Proedrou Drakaki 11 ,173 41 Agios Dimitrios
Call center: 210 9850 244, Fax: 210 9823 264
www.profelmnet.com
Functions and connections
Power supply
230V:
Supply the control
panel with
230Vac.Check that the
yellow indication light
is ON. Press the button
of the transmitter and
check the red
indication light is ON
(receiver).
Clear memory:
The first step is to clear
the control panel
memory. Press the
button CODE of the
control panel and the
RED indication light
goes ON after a while. Keep it pressed until the RED indication light
goes OFF. The memory is now clear.
Adding a new transmitter with the control panel
button:
Press the CODE button and the RED indication light goes ON (after
a small delay). Leave it and during the next 3 seconds, press the
desired transmitter channel button until the RED indication light
blinks and goes OFF. The new transmitter is saved. Follow the same
procedure to program more (up to 300) new transmitters.
Working time:
Adjustable from 1-180S. While the gate is fully closed, press and
keep the TIME button of the control panel pressed until the gate
goes to fully open position. Then leave it. The working time is
saved.
Adding a new transmitter remotely:
The motor is fully closed or open. Press a working transmitter
button (already in memory) to start the motor working and hold it
pressed until the motor stops. When it stops, leave it and press the
new transmitter button immediately. The new transmitter is saved.
Repeat steps to program more transmitters remotely. When the
memory is full (300 transmitters) you cannot add more new
transmitters.
Pedestrian function:
When the pedestrian traverses the gate, the gate will open for a
while and then automatically will close. Photocells need to be
installed. The time of closing is the same with the second time of
A/C.
Photo-cell connection:
Connect the photocell contact and power supply 24VAC according
to the diagram in the right. When you finish, put the program
dipswitch 5 in ON position.
Photocell operation: When the door closes and the photocell
beam is cut-off, the door stops immediately and automatically
activates the open function. If the photocell beam is cut-off, the
door never closes.
Blinker light function:
The blinker light gives a permanent voltage of 230V / 10W, connects
to terminals 1 & 3 and operates as long as the gate is moving. If
you want to flashes for more time, eg 100 seconds, then program
100-second for the working time of the control panel.
Adjusting the auto close time:
There is a double counter in the A/C function. The first one is 120
seconds and is applied when the door stops after an open function.
During this counting time of 120 sec., if the photocell beam is
disturbed, then after the beam is free, the A/C counting time
becomes 10 sec. until the fully closed position. In this control panel,
the second counting time of 10 sec., can be regulated. Press the
TIME button, keep it pressed and within 1 sec. , press the CODE
button. The red indicating light starts flashing, indicating the
seconds of the counter. The time of the counter is from 1-120
seconds. Keep it pressed for the time you wish to give in A/C and
pedestrian function. The dipswitch 3 needs to be ON.
Indication light LED:
There are indication LED lights that displays the different functions
of the control panel for the photocells.
Reset the
automation:
Case of malfunction,
please remove the
power supply (230Vac)
for 10 seconds,
reconnect and recheck.
Compatible
transmitters:
Based on the model you
have, select the
appropriate transmitter.