Pronteau Produo PROBOIL.2 User manual

PROBOIL.2
Produo
2 Way Dispenser Installation Guide
⚠
These instructions should be used in
These instructions should be used in These instructions should be used in
These instructions should be used in conjunction with the principal
conjunction with the principal conjunction with the principal
conjunction with the principal instruction booklet suppl
instruction booklet supplinstruction booklet suppl
instruction booklet supplied
iedied
ied, you should
, you should , you should
, you should
substitute
substitutesubstitute
substitute
the section referring to the installation of the 3in1 tap with this guide
the section referring to the installation of the 3in1 tap with this guidethe section referring to the installation of the 3in1 tap with this guide
the section referring to the installation of the 3in1 tap with this guide
Important Technical Data
Important Technical DataImportant Technical Data
Important Technical Data
Minimum operating pressure (cold): 1 5 bar Maximum operating pressure: 5 5 bar*
Flow characteristics: Dual flow filtered water, Boiled water through centre insulated spout channel
*If these pressures are exceeded, even for short periods, damage can result In these instances a pressure reducing valve should be
installed
This product is manufactured in accordance with recognised European standards Please ensure that your product is fitted in
accordance with Local Water Byelaws
A
AA
A
su
susu
suitable non
itable nonitable non
itable non-
--
-return (check) valve
return (check) valvereturn (check) valve
return (check) valve
should be installed to
should be installed to should be installed to
should be installed to the cold supply
the cold supplythe cold supply
the cold supply
to prevent backflow
to prevent backflowto prevent backflow
to prevent backflow, a
non-return valve on the cold supply before 3 way tee (F1) is required (see instructions key)
These installation guidelines have been prepared for your direction and you must exercise due care at all times We do not accept
responsibility for problems that may occur through improper installation Whilst assembling the tap take care not to accidentally
loosen any factory fixed assemblies
This tap has been 100% assembly tested; therefore you may expect a small residual amount of water to remain in the tap when
delivered Any water marks can be removed using the supplied care advice
Installation Preparation
Installation PreparationInstallation Preparation
Installation Preparation
⚠
Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any
remaining solder, swarf or impurities from your system Failure to carry out this simple procedure could cause problems or damage to
the workings of the dispenser or boiler
We recommend installing particle filters (not shown) and an isolation valve to the cold feed pipe in an accessible position This will
help to prevent premature failure of the valves and ease any future maintenance
Ensure you have suitable domestic cold water pressure before installing this product (see technical data for more information
Ensure you have suitable domestic cold water pressure before installing this product (see technical data for more informationEnsure you have suitable domestic cold water pressure before installing this product (see technical data for more information
Ensure you have suitable domestic cold water pressure before installing this product (see technical data for more information)
))
)
All parts should be removed from their packaging and inspected for any transport damage and that all parts are present prior to
installation
Shut off your water supply system, ensure that your mains stopcock is closed Open the lowest cold tap in the house and allow the
water to run until fully stopped
If replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool, the tap hole area should be free from
dirt and sealant Loosely position the tap and tail pipes to check if any alteration to the existing pipework is required If this is the case
do this now
If replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool,
the tap hole area should be free from dirt and sealant Loosely position the tap and tail pipes to
check if any alteration to the existing pipework is required If this is the case do this now
This dispenser requires a Ø35mm tap hole
This dispenser is designed to be installed in a worktop with a maximum thickness of 50mm

Parts and Contents
Parts and ContentsParts and Contents
Parts and Contents
Key
KeyKey
Key
Description
DescriptionDescription
Description
Qty
QtyQty
Qty
A1 Dispenser body 1
A2 Fixing stud 1
A3 Base plinth 1
A4 Base plinth nut 1
A5 Base plinth seal 1
A6 White triangular plate (for steel
sinks only)
1
A7 Lower gasket 1
A8 Metal horseshoe 1
A9 Fixing nut 1
B1 Cold filtered water to boiler flexible
hose (3/8”) (including seal) 1
B2 3/8” M x ¼”F adaptor 1
B3 ¼” NPT M x ¼” pushfit 1
C1 Cold filtered water inlet 3/8” 1
C2 3/8” M x ¼” F adaptor 1
C3 ¼” NPT M x ¼” pushfit 1
C4 ¼” outside diameter plastic pipe 1*
C5 Filter bracket screw 1
C6 Filter bracket 1
C7 GAC & Resin Filter Cartridge 1
D1 110° rated hot water 3/8” flexi hose
(from boiler output)
1
D2 3/8”fibre seal 1
E1 Boiler 1*
E2 Flexible rubber boiled water output
pipe
1*
E3 Connecting tundish assembly 1*
E4 Flexible drain pipe 1*
F1 ½” (15mm) x ½” (15mm) x ¾” 3 way
isolating tee
1
F2 ¾” BSP x ¼”” push fit 1
F3 15mm Compression olive 2
F4 15mm Compression nut 2
G1 15mm Compression olive 0
G2 15mm compression nut 0
G3 Non-return (check) valve 0
G4 Cold water supply 0
*Part supplied with boiler pack
⚠
Do not switch on the boiler
Do not switch on the boilerDo not switch on the boiler
Do not switch on the boiler
until
until until
until
instructed
instructedinstructed
instructed
PT1120RMCins-v1
02/18

Tap & Filter Installation
Tap & Filter InstallationTap & Filter Installation
Tap & Filter Installation
This diagram shows
the view of the base
of the tap (A1) with
the boiling water
handle to the right of
the body
The flexible hose
The flexible hose The flexible hose
The flexible hose
assembly
assembly assembly
assembly locations
locationslocations
locations
must be respected
must be respectedmust be respected
must be respected
This diagram shows the
markings on boiler (E1)
to indicate the inlet and
outlet See the boiler
instructions for further
detail
boiler hot water outlet
boiler cold water inlet
Install the tap:
Install the tap:Install the tap:
Install the tap:
1 Screw the fixing stud (A2) into the base of tap (A1) as shown on the above diagram
2 Place the base plinth (A3) over the fixing stud (A2) and fix the base plinth securely into place using the base plinth nut (A4)
3 Hand tighten the cold filtered water to boiler flexi hose (B1) into the base of tap (A1) as shown on the above diagram
4 Hand tighten the cold filtered inlet flexi hose (C1) into the base of tap (A1) as shown on the above diagram
5 Hand tighten the 110° ⚠ rated hot flexi hose (D1) into the base of tap (A1) as shown on the above diagram
6 Pass the base plinth seal (A5) over the flexible hoses (B1, C1, D1) and fixing stud (A2) onto the base of the tap (A3)
7 Screw pushfit (C3) into adaptor (C2), we recommend using PTFE tape (do not use sealing compound) on the thread of pushfit
(C3) to make a good seal without applying excessive force (which may damage the plastic pushfit if overtightened)
8 Screw pushfit (C3) and adaptor (C2) into the cold filtered water inlet flexi hose (C1)
9 Screw pushfit (B3) into adaptor (B2), we recommend using PTFE tape (do not use sealing compound) on the thread of pushfit
(B3) to make a good seal without applying excessive force (which may damage the plastic pushfit if overtightened)
10 Screw pushfit (B3) and adaptor (B2) into the cold filtered water to boiler flexi hose (B1)
11 Place the tap (A1-A5) centrally and straight to the tap hole, passing the fixing stud (A2), flexi hoses (B1, C1, D1) through the
tap hole one at a time
12 Pass the lower gasket (A7) then the metal horseshoe (A8) over the fixing stud (A2) Note: only if the tap is to be fitted to a
stainless steel sink then the white triangular plate (A6) can be fitted where shown to improve the stability of the tap and
create more space for the fixing nut (A9)
13 Using an 11mm box spanner or small adjustable spanner tighten fixing nut (A9) onto the fixing stud (A2) fixing the tap
straight and central to the tap hole
14 Measure and then cut required length of ¼” pipe (C4) to connect pushfit (B3) to the boiler (E1) The ¼” pipe (C4) must be cut
cleanly and squarely with a sharp tube snip
15 Connect the 110° ⚠ rated hot flexi hose (D1) to the tundish assembly as instructed later once the boiler is installed

Install the Filter:
Install the Filter:Install the Filter:
Install the Filter:
1 Pass compression nut (F4) then compression olive (F3) over the 15mm cold supply pipe (G4) dependant on if the non-return valve (G3) is
fitted
2 Place the three-way tee (F1) onto the 15mm cold supply pipe (G4) dependant on if the non-return valve (G3) is fitted Note the blue lever
valve on the three-way tee (F1) should face forwards for easy access by the customer
3 Whilst holding three-way tee (F1) tighten compression nut (F4) fixing the three-way tee (F1) to the 15mm pipe (G4)
4 Screw the ¾” BSP x ¼” pushfit (F2) onto the three-way valve (F1) ¾” male output
5 Find a suitable place to mount the filter cartridge (C7) under the sink It must be mounted vertically as shown, easily accessible (to be
changed periodically), away from any heat source and close enough not to exceed the available length of the ¼” plastic pipe (C4) supplied
6 Using the self-tapping screw (C5) securely fix the filter bracket (C6) to the cabinet wall
7 Write the installation date onto the filter label in permanent pen then clip the filter cartridge (C7) into the bracket (C6) as shown You must
respect the direction of flow as indicated
8 Measure and then cut required length of ¼” pipe (C4) to connect pushfit (C3) to the filter cartridge (C7) outlet, then from the filter
cartridge (C7) inlet to the ¾” BSP x ¼”” push fit (F2) leave a little additional length on both pipes to allow the filter cartridge (C7) to be
unclipped and replaced more easily by the customer The ¼” pipe (C4) must be cut cleanly and squarely with a sharp tube snip
After Installation
After InstallationAfter Installation
After Installation:
::
:
1 Please refer to ‘boiler installation and user guide’ for the next steps and complete the installation
Do not plug in the boiler until advised
Do not plug in the boiler until advisedDo not plug in the boiler until advised
Do not plug in the boiler until advised
2 Reconnect the domestic cold water supply then open isolation valves As the system starts to refill, check carefully all new water
connections for leaks After the product installation is complete we recommend you recheck for any slower leaks
3 Turn on the right hand hot water handle fully backwards, keeping the lever open until all air is expelled and cold (unboiled) water exits the
centre channel of the tap spout, flush a further 10 litres of cold (unboiled) water through the filter, boiler and tap You may notice a
discolouration to the water at first This is loose carbon fines from the filter It is normal, harmless and will pass with flushing Once
complete turn off the right hand hot water handle
4 Plug in and switch on the boiler, then wait until the water has finished heating fully
5 Clean the tap with a damp soft cloth and a mild detergent to remove any grease marks created during installation as per the care
instructions
⚠
Do not add to, exchange or modify any component of the boiler or tap, only genuine parts must be used The spout exit or any part of the system
must not include any additional third party adaptors, components or connections that will add resistance or modify the system
⚠
The installation should be periodically checked for damage If the property is left unattended for a prolonged period we recommend isolating water
supplies and switching off the boiler at the mains socket On reconnection flush thoroughly
Using the Product:
Using the Product:Using the Product:
Using the Product:
Hot (boiled & filtered) water
Hot (boiled & filtered) water Hot (boiled & filtered) water
Hot (boiled & filtered) water –
––
–
Fully push the right hand lever
down (Fig 1 ) and then simultaneously turn the handle
backwards (Fig 2 ), the further backwards the lever is turned
the greater the flow At around 45° rotation is reached (Fig 2 )
the maximum flow is achieved It is normal for the hot water
to take a moment to dispense as the water empties from the
product after use
Cold filtered water
Cold filtered water Cold filtered water
Cold filtered water –
––
–
Turn the handle forwards for the cold
filtered water (Fig 3 ), the further forwards the lever is turned
the greater the flow At around 45° rotation is reached (Fig 3 )
the maximum flow is achieved
⚠
Should you see that hot water persistently drips from the
centre channel of the tap spout (when the tap is not in use and
the boiler indicator red light is switched on) then you should
reduce the temperature adjustment dial on the top of the
boiler See the calibration procedure for further information
Each time the product is used you should flush a small
amount of boiled water through before use Typically this can
be used to preheat your cup If unused for extended periods
then flush the product for a longer time
Other manuals for Produo PROBOIL.2
3
Table of contents