Pro-face GP3000 Series User manual

1
Preface
Thank you for purchasing the Pro-face GP3000 series RGB Input Unit, “GP3000-
RGB201” (hereafter referred to as the “RGB unit”).
This unit is intended for use with the expansion unit interface of the Pro-face
GP3000 series*1 programmable operator interface (hereafter referred to as the
“Display unit”), and as a RGB input interface with any of the above mentioned
Display units.
Before using the RGB unit, please be sure to read this manual and other related
manuals to fully understand all the settings and functions.
*1 For the compatible models, please refer to the following.
© 2009 Digital Electronics Corporation. All rights reserved.
Product names used in this manual are the trademarks / registered trademarks of
their respective owners.
SEE
Applicable Products (page 5)
NOTICE
1. Copying this manual’s contents, either in whole or in part, is prohibited
without the express permission of Digital Electronics Corporation, Japan.
2. The information contained in this manual is subject to change without notice.
3. If you find any errors or omissions in this document, please contact Digital
Electronics Corporation to report your findings.
4. Please be aware that Digital Electronics Corporation shall not be held liable
by the user for any damages, losses, or third party claims arising from the
uses of this product.

2
Essential Safety Precautions
All safety-related procedures stated in this document must be followed to operate
the RGB unit correctly and safely. Be sure to read this manual and any related
documents thoroughly to understand the correct operation and functions of the
RGB unit.
Safety Icons
Throughout this manual, these icons provide essential safety information for RGB
unit operation procedures requiring special attention. These icons indicate the
following levels of danger:
General Safety Precautions
Indicates situations where death, severe injury, or
major equipment damage can occur.
Indicates situations where slight injury or minor
equipment damage can occur.
Indicates actions or procedures that should NOT be
performed.
Indicates actions or procedures that MUST be
performed to ensure correct unit operation.
Due to the possibility of an electrical shock, be sure to unplug the Display
unit’s power supply prior to installing the RGB unit.
Be sure to design your system so that a communication faultbetween Display
unit and external device (PLC, etc.) will not cause equipment to malfunction.
This is to prevent any possibility of injury or equipment damage.
Do not modify the RGB unit. Doing so may cause a fire or an electric shock.
Do not allow water, liquids, or metal particles to enter into the RGB unit’s
case, otherwise it can cause a malfunction or electrical shock.

3
Unit Disposal
Usage Precautions
• When using RGB signal input, a blue background may appear momentarily
while the screen is adjusted or when a PC screen is switched. This
phenomenon is normal and the RGB unit is not malfunctioning.
• With some types of RGB signals, the displayed images or RGB output images
may contain noise or may blur during the screen adjustment. It is possible that
these problems cannot be adjusted completely, given the RGB unit's available
range of adjustment.
• When images without the supported resolution or refresh rate are input, a blue
background screen will appear.
• Use a RGB cable with a connector of 18 mm (0.71 in.) or less in thickness.
• Use a USB cable with a connector of 8.5 mm (0.33 in.) or less in thickness.
• Turn the PC power off before removing the USB cable. Removal of the USB
cable while the electricity is on may result in unstable PC operation.
When the USB cable is disconnected, reboot the PC.
Avoid storing or operating the RGB unit in locations where it will be exposed
to direct sunlight, high temperature, excessive dust, or vibration.
Avoid storing or operating the RGB unit in locations where large and sudden
temperature changes can occur, possibly causing condensation.
Do not store or operate the RGB unit where chemicals can evaporate, be
present in the air and adhere to the unit.
Since the RGB unit is a precision instrument, do not store or operate it in
locations where strong physical contact or excessive vibration can occur.
Do not use paint thinner or organic solvents to clean the outside of the RGB
unit. Instead, soak a soft cloth in a diluted neutral detergent, wring it tightly
and then wipe the unit’s outside case.
When the RGB unit is disposed of, it should done so according to your
country’s regulations for similar types of industrial waste.

4
Information Symbols
This manual uses the following icons:
Package Contents
This unit has been carefully packed, with special attention to quality. However,
should you find anything damaged or missing, please contact your local distributor
immediately.
Indicates that failure to follow the instructions given with this
icon may cause the RGB unit to malfunction or data to
disappear.
Contains additional or useful information on operations.
(1) (2) Indicates procedure steps.
Be sure to follow these procedures in the order they are written.
* Indicates the description of footnote in the text.
Indicates pages containing related information or related
manuals.
GP-Pro EX Indicates the Screen editor software for the Pro-face GP3000
series.
SEE
Hardware Manual <This Manual> (1)
Warning/Caution Information (1)
Driver CD (1)
Fixing Screws (4)
RGB unit (1)
USB Cable Holder (mini-B) 1 set
(USB Holder (2)) (USB Holder Fixing Screws (2))

5
Applicable Products
Applicable Units
Applicable Software
*1The software version information can be found on the [Help] menu's [Version
Information] selection.
Inquiry
Do you have any questions or comments about this product?
Please access our website anytime if you need a help for the solution.
http://www.pro-face.com/otasuke/
When you visit the above website for the first time, please see the “Contact
Pro-face” site for inquiry.
GP3000 Series AGP-35*0T, AGP-36*0T, AGP-37*0T
GP3000 Series GP-Pro EX Ver. 2.50 or later *1
• For GP3000 Series, GP-Pro EX Ver. 2.50 or later*1 is required
to utilize the RGB unit.
If you are currently using an earlier version of the above
software, you will need to upgrade it. For more information,
please contact your local Pro-face distributor.

6
UL/c-UL Approval
The RGB unit "GP3000-RGB201" is a UL/c-UL product, listed on UL File
No.E220851 and UL File No.E210412.
The RGB unit "GP3000-RGB201" is a UL/c-UL product, recognized on UL File
No.E171486 and UL File No.E231702.
The RGB unit "GP3000-RGB201" conforms to the following standards:
• UL508
Standard for Industrial Control Equipment
• UL60950-1
Information Technology Equipment - Safety - Part 1:General requirements
• ANSI/ISA-12.12.01-2007
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and
Class III, Division 1 and 2 Hazardous (classified) Locations.
<Cautions>
Be aware of the following items when building the Display unit into an end-use
product:
• Be sure that the unit is installed so that it is at least 100 mm away from
any adjacent structures or devices. If these requirements are not met,
the heat generated by the unit's internal components may cause the
unit to fail to meet UL standard requirements.
• For use with the following models only: Models 3280024-02, -14;
3280035-41.
• For use with the following models only: Models 3280024-01, -11, -13;
3280035-45, -75; 3581301-01, -03.
• Receivable signals are only from isolated secondary source.
• RGB input interface circuitry is not intended to be directly connected to
a source greater than 30 volts and the available current greater than 5
mA.
<
ANSI/ISA-12.12.01-2007 - Compliance and Handling Cautions
>
• Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous
Locations, or Non-Hazardous Locations.
• WARNING: Explosion hazard - substitution of components may impair
suitability for Class I, Division 2.
Product Model No. UL/c-UL Registration Model No.
GP3000-RGB201 3710013-01

7
• WARNING: Explosion hazard - when in hazardous locations, turn off
power before replacing or wiring modules.
• WARNING: Explosion hazard - do not disconnect equipment unless
power has been switched off or the area is known to be non-hazardous.
CE Marking
The RGB unit “GP3000-RGB201” is a CE marked product that conforms to EMC
directives, EN55011 Class A and EN61000-6-2.

8

9
Table of Contents
Preface....................................................................................................1
Essential Safety Precautions...................................................................2
Information Symbols................................................................................4
Package Contents ..................................................................................4
Applicable Products.................................................................................5
Inquiry......................................................................................................5
UL/c-UL Approval....................................................................................6
CE Marking..............................................................................................7
Table of Contents ....................................................................................9
Chapter 1 Overview
1.1 Operating the RGB Unit............................................................. 11
1.2 System Configuration ................................................................11
1.2.1 Connection Configuration Diagram......................................11
1.3 Part Names and Functions........................................................12
1.4 Unbundled Items........................................................................13
1.5 Software.....................................................................................13
Chapter 2 Specifications
2.1 General Specifications...............................................................15
2.1.1 Electrical..............................................................................15
2.1.2 Environmental......................................................................15
2.1.3 Structural .............................................................................16
2.2 Performance Specifications.......................................................17
2.2.1 Performance Specifications.................................................17
2.2.2 Interface Specifications........................................................19
2.3 External View and Dimensions..................................................21
2.3.1 External View.......................................................................21
2.3.2 GP-3500 Series External View with the RGB Unit...............22
2.3.3 GP-3600 Series External View with the RGB Unit...............23
2.3.4 GP-3700 Series External View with the RGB Unit...............24
Chapter 3 Installation
3.1 Installing the RGB Unit ..............................................................25
3.2 Wiring for RGB and USB Cable.................................................27

10
3.2.1 RGB Cable Connection.......................................................27
3.2.2 USB Cable Connection ....................................................... 27
Chapter 4 Setup
4.1 RGB IN0/1 Display Adjustment ................................................. 31
4.2 Setup Mouse Emulation ............................................................ 31

GP3000 Series RGB Input Unit Hardware Manual
11
Chapter 1 Overview
1.1 Operating the RGB Unit
The RGB unit features the following functions:
• Maximum of 2 screens can be displayed on the Display unit among 2 PC
image (RGB) inputs.
• Images on the Display unit are captured and saved on the CF card in
JPEG files.
1.2 System Configuration
1.2.1 Connection Configuration Diagram
The following diagram illustrates the connection.
*1 The expansion unit cannot be installed in the Display unit expansion
unit Interface (EXT1) if the RGB unit is installed in AGP-35*0T.
Display unit
1)
VM BUS
2) USB (0 to 1)
3) RGB IN (0 to 1)
Connects to the Display unit rear face VM unit I/F
Connect with a USB cable (optional or commercially available)
Connect with a RGB cable (optional or commercially available)
1)
2)
3)
RGB unit
*1
PC
(PS-2000B, PL-3000B, etc.)

Chapter 1 Overview
12
1.3 Part Names and Functions
A. RGB IN (RGB0, RGB1)
Connectors (2 ports) to input PC
images.
PC images of 2 systems (RGB0 and
RGB1) can be input.
B. Connecting port for Display unit
Connector for the VM Unit Interface
of Display unit.
C. USB (mini-B type) (USB0, USB1)
Connectors (2 ports) for mouse
emulation.
D. SW1
System setting switch (Default ON)
• When performing mouse emulation, be aware of the
following items.
• Download the mouse emulation software (UPDD) from
Pro-face website, "OtasukePro!" and install.
http://www.pro-face.com/otasuke/
• Connect to PC using USB0 and RGB0 or USB1 and
RGB1 combination.
Rear
A
B
Front
D
Side
C
ON
1 2 3 4
Switch Description Setting
1 Reserved (always ON) -
2 Reserved (always ON) -
3 Reserved (always ON) -
4 Reserved (always ON) -

GP3000 Series RGB Input Unit Hardware Manual
13
1.4 Unbundled Items
Cable
Maintenance Items
1.5 Software
The RGB unit is compatible with GP-Pro EX Ver. 2.50 or later (GP3000
series).
Depending on your software version, it is necessary to download the latest
module and install the additional programs.
For details, please access Pro-face's website "OtasukePro!" for product
support.
http://www.pro-face.com/otasuke/
Refer to the “GP-Pro EX Reference Manual” for details on display settings
for the input image window.
Product Name Model No. Description
RGB Cable FP-CV02-45 RGB cable for outputting an
image signal from the various
hosts to the Display unit.
(4.5m)
USB Cable CA9-USBAMB/5M-01 USB cable for mouse
emulation (5m)
Product Name Model No. Description
USB Cable
Holder (mini-B) CA9-USBATRGB/MB-01 USB cable retaining holder.
(1 set)

Chapter 1 Overview
14

GP3000 Series RGB Input Unit Hardware Manual
15
Chapter 2 Specifications
2.1 General Specifications
2.1.1 Electrical
2.1.2 Environmental
Items Specifications
Power
Supply
Rated Voltage DC5V 5% (supplied by the Display unit)
Power
Consumption DC5V 0.8A (max.)
Voltage Endurance
DC type Display unit:
AC1000V 20mA for 1 minute
(between charging and FG terminals)
AC type Display unit:
AC1500V 20mA for 1 minute
(between charging and FG terminals)
Insulation Resistance DC500V 10MΩ (min.)
(between charging and FG terminals)
Items Specifications
Physical
Surrounding Air
Temperature 0 to 50°C
Storage
Temperature -20 to +60°C
Ambient Humidity 10 to 90% RH
(Wet bulb temperature: 39°C max.
- no condensation.)
Storage Humidity 10 to 90%RH
(Wet bulb temperature: 39°C max.
- no condensation.)
Dust 0.1mg/m3and below
(non-conductive levels)
Pollution Degree For use in Pollution Degree 2 environment
Atmosphere Free of corrosive gases
Air Pressure
Vibration
Resistance
(altitude range)
800 to 1114hPa
(2000 meters above sea-level maximum)
±

Chapter 2 Specifications
16
2.1.3 Structural
Mechanical
Vibration
Resistance
IEC61131-2 compliant
5 to 9Hz single-amplitude 3.5mm [0.14 in.]
9 to 150Hz constant-accelerated velocity 9.8m/s2
X,Y,Z directions for 10 cycles (100 minutes)
Concussion
Resistance IEC61131-2 compliant
(147m/s2 X, Y, Z directions for 3 times)
Electrical
Noise Immunity
Noise Voltage: 1000Vp-p (Display unit: DC type)
1500Vp-p (Display unit: AC type)
Pulse Duration: 1µs
Rise Time: 1ns
(via noise simulator)
Electrostatic
Discharge
Immunity Contact Electrical Discharge
6kV (complies with IEC61000-4-2 Level 3)
Items Specifications
Installation
Installation
method Screw fixing
Cooling Method Natural air circulation
Weight Approx. 400g [0.9lb] or less
External
Dimensions
W110mm [4.33in.] x H144mm [5.67in.] x
D27mm [1.06in.]
(excluding projection and connector part)
Items Specifications

GP3000 Series RGB Input Unit Hardware Manual
17
2.2 Performance Specifications
2.2.1 Performance Specifications
RGB Input (RGB IN0/1)
Items Specifications Remarks
Signal System VESA standard
Analog RGB, separated -
Maximum
Transmission
Distance
5m or less is recommended Varies depending on
the performance of the
PC connected.
Display Colors 262,144 Colors -
Resolution
See PC Signal input Screen Mode.
-
Color Signal 0.7Vp-p, Positive polarity (TYP)
Input range: 0.5 to 1.0Vp-p,
Positive polarity 75Ω termination resistor
Horizontal
Sync. TTL level,
positive true / negative true
Signal polarity is
determined
automatically.
Vertical Sync. TTL level,
positive true / negative true
Signal polarity is
determined
automatically.
No. of Interface 2 -
Connector
(Main Unit) D-sub 15 pin (Socket) -
SEE
PC Signal Input Screen
Mode (page18)

Chapter 2 Specifications
18
PC Signal Input Screen Mode
Inputting the signal, the frequency of which deviates by more than 5% from
the frequency listed above, may result in distortion of pictures.
USB
The PC recognizes the USB port as a virtual Com port.
Mode Horizontal
Resolution Vertical
Resolution H. Sync.
(kHz) V. Sync.
(Hz) Dot Clock
(MHz)
VGA
640 480 31.469 59.940 25.175
640 480 37.861 72.809 31.500
640 480 37.500 75.000 31.500
640 480 43.269 85.008 36.000
SVGA
800 600 35.156 56.250 36.000
800 600 37.879 60.317 40.000
800 600 48.077 72.188 50.000
800 600 46.875 75.000 49.500
800 600 53.674 85.061 56.250
XGA 1024 768 48.363 60.004 65.000
1024 768 56.476 70.069 75.000
1024 768 60.023 75.029 78.750
Items Specifications Remarks
Communication baud rate 9600bps
Data length 8 bit
Parity bit None
Stop bit 1 bit
Flow control None
±

GP3000 Series RGB Input Unit Hardware Manual
19
2.2.2 Interface Specifications
RGB Input Interface
D-sub 15 pin connector for RGB Input
<Cable Side>
RGB connector Pin Assignments
Recommended Cables FP-CV02-45 (made by Pro-face)
Pin
No. Signal Name I/O Condition Pin Assignment
1RIN I
Analog R
2GIN I
Analog G
3BIN I
Analog B
4 VGA_ID0 - No connection
5 AGND - Analog Ground
6 RGND - Analog Ground
7 GGND - Analog Ground
8 BGND - Analog Ground
9PLUG -+5V
10 GND - Ground
11 VGA_ID2 - No connection
12 DDCSDA I/O DDC Data
13 HSYNC I Analog Hsync
14 VSYNC I Analog Vsync
15 DDCSCL I DDC Clock
• Connect the cables before starting up the PC and the Display
unit. To prevent possible equipment malfunction, do not
disconnect the cable while the equipment is turned ON.
• If a cable other than the specified Pro-face RGB cable is
used, the product performance cannot be guaranteed against
possible noise or signal degradation.
15 5
1
11

Chapter 2 Specifications
20
USB Interface
USB connector for Mouse Emulation (mini-B)
<Cable Side>
USB connector Pin Assignments
Recommended Cables CA9-USBAMB/5M-01 (made by Pro-face)
Pin
No. Signal Name I/O Condition Pin Assignment
1 Vbus I 5V Detection
2 -Data (D-) I/O USB Differential
Signaling -
3 +Data (D+) I/O USB Differential
Signaling +
4 ID - No connection
5 GND - Ground
• Connect the cables before starting up the PC and the Display
unit. To prevent possible equipment malfunction, do not
disconnect the cable while the equipment is turned ON.
• If a cable other than the specified Pro-face USB cable is used,
the product performance cannot be guaranteed against
possible noise or signal degradation.
1 5
Other manuals for GP3000 Series
6
This manual suits for next models
1
Table of contents
Other Pro-face Industrial Monitor manuals
Popular Industrial Monitor manuals by other brands

JCM Technologies
JCM Technologies V-LCD user manual

3M
3M Dynapro ET 355 Monitor HL Installation Manual Addendum

Hope Industrial Systems
Hope Industrial Systems HIS-ML21-SGAB user manual

Pepperl+Fuchs
Pepperl+Fuchs DA5-IU-C operating instructions

Acnodes
Acnodes APW 5220 user manual

Raven
Raven RGL 600 Operation manual