manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Profelmnet
  6. •
  7. Control Panel
  8. •
  9. Profelmnet 3029 User manual

Profelmnet 3029 User manual

Proedrou Drakaki 11 ,173 41 Agios Dimitrios
Call center: 210 9850 244, Fax: 210 9823 264
www.profelmnet.com
3029
Control panel for rolling shutters up to 1200watt
Code
Frequency
Codification
Terminal
Switches
Photocell
s
Ext.Butto
n
Auto close
Light
230V
Motor
torque
Slow
move
Reverse
move
Memory
PSR/PTR - 3029
433,92/868,3
Keeloq
Rolling
YES
YES
YES
YES
YES
NO
NO
YES
300
PS-3029
433,92
Standard
YES
YES
YES
YES
YES
NO
NO
YES
300
PN-3029
433,92
Profelmnet
Rolling
YES
YES
YES
YES
YES
NO
NO
YES
300
Covering distance: from 30 –100 μ. depends on external
conditions.
Νο
Function description
1
Not used
2
Not used
3
AUTO-CLOSE FUNCTION
OFF: No auto close
ON: Auto-close. Embedded auto close function. Works with
the photocell. When the gate opens and there is no access
(no obstacle detection from the photocell), the A/C time is
120 seconds (the gate will close after 120 seconds). If there is
access and obstacle detection from the photocell, then the
A/C time is 10 seconds (the A/C timer counts 10 seconds after
the photocell is free and then the gate will automatically
close). The second time of A/C can be changed (follow the
below instructions).
4
Not used.
5
PHOTOCELLS
OFF: NO photocells.
ON: Photocells. The power supply of the photocell 24VAC in
terminals 13&14 and COM & NC of the photocell in terminals
8 & 9.
6
Not used
7
MOTOR REVERSION
OFF/ON: The first move of the motor needs to be opening,
after the power of control panel. When the first move is
closure, switch the dipswitch 7 to the opposite position.
8
Not used
Check all connections. Check the terminal switches of the motor. The BLUE/GREY (common) motor wire is connected in terminal 4. Earth motor
wire is not connected in the control panel.
PHOTOCELL
TRANSFORMER
V - 1,5VA12
TRANSFORMER
24V - 1,5VA
CODE ΧΡΟΝΟΣ
REEI VER
PROGRAMMS
1 2 3 4 5 6 7 8
ON
FUSE 5Α
RECEIVER RF
FLASH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
M
L I V E
NEUTRAL
COMMON
START/STOP
PHOTO
ANTENNA
OPEN
CLOSE
230VAC 24VAC
60mA
COMMON
230V
Proedrou Drakaki 11 ,173 41 Agios Dimitrios
Call center: 210 9850 244, Fax: 210 9823 264
www.profelmnet.com
Functions and connections
Power supply
230V:
Supply the control
panel with
230Vac.Check that the
yellow indication light
is ON. Press the button
of the transmitter and
check the red
indication light is ON
(receiver).
Clear memory:
The first step is to clear
the control panel
memory. Press the
button CODE of the
control panel and the
RED indication light
goes ON after a while. Keep it pressed until the RED indication light
goes OFF. The memory is now clear.
Adding a new transmitter with the control panel
button:
Press the CODE button and the RED indication light goes ON (after
a small delay). Leave it and during the next 3 seconds, press the
desired transmitter channel button until the RED indication light
blinks and goes OFF. The new transmitter is saved. Follow the same
procedure to program more (up to 300) new transmitters.
Working time:
Adjustable from 1-180S. While the gate is fully closed, press and
keep the TIME button of the control panel pressed until the gate
goes to fully open position. Then leave it. The working time is
saved.
Adding a new transmitter remotely:
The motor is fully closed or open. Press a working transmitter
button (already in memory) to start the motor working and hold it
pressed until the motor stops. When it stops, leave it and press the
new transmitter button immediately. The new transmitter is saved.
Repeat steps to program more transmitters remotely. When the
memory is full (300 transmitters) you cannot add more new
transmitters.
Pedestrian function:
When the pedestrian traverses the gate, the gate will open for a
while and then automatically will close. Photocells need to be
installed. The time of closing is the same with the second time of
A/C.
Photo-cell connection:
Connect the photocell contact and power supply 24VAC according
to the diagram in the right. When you finish, put the program
dipswitch 5 in ON position.
Photocell operation: When the door closes and the photocell
beam is cut-off, the door stops immediately and automatically
activates the open function. If the photocell beam is cut-off, the
door never closes.
Blinker light function:
The blinker light gives a permanent voltage of 230V / 10W, connects
to terminals 1 & 3 and operates as long as the gate is moving. If
you want to flashes for more time, eg 100 seconds, then program
100-second for the working time of the control panel.
Adjusting the auto close time:
There is a double counter in the A/C function. The first one is 120
seconds and is applied when the door stops after an open function.
During this counting time of 120 sec., if the photocell beam is
disturbed, then after the beam is free, the A/C counting time
becomes 10 sec. until the fully closed position. In this control panel,
the second counting time of 10 sec., can be regulated. Press the
TIME button, keep it pressed and within 1 sec. , press the CODE
button. The red indicating light starts flashing, indicating the
seconds of the counter. The time of the counter is from 1-120
seconds. Keep it pressed for the time you wish to give in A/C and
pedestrian function. The dipswitch 3 needs to be ON.
Indication light LED:
There are indication LED lights that displays the different functions
of the control panel for the photocells.
Reset the
automation:
Case of malfunction,
please remove the
power supply (230Vac)
for 10 seconds,
reconnect and recheck.
Compatible
transmitters:
Based on the model you
have, select the
appropriate transmitter.

This manual suits for next models

4

Other Profelmnet Control Panel manuals

Profelmnet 3033 User manual

Profelmnet

Profelmnet 3033 User manual

Profelmnet 3029 User manual

Profelmnet

Profelmnet 3029 User manual

Profelmnet 3033 User manual

Profelmnet

Profelmnet 3033 User manual

Profelmnet 3433 User manual

Profelmnet

Profelmnet 3433 User manual

Profelmnet 2114 User manual

Profelmnet

Profelmnet 2114 User manual

Popular Control Panel manuals by other brands

Schenck process Intecont Tersus Beltweigher instruction manual

Schenck process

Schenck process Intecont Tersus Beltweigher instruction manual

Halma Ampac ZoneSense Plus Manua

Halma

Halma Ampac ZoneSense Plus Manua

Wenzel HT 400 RC user manual

Wenzel

Wenzel HT 400 RC user manual

Global Streams CS-1000 user guide

Global Streams

Global Streams CS-1000 user guide

AERMEC FMT 10 Use and installation  manual

AERMEC

AERMEC FMT 10 Use and installation manual

Honeywell CM737 User instruction

Honeywell

Honeywell CM737 User instruction

Casablanca Adapt Touch W-52 instructions

Casablanca

Casablanca Adapt Touch W-52 instructions

tau D747M installation guide

tau

tau D747M installation guide

Volvo Penta EVCEC-C3 Calibrations and Settings

Volvo Penta

Volvo Penta EVCEC-C3 Calibrations and Settings

IDS X Series Installer manual

IDS

IDS X Series Installer manual

Beijer Electronics QTERM-IV user manual

Beijer Electronics

Beijer Electronics QTERM-IV user manual

Tennant IPC PW-H101 instruction manual

Tennant

Tennant IPC PW-H101 instruction manual

SKYDANCE T15 manual

SKYDANCE

SKYDANCE T15 manual

Roland UA-S10 manual

Roland

Roland UA-S10 manual

AKO 15640 user manual

AKO

AKO 15640 user manual

Ravel RE -102 Installation, commissioning & operating  manual

Ravel

Ravel RE -102 Installation, commissioning & operating manual

Sunricher SR-2201 manual

Sunricher

Sunricher SR-2201 manual

Siemens SINAMICS S120 operating instructions

Siemens

Siemens SINAMICS S120 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.