3
Wiring the Floodlight
• Ensure that the mains supply is isolated before commencing installation.
• A suitable rated connector must be used to connect the lead from the oodlight to
the mains supply.
• Connect the mains cable to the connector. Ensure that the correct polarities for
Live, Neutral and Earth are observed i.e.
- Green/yellow - Earth terminal
- Brown - Live terminal
- Blue - Neutral terminal
After wiring, check that there are no stray strands and that all the wires have been
correctly installed.
• Before connecting power, perform the electrical tests specied in the current
Building and IET Wiring Regulation to ensure that the installation is safe and that
the wiring has been performed correctly.
• Restore the mains power supply and check that the oodlight illuminates the
required area. Tighten the oodlight using the bolts on the brackets.
CLEANING & MAINTENANCE
• Clean the oodlight only with a soft dry cloth. Do not use any chemicals, abrasives
or solvents that could damage the oodlight.
• The oodlight has a sealed LED lamp and is maintenance free. The LED lamp
cannot be replaced. When the LED lamp reaches the end of its life, the oodlight
will have to be replaced.
SPECIFICATION
Model PELL0290 PELL0291 PELL0292 PELL0293 PELL0294
Cable Length 1m 1m 1m 1m 1m
Input Voltage 220-240V
AC 50Hz
220-240V
AC 50Hz
220-240V
AC 50Hz
220-240V
AC 50Hz
220-240V
AC 50Hz
Luminous ux 680lm 1380lm 2100lm 3600lm 7500lm
Wattage 10W 20W 30W 50W 100W
Beam angle 120° 120° 120° 120° 120°
Dimmable No No No No No
Nominal lifetime
25,000h 25,000h 25,000h 25,000h 25,000h
Light source SMD2835 SMD2835 SMD2835 SMD2835 SMD2835
Colour
temperature 6000K 6000K 6000K 6000K 6000K
Ingress rating IP65 IP65 IP65 IP65 IP65
Earthing Class I Class I Class I Class I Class I
Weight 0.23kg 0.29kg 0.46kg 0.61kg 1.1kg
Dimensions
WxHxD (mm) 131x87x40 157x111x44
205x142x49 235x170x53 310x220x63
These products contain a light source of energy eciency class F