manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Profelmnet
  6. •
  7. Control Panel
  8. •
  9. Profelmnet 2114 User manual

Profelmnet 2114 User manual

Ag.Dimitriou 286A ,173 42 Agios Dimitrios
Call center: 210 9850 244, Fax: 210 9823 264
www.profelmnet.com
2114
Control panel for double motors up to 1600 watt
GND L N
230VAC Φάρος
230VAC
Motor
1
Κεραία
0 +
12V
Πυκνωτής Πυκνωτής
κοινό
κλείσιμο
άνοιγμα
κοινό
κλείσιμο
Motor
2
'
κ
V
λειδαριά
12
κοινό
κοινό
Φώτο2
Φώτο 1
φωτοκύτταρα
1+2
1
εξωτερικά μπουτόν
Τερματικοί διακόπτες
κλειστό
ανοικτό
κοινό
κλειστό
κοινό
ανοικτό
Mοτέρ 1 Mοτέρ 2
άνοιγμα
Προγράμματα
1 8
Τροφοδοσία Kωδικός
Χρόνος διαδρομής
M1 M2
Κωδικός
Ενδεικτικά
1 2 3 4 5 6
Ενδεικτικά λειτουργίας
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
24 25 26 27 28 29
Δύναμη μοτέρ
Χρόνος αργού
+
+
”
”
Ï
1 2 3 4 5 6 7 8
ON
Code
Frequency
Codification
Terminal
Switches
Photocells
Ext.Button
Auto close
Light
230V
Motor
torque
Slow move
PSR/PTR-2114
433,92/868,3
Keeloq roll
YES
YES
YES
YES
YES
YES
YES
PS-2114
433,92
Standard
YES
YES
YES
YES
YES
YES
YES
PSR/PTR-2114P
433,92/868,3
Profelmnet roll
YES
YES
YES
YES
YES
YES
YES
Νο
Function description
1
OFF: NO terminal switches. In case of single swing gate or
rolling shutter.
ON: Terminal switches. In case of sliding gate or barrier.
2
OFF: No photocell 2.
ON: Photocell 2. (Internal 1m after the fully open position to
stop the motion.)
3
OFF: No photocell 1.
ON: Photocell 1. (On the door for safety and auto-close.)
4
OFF: No auto close
ON: Auto-close. There is a double counter in the A/C
function. The first one is 120 seconds and is applied when
the door stops after an open function. During this counting
time of 120 sec., if the photocell beam is disturbed, then
after the beam is free, the A/C counting time becomes 10
sec. until the fully closed position.
5
OFF: No delay between two motors.
ON: Delay between Motor 1 (first) and Motor 2 (second)
6
OFF:NO repeatable close.
ON: Repeatable close for 1 sec every 1 hour
7
OFF: No key-lock
ON: Key-Lock (activates the key-lock routine)
8
OFF: NO Light flash
ON: Light FLASH (OFF), or constant 2min. (ΟΝ)
Check all connections. Check the terminal switches of the motor. The BLUE/GREY motor wire is connected in terminal 4.
Ag.Dimitriou 286A ,173 42 Agios Dimitrios
Call center: 210 9850 244, Fax: 210 9823 264
www.profelmnet.com
Functions
Motor torque for both:
Adjust the motor torque for both motors at ½ of the
total torque.
Power supply 230V:
Supply the control panel with 230V.Check that the yellow indication
light is ON. Press the button of the transmitter and check the red
indication light is ON. The first shutter move after power-up (230V)
is the OPEN direction, otherwise substitute open/close motor
wires.
Working time:
BOTH SECTIONS OF THE DOOR ARE FULLY CLOSED. Press
MOTOR TIMER button M1 and keep it pressed until the first door
section goes into the fully OPEN position, and leave it
immediately. Press MOTOR TIMER button M2 for the second
section of the swing door and also keep it pressed until the fully
OPEN position too. Remove power; place both sections in the fully
closed position and power up.
Motor direction (open-close):
The MOTOR 1 (K7-8-9) is the motor that starts first from the
closure position of the gate. After all connections are completed,
move the both motors in the middle of the route manually. Power
the control panel with 230V. Using the button of timer M1 and
M2, check the indication lights to be ON. The movement of the
motors needs to be compatible with the function OPEN-CLOSE.
If not, turn the wires of the motor CLOSE-OPEN (K8/9) and
(K11/12). After all connections, close the gate manually. Turn
off and turn on the power of the control panel in order to
make RESET.
Slow move:
During the Open/Close tests, adjust the SLOW TIME so both
sections go to a fully open or close positions. The position
of the motor torque needs to be at ¼ of the turn.
External button:
1+2 activates both motors while external button 1 activates
ONLY the motor 1.
Photocell 2:
(Κ15) stops the gates’ move immediately for how long the
photocell is activated.
Photocell 1:
(Κ17) works for protection and activates the auto-close.
When the door closes and the photocell beam is cut-off, the
door stops immediately and automatically activates the
open function. If the photocell beam is cut-off, the door
never closes. Auto close: Select dip-switch 4 to activate it.
There is a double counter in the A/C function. The first one
is 120 seconds and is applied when the door stops after an
open function. During this counting time of 120 sec., if the
photocell beam is disturbed, then after the beam is free,
the A/C counting time becomes 10 sec. until the fully closed
position.
Motor delay:
Motor 1 starts first and after 3sec., starts Motor 2
Repeatable close:
Ιs used only in Hydraulic motors and activates instantly the
Slow close routine every 1H.
Clear memory:
The first step is to clear the rolling code memory. Press the
button CODE of the controller and the RED light goes ON
after a while. Keep it pressed until the light goes off. The
memory is now clear.
Adding a new transmitter with the controller
button:
Press the CODE button and the RED light goes on (after a
small delay). Leave it and during the next 3 seconds, press
the desired transmitter channel button until the RED light
blinks and goes OFF. The new transmitter is saved. Follow
the same procedure to program more (up to 20 or 80) new
transmitters.
Adding a new transmitter remotely:
The motor is stopped. Press a working transmitter button
(already in memory) to start the motor working and hold it
pressed until the motor stops. When it stops, leave it and
press the new transmitter button immediately. The new
transmitter is saved. Repeat steps to program more
transmitters remotely. When the memory is full (20 or 80
transmitters) you cannot add more new transmitters.
Reset the automation:
Case of malfunction, please remove the power supply
(230Vac) for 10 seconds, reconnect and recheck.
Compatible
transmitters:
Based on the model you
have, select the
appropriate transmitter.

This manual suits for next models

5

Other Profelmnet Control Panel manuals

Profelmnet 3029 User manual

Profelmnet

Profelmnet 3029 User manual

Profelmnet 3029 User manual

Profelmnet

Profelmnet 3029 User manual

Profelmnet 3033 User manual

Profelmnet

Profelmnet 3033 User manual

Profelmnet 3433 User manual

Profelmnet

Profelmnet 3433 User manual

Profelmnet 3033 User manual

Profelmnet

Profelmnet 3033 User manual

Popular Control Panel manuals by other brands

Beijer Electronics EPC TA100 AM Service maintenance manual

Beijer Electronics

Beijer Electronics EPC TA100 AM Service maintenance manual

Videofied W Panel installation manual

Videofied

Videofied W Panel installation manual

Radomir Bednar 160NB operating instructions

Radomir Bednar

Radomir Bednar 160NB operating instructions

Nordelettronica NE356T instruction manual

Nordelettronica

Nordelettronica NE356T instruction manual

GE ATS4000 Quick programming guide

GE

GE ATS4000 Quick programming guide

HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING user manual

HEIDENHAIN

HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING user manual

Benninca CP.J4 ESA user manual

Benninca

Benninca CP.J4 ESA user manual

Karibu Modern Finnisch Plug'n'Play 52771 Instructions for installation and use

Karibu

Karibu Modern Finnisch Plug'n'Play 52771 Instructions for installation and use

LOVATO ELECTRIC FFLRA400 instruction manual

LOVATO ELECTRIC

LOVATO ELECTRIC FFLRA400 instruction manual

Fire-Lite Alarms MicroScan-2410B quick start guide

Fire-Lite Alarms

Fire-Lite Alarms MicroScan-2410B quick start guide

Bosch Rexroth IndraControl VCP 05 Project planning manual

Bosch

Bosch Rexroth IndraControl VCP 05 Project planning manual

LynTec RPC quick start guide

LynTec

LynTec RPC quick start guide

AV-GAD EasyLoader AV-2004 Installation and operation manual

AV-GAD

AV-GAD EasyLoader AV-2004 Installation and operation manual

Autronica AutroSafe BS-60 Operator's handbook

Autronica

Autronica AutroSafe BS-60 Operator's handbook

Corby System 2000 instructions

Corby

Corby System 2000 instructions

Bosch AMAX panel 2100 Quick installation guide

Bosch

Bosch AMAX panel 2100 Quick installation guide

LST Series BC216 Brochure & specs

LST

LST Series BC216 Brochure & specs

Geberit AquaClean 147.038.SI.1 user manual

Geberit

Geberit AquaClean 147.038.SI.1 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.