1. Keep the instrument dry.
2. Keep the instrument and battery out of reach of infants
and children.
3. When the symbol “ ” appears,the batteries are low
and should be replaced. Ensure that battery polarity
connections are correct when replacing batteries. If you are
not using the instrument for a long time, remove the battery.
Ensure that battery polarity connections are correct
when replacing batteries.
If you are not using the instrument for a long time, remove
the battery.
AC WIRE WARNING:
AC WIRE WARNING detection feature works
continuously in Stud scan, Deep scan, and metal scan
modes. When live AC voltage is detected, the AC
detection warning indicator icon will appear in the
display. Use extreme caution under these
circumstances or whenever live AC wiring is present.
• Using the product without instruction
• Using outside the stated limits
• Deactivation of safety systems and removal of explanatory
and hazard labels
• Opening of the equipment by using tools (screwdrivers,
etc.)
• Carrying out modification or conversion of the product
• Use of accessories from other manufacturers without
express approval
Never attempt to repair the product yourself. In case of
damage, contact a local dealer.
Refer to section "Technical data", the device is designed for
using in areas which is habitable for humans.
Do not use the product in explosion hazardous areas or in
aggressive environments.
• To understand the safety instructions on the product and
the instructions in the User Manual.
• To be familiar with local safety regulations relating to
accident prevention.
• Always prevent access to the product by unauthorized
personnel.
This instrument can be used to detect wood stud, metal and
live conductors. It will display signal bar on the center of the
LCD and make a beep sound out when the instrument is
near to the object, which ensures a high level of functional
reliability.
DO NOT ASSUME THESE ARE NO LIVE ELECTRICAL
WIRES IN THE WALL. DO NOT TAKE ACTIONS THAT
COULD BE DANGEROUS IF THE WALL CONTAINS A
LIVE ELECTRICAL WIRE. ALWAYS TURN OFF THE
ELECTRICAL POWER, GAS, AND WATER SUPPLIES
BEFORE PENETRATING A SURFACE. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN
ELECTRICAL SHOCK, FIRE, AND/OR SERIOUS INJURY
OR PROPERTY DAMAGE.
ALWAYS TURN OFF POWER WHEN WORKING NEAR
ELECTRICAL WIRES.
IMPORTANT:
Read before Using EN
The safety instructions and the user manual
should be read through carefully before the
product is used for the first time.
SAFETY INSTRUCTION
PROHIBITED USE
LIMITS OF USE
FUNCTION
AREAS OF RESPONSIBILITY
RESPONSIBILITIES OF THE PERSON IN
CHARGE OF THE INSTRUMENT:
1 2

1. Stud mode indication
2. Metal mode indication
3. AC mode indication
4. AC wire warning
5. ½ in. Scan mode indication
6. 1 in. Scan mode indication
7. 1½ in. Scan mode indication
8. Low battery
A: ½in. Scan Mode: Locates the center and edges of wood
and metal studs up to ½ in. (13 mm) deep
B: 1in. Scan Mode: Locates the center and edges of wood
and metal studs up to ½ in. (25 mm) deep
C: 1½in. Scan Mode: Locates the center and edges of wood
and metal studs up to ½ in. (38 mm) deep
D: Metal Scan: Detects metal (such as ½ inch rebar) up to
2.36 in. (60mm) deep.
E: AC Scan: Detects live unshielded AC wires up to 2 in.
(51mm) deep.
Open the battery compartment
and insert a 9V battery. Pay
attention to the polarity.
Press to turn on/off the device
Press button to switch to the desired mode:
ON/OFF
PRODUCT OVERVIEW
1. INSERT THE BATTERY
2. SWITCHING ON/OFF
3. SELECTING THE MEASUREMENT MODE
A
B
C
F
13
4
7
8
2
6
5
E
D
1
2
1
2
CENTER
Parts Description
A
B
C
D
E
F
Center point system
Mode button
Battery(back of unit)
LCD screen
ON/OFF switch
Scan button
DISPLAY
3 4
OPERATION INSTRUCTION
Change battery when battery symbol is flashing.
It is important to wait for the finishing of calibration
before moving the scanner
ON/OFF
1 sec 1 sec 1 sec 1 sec 1 sec
1
2
1
2

A. Press button to select Stud Scan Mode (½ in, 1 in or
1½).
B. Place the tool against the wall.
C. Calibrate the tool
a. Place the instrument against the surface where you want
to detect before pressing the button.
b. Press the button, the LCD will display in Stud ½ in.
Scan mode.
c. Press the scan button to start calibration, the decreasing
bars will disappear and buzzer will beep on time and the
calibration is completed.
a. Slowly slide tool across surface. A bottom pointed arrow
and EDGE indication will illuminate, indicating location of
the stud edge.
b. Continue sliding tool. When the center of a stud is
located, the full bars on the Signal Strength Indicator, the
pointed arrow on the top of the bars and the CENTER
indication will all show and the buzzer will sound.
D. Move the tool slowly across the surface.
Wallpaper: This wall detector functions normally on walls
covered with wallpaper or fabric, unless the materials are
metallic foil, contain metallic fibers, or are still wet after
application. Wallpaper may need to dry for several weeks
after application.
Freshly painted walls: May take one week or longer to dry
after application
Lath & plaster: Due to irregularities in plaster thickness, it
is difficult for this wall detector to locate studs in Stud
modes. Change to Metal Scan mode to locate the nail
heads holding wood lath to the studs. If the plaster has
metal mesh reinforcement, the wall detector may be unable
to detect through that material.
Extremely textured walls or acoustic ceilings: When
scanning a ceiling or wall with an uneven surface, place thin
cardboard on the surface to be scanned and scan over the
cardboard in Deep mode. If irregular scanning results are
received, switch to Metal Scan mode to locate nails or
drywall screws that line up vertically where a stud or joist is
positioned.
Wood flooring, subflooring, or gypsum drywall over
plywood sheathing: Use Deep mode and move the tool
slowly. The Signal Strength Indicator may only display 1 or
2 bars when the tool locates a stud through thick surfaces.
4. SCANNING DIFFERENT SURFACES
LCD INDICATION WHILE DETECTING
5. MEASURING IN STUD SCAN MODE
1
2
CENTER
1
2
1
2
1
2
1
2
1
2
5 6
A. In cases of deeper studs(thicker walls) where the
center of the stud is located, you can try Stud 1 in. Or
Stud 1½ in. Scan mode.
B. If electric wires or metal or plastic pipes are located
near or in contact with a plaster fibreboard panel, they may
be identified by the wall detector as studs.
ON/OFF
ON/OFF
ON/OFF ON/OFF ON/OFF ON/OFF

A. Press button to select METAL MODE.
B. Hold the tool in the air and Click Scan button, the
decreasing bars will disappear and buzzer will beep on time
and the sensitivity reset is completed. (This will ensure that
it calibrates away from any metal objects and gets highest
sensitivity to metal.)
C. Find the metal at highest sensitivity: Place the tool flat
against the wall and the slide slowly across the surface. The
middle bar will rise up as the tool is getting close to the
metal. Mark the point where you get the highest metal
indication( the top indicated arrow will show up and a steady
beep will sound), Continue in the same direction until
display bars reduce. Reverse direction and mark the spot
where the display bars peak from the reversed direction.
The midpoint of the two marks is the location of the center
of the metal object.
A. Press button to select AC SCAN MODE.
B. Place the tool on the wall and click Scan button, the
decreasing bars will disappear and buzzer will beep on time
and the sensitivity reset is completed.
C. Find the metal at highest sensitivity: Place the tool flat
against the wall and the slide slowly across the surface. The
middle bar will rise up as the tool is getting close to the AC
cable. Mark the point where you get the highest metal
indication( the top indicated arrow will show up and a steady
beep will sound), Continue in the same direction until
display bars reduce. Reverse direction and mark the spot
where the display bars peak from the reversed direction.
The midpoint of the two marks is the location of the center
of the AC cable.
D. Narrow the detecting field: To further pinpoint the
location of the AC cable target, scan the area again. Place
the tool on one of the previous marks and click scan button.
It will reset the tool to a lower sensitivity and narrow the
scan area.
E. Scan in both directions and repeat the step C and D until
the AC cable is located precisely.
Note: AC Scan will only detect live(hot) unshielded AC
wiring. Please refer to the AC WIRE WARNING for more
important details and warnings about AC detection.
D. Narrow the detecting field: To further pinpoint the
location of the metal target, scan the area again. Place the
tool on one of the previous marks and click scan button. It
will reset the tool to a lower sensitivity and narrow the scan
area.
E. Scan in both directions and repeat the step C and D until
the metal is located precisely.
Note: If any bars display on the screen, metal is
present. Small targets or targets deep within the
surface may only illuminate some of the bars and not
the center line or audio tone. In this case, use the
highest indication to determine the metal position.
6. MEASURING IN METAL MODE. 7. MEASURING IN AC WIRE MODE.
7 8
ON/OFF ON/OFF
ON/OFF
Figure A Figure B
Figure C
Technical specifcation
Power supply 1 x 9V alkaline battery
Weight(battery not included)
Dimension 3*7*16cm
142
Measuring depth
Metal
Metal or wood Stud
Non-magnetic metal
Charged wire 100-230 volts
80mm
2in. (50mm)
1) 1/2 in(13mm)
2) 1 in.(25mm)
3) 3/2 in.(38mm)
2.36in. (60mm)

The batteries must not be disposed with household waste.
Care for the environment and take them to the collection
points provided in accordance with national or local
regulations.The product must not be disposed with
household waste.Dispose of the product appropriately in
accordance with the national regulations in force in your
country. Adhere to the national and country specific
regulations.Product specific treatment and waste
management can be downloaded from our homepage.
The Instrument PWDX-F38 has a two-year warranty. For
further information on this, contact your dealer.This
warranty is void if product is used for commercial purposes.
This warranty is not transferable and does not cover
products damaged by misuse, neglect, accident, alterations
or use and maintenance other than that specified in the
owner's manual. This warranty does not apply to any
expendable parts that can wear from normal use. This
warranty excludes any accessories.
9
DISPOSAL
WARRANTY
CAUTION
www.prexiso-eu.com