Proliphix EPA-20 User manual

Proliphix EPA-20 and EPA-60 Installation Guide
Release 1.0
Part No. 600-01004-000, Rev. 2
April 2008

Beta Draft Confidential
ii Proliphix EPA-20 and EPA-60 Installation Guide, Release 1.0
Part No. 600-01004-000, Rev. 2
Technical
Support
When contacting Proliphix, Inc. for technical assistance, please have the following information available:
Product model and serial number.
Type of heating/cooling system (example: gas, oil, or electric; warm air, hot water, heat pum p,
steam or gravity).
Location and number of wires attached to your Prolip hix thermostat.
For additional assistance, please contact Proliphix, Inc. Technical Support,
9:00 AM to 5:00 PM Eastern Standard Time Monday to Friday:
Web: www.Proliphix.com
Email: [email protected]
Telephone: 1-866-IPLIVING
Fax: 978-692-3378
Warranty
Information
Proliphix, Inc. warrants its products to be free from manufacturing defe cts in mate rials and workmanship
under normal use for a period of 1 year for Professional and Basic Series Thermostats, Thermal Management
Network Thermostats, Ethernet Power Adapters and Thermal Sensors from the date of purchase.
Proliphix shall not be liable to honor the terms of this warranty if the product has been used in any other
application other than that for which it was intended, or if it has been subjected to misuse, accidental damage,
acts of God, modification, or improper installation procedures. Furthermore, this warranty covers only
products which have all original and unaltered markings and labels (serial numbers, model numbers, etc.) of
manufacture. This limited warranty does not cover the repair of cracked, scratched, broken or modified
plastics; other cosmetic damage; or parts that have been altered, defaced or removed; or the scratching,
cracking or breakage of the product.
This warranty is not transferable.
THE FOREGOING WARRANTIES ARE THE SOLE AND EXCLUSIVE WARRANTIES EXPRESS OR
IMPLIED GIVEN BY PROLIPHIX IN CONNECTION WITH THE PRODUCT, AND PROLIP HIX
DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRIN GEMENT OF
THIRD PARTY RIGHTS. PROLIPHIX DOES NOT PROMISE THAT THE PRODUCT IS ERROR-FREE
OR WILL OPERATE WITHOUT INTERRUPTION. PROLIPHIX WILL NOT BE LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR FOR ANY OTHER LOSSES, EXPENSES OR
DAMAGES RELATING TO PRODUCT DEFECTS OR FA ILURES. CUSTOMER'S SOLE REMEDY, AND
PROLIPHIX'S SOLE OBLIGATION, WITH RESPECT TO ANY PRODUCT DEFECTS OR FAILURES
(REGARDLESS OF WHETHER YOUR CLAIM IS ASSERTED IN CONTRACT, TORT, STRICT
LIABILITY OR OTHERWISE) SHALL BE (AT PROLIPHIX'S SOLE OPTION) REPAIR, REPLACEMENT
OR REFUND OF THE PRICE PAID. IN NO EVENT WILL P ROLIPHIX'S LIABILITY WITH RESPECT
TO A PRODU CT, EXCEED THE PRICE PAID FOR SUCH PRODUCT.
This warranty statement supersedes all previous warranties.
This warranty extends to products purchased directly from Proliphix or an authorized Proliphix agent, dealer,
distributor, or reseller.

Proliphix EPA-20 and EPA-60 Installation Guide, Release 1.0 iii
Part No. 600-01004-000, Rev. 2
Material
Return
Procedure
No merchandise may be returned for credit, exchange, or service without prior authorization from Proliphix.
To obtain warranty service for Proliphix products, contact Proliphix Customer Service (1-866-475-4846) and
request a Return Material Authorization (RMA) number.
Products may be returned for credit, exchange, or service with a Proliphix RMA number and with proof of
purchase. Enclose a note explaining the symptoms of the problem , stating the RMA number, and the name,
address and phone number of the company or individual contact.
Authorized returns must be shipped prepaid to Proliphix at:
Proliphix, Inc.
66 Tadmuck Road
Suite #1
Westford, MA 01886
The RMA number must be clearly marked on the outside of the package. Products received without an RMA
number or without shipping prepaid will be subject to refusal by Proliphix. Proliphix reserves the right to
charge a 15% restocking fee plus shipping costs on any products returned without an RMA.
Return shipping charges following repair of items under warranty shall be paid by Proliphix via standard
ground carrier. In the event that repairs are found to be non-warranty, return shipping charges will be paid by
the purchaser.
FCC Model: NT10e/NT20e, NT100e/h, NT120e/h, NT130e/h, NT150e/h, NT160e/h, TM220e/h, and TM250e/h
EPA: EPA-20 and EPA-60
Made in the USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CSA Power: 24 VAC 45mA 60Hz
48VDC 22mA 60Hz
Switched power each contact: 24VAC 2A 60Hz

Beta Draft Confidential
iv Proliphix EPA-20 and EPA-60 Installation Guide, Release 1.0
Part No. 600-01004-000, Rev. 2

Proliphix EPA-20 and EPA-60 Installation Guide, Release 1.0 1
Part No. 600-01004-000, Rev. 2
Beta Draft Confidential
Overview
The Proliphix EPA-20 and EPA-60 Installation Guide describes how to install the
Proliphix Ethernet Power Adapter 20 (EPA-20) and Ethernet Powe r Adapter 60
(EPA-60).
Before you Begin
Before you can install the EPA-20 and EPA-60, you must:
Determine a suitable location for the adapter, preferably near the Network switch
or router.
Verify a CAT5, CAT5E, or CAT6 cable is installed between the adapter and the
Proliphix thermostat.
Installing the EPA-20 and EPA-60
The following tools are required to install the EPA-20 and EPA-60:
#2 Phillips head screwdriver
110 punch down tool, included
Mounting and Wiring the EPA-20 and EPA-60
This section de scribes how to mount and wire the EPA-20 and EPA-60.
1Remove the adapter from packaging.
2Mount the adapter with 1” screws prov ided.
3Strip the end of the CAT5, CAT5E, or CAT6 cable sheathing approximately 1 ½”.
Caution
The EPA-20 and EPA-60 should only be powered with the Proliphix power supply
included with the EPA-20 and EPA-60. Do not power the EPA-20 or EPA-60 with
any other power supply.
Note
You can attach up to two Proliphix thermostats to a single EPA-20 adapter and up
to six Proliphix thermostats to a single EPA-60 adapter.
Note
I
If the adapter is being installed on wallboard then anchors may be necessary.

Beta Draft Confidential
2 Proliphix EPA-20 and EPA-60 Installation Guide, Release 1.0
Part No. 600-01004-000, Rev. 2
Mounting and Wiring the EPA-20 and EPA-60
4Untwist the wire pairs.
5Attach the other end of the CAT5, CAT5E, or CAT6 cable to the Proliphix thermostat.
Refer to Figure 1 to wire the EPA-20.
Refer to Figure 2 to wire the EPA-60.
Figure 1 EPA-20 Wiring
Caution
Do not strip individual wires.
Note
The 110 terminal and RJ-45 ports with the same number are part of the same
connection. The connection is from the thermostat backplate into the EPA then
continues from the RJ-45 to the network (router, switch, etc.).
Caution
You MUST use the T568A wiring scheme on the thermostat backplate when
connecting to the EPA. The EPA 110 block is wired as a T568A terminal, so both
ends of the same wire must use the same scheme.
Note
I
You must verify the appropriate wires are placed in the correct pin holes on the
adapters’s punch down terminal.
Ethernet
Power
Adapter
Model EPA-20
1
2
1
2
24 VDC
white-blue
white-orange
white-green
white-brown
blue
orange
green
brown
24VDC
Power Supply
CAT5
wire to
Proliphix
Device
CAT5 Cable to
Router or
Ethernet switch
110 Punch
down Terminal
CAT5 jack

Beta Draft Confidential Mounting and Wiring the EPA-20 and EPA-60
Proliphix EPA-20 and EPA-60 Installation Guide, Release 1.0 3
Part No. 600-01004-000, Rev. 2
Figure 2 EPA-60 Wiring
6Use a 110 punch down tool and punch each wire to one of the thermostat’s punch
down terminal pins. Refer to Figure 1 and Figure 2.
7Match the adapter ’s CAT5, CAT5E, or CAT6 Jack port(s) to the corresponding punch
down terminal port(s).
8Plug a CAT5, CAT5E, or CAT6 patch cable from the adapter ’s CAT5, CAT5E, or
CAT6 Jack port(s) to a router or Ethernet switch.
Ethernet
Power
Adapter
Model EPA-60
1
2
3
4
5
6
1
2
34
56
24 VDC
white-blue
white-orange
white-green
white-brown
blue
orange
green
brown
24VDC
Power Supply
CAT5
wire to
Proliphix
Device
CAT5 Cable to
Router or
Ethernet switch
110 Punch
down
Terminal
CAT5 jack
Note
The patch cable should be a straight through cable.
Caution
Do not apply power until the Proliphix thermostat is attached to the other end of
the CAT5, CAT5E, or CAT6 cable(s). Plug the 24VDC power supply into the
adapter which supplies power to the Proliphix thermostat attached to the adapter.

Beta Draft Confidential
4 Proliphix EPA-20 and EPA-60 Installation Guide, Release 1.0
Part No. 600-01004-000, Rev. 2
Mounting and Wiring the EPA-20 and EPA-60
This manual suits for next models
1
Table of contents
Other Proliphix Adapter manuals