ProtACT PR Series User manual

MANUAL- AND
MAINTENANCE GUIDELINES
Dokumentnr.: BWA.PR.201001| Issued: 03/2023
PR Series
PNEUMATIC ACTUATORS

2
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
Notes

3
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
Contents:
Chapter 1: Preparaon
1.1 Marking of reference............................................................... Page 4
1.2 Safety fundamentals................................................................ Page 4
1.3 Transport, storage and packaging............................................ Page 4
Chapter 2: Preliminary
.............................................................................. Page 5
2.2 Intended use............................................................................ Page 5
2.3 Technical data.......................................................................... Page 6
2.4 Air volumes.............................................................................. Page 6
...................................................................... Page 7
2.6 Type code ................................................................................ Page 8
Chapter 3: Funcon
3.1 Fundamentals - valve closing clockwise .................................. Page 9
.......................... Page 9
.................. Page 13
............ Page 13
Chapter 4: Installaon
.............................................................. Page 16
............................................................. Page 17
4.3 End stop adjustment ............................................................... Page 18
4.4 Stroke adjustment ................................................................... Page 19
Kapitel 5: Maintenance
5.1 General .................................................................................... Page 20
................................................................... Page 20
.............................. Page 20
5.4 Components ............................................................................ Page 21
........................................................ Page 22
5.6 Disassembly............................................................................. Page 22
5.7 Reassembly.............................................................................. Page 24
5.8 Arrangement of safety springs ................................................ Page 26
Copyright

4
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
Chapter 1: Preparaon
Content:
»
»Safety fundamentals
»
1.1 Marking of safety instrucons
This symbol indicates safety instrucons which can cause personal injury if not respected.
This symbol indicates an important note.
1.2 Safety fundamentals
Rotary actuators must be isolated both pneumacally and electrically before any intervenonwerden.
Failure to follow the safety basics can void the warranty claims
Installaon, operaon and maintenance of the products are strictly subject to the local safety and
accident prevenon regulaons!
1.3 Transport, storage and packaging
The devices must be carefully handled, transported and stored.
temperature changes.
Proper disposal of packaging is the customer´s responsibility.
Failure to comply may void the warranty claims.

5
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
Chapter 2: Preliminary
Content:
»
»Intended use
»
»Type code
2.1 Design descripon
provided to the central actuator pinion via toothed racks which are connected with the pistons and so creates a
2.2 Intended use
use of choke valves, which can be purchased through our sales department.
coordinated with us in advance.
The actuator may only be used:
»
»
»
»
In parcular faults which may aect safety are to be eliminated!
Any use not pre-approved by the manufacturer is considered improper!

6
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
2.3 Technical data
Construcon principle
Materials
Temperature range
Standard -20°C...+80°C
Low temperature variant -40°C...+80°C
-10°C...+150°C
Control pressure 2,5...8 bar
Pressure media
dew point minimum 10°C below ambient temperature
Mounng direcon Any
Nominal rotaon angle
90° resp. 180°
Torque range
Standards
Interface
Interface
Interface
Actuator size
002 003 004 007 010 015 023 033 052
Volume (l)
double-acng 0,09 0,19 0,28 0,44 0,64 0,90 1,37 1,83 3,0
single-acng - - 0,12 0,21 0,30 0,43 0,64 0,95 1,6
088 134 216 263 387 587 763 1143 1628
Volume (l)
double-acng 4,7 6,9 11,3 15,0 20,0 31,0 53,5 81,4 108,6
single-acng 2,5 3,7 5,9 7,5 11,0 17,0 23,8 35,1 52,6
2.4 Air volumes

7
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
2.5 Luverbrauch
Air consumpon for pivong angle 90° at control pressure in bar (g) in litres/cycle
Size Funcon 33,5 44,5 55,5 678
002
double-acng 0,27 0,32 0,36 0,41 0,45 0,50 0,54 0,63 0,72
single-acng - --------
003
double-acng 0,57 0,67 0,76 0,86 0,95 1,05 1,14 1,33 1,52
single-acng - --------
004
double-acng 0,84 0,98 1,12 1,26 1,40 1,54 1,68 1,96 2,24
single-acng 0,36 0,42 0,48 0,54 0,60 0,66 0,72 0,84 0,96
007
double-acng 1,32 1,54 1,76 1,98 2,20 2,42 2,64 3,08 3,52
single-acng 0,63 0,74 0,84 0,95 1,05 1,16 1,26 1,47 1,68
010
double-acng 1,92 2,24 2,56 2,88 3,20 3,52 3,84 4,48 5,12
single-acng 0,90 1,05 1,20 1,35 1,50 1,65 1,80 2,10 2,40
015
double-acng 2,70 3,15 3,60 4,05 4,50 4,95 5,40 6,30 7,20
single-acng 1,29 1,51 1,72 1,94 2,15 2,37 2,58 3,01 3,44
023
double-acng 4,11 4,80 5,48 6,17 6,85 7,54 8,22 9,59 10,96
single-acng 1,92 2,24 2,56 2,88 3,20 3,52 3,84 4,48 5,12
033
double-acng 5,49 6,41 7,32 8,24 9,15 10,07 10,98 12,81 14,64
single-acng 2,85 3,33 3,80 4,28 4,75 5,23 5,70 6,65 7,60
052
double-acng 9,00 10,50 12,00 13,50 15,00 16,50 18,00 21,00 24,00
single-acng 4,80 5,60 6,40 7,20 8,00 8,80 9,60 11,20 12,80
088
double-acng 14,10 16,45 18,80 21,15 23,50 25,85 28,20 32,90 37,60
single-acng 7,50 8,75 10,00 11,25 12,50 13,75 15,00 17,50 20,00
134
double-acng 20,7 24,2 27,6 31,1 34,5 38,0 41,4 48,3 55,2
single-acng 11,1 13,0 14,8 16,7 18,5 20,4 22,2 25,9 29,6
216
double-acng 33,9 39,6 45,2 50,9 56,5 62,2 67,8 79,1 90,4
single-acng 17,7 20,7 23,6 26,6 29,5 32,5 35,4 41,3 47,2
263
double-acng 45,0 52,5 60,0 67,5 75,0 82,5 90,0 105,0 120,0
single-acng 22,5 26,3 30,0 33,8 37,5 41,3 45,0 52,5 60,0
387
double-acng 60,0 70,0 80,0 90,0 100,0 110,0 120,0 140,0 160,0
single-acng 33,0 38,5 44,0 49,5 55,0 60,5 66,0 77,0 88,0
587
double-acng 93,0 108,5 124,0 139,5 155,0 170,5 186,0 217,0 248,0
single-acng 51,0 59,5 68,0 76,5 85,0 93,5 102,0 119,0 136,0
763
double-acng 160,5 187,3 214,0 240,8 267,5 294,3 321,0 374,5 428,0
single-acng 71,4 83,3 95,2 107,1 119,0 130,9 142,8 166,6 190,4
1143
double-acng 244,2 284,9 325,6 366,3 407,0 447,7 488,4 569,8 651,2
single-acng 105,3 122,9 140,4 158,0 175,5 193,1 210,6 245,7 280,8
1628
double-acng 325,8 380,1 434,4 488,7 543,0 597,3 651,6 760,2 868,8
single-acng 157,8 184,1 210,4 236,7 263,0 289,3 315,6 368,2 420,8
2.5 Air consumpon

8
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
2.6 Typecode
PR 004 S.10 .090 .0305 S11 .PRS
Type
Temperature version
S:
H:
D: T:
S: Spring rotaon sense
Spring set
R: Clockwise CW
Rotaon angle
L: Counterclockwise CCW
Mounng direcon
ISO valve interface P: Parallel to pipe
03: F03 0305: F03 + F05 T: Transversal to pipe
04: F04 0507: F05 + F07 Stem connecon dimension
05 0710: F07 + F10 Dimension in mm
07: F07 1012: F10 + F12 Stem connecon
10: F10 1625: F16 + F25 S:
12: F12
14: F14 D: Double-D
16: F16
25: F25

9
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
Kapitel 3: Funkon
Inhalte:
»Fundamentals
»
»
»
3.1 Fundamentals
3.2 are based on this rule and have to be taken into account accordingly.
Closing process clockwise (CW)
Opening process counter-clockwise (CCW)
3.2 Mounng versions – valve closing clockwise

10
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
Mounng version PR
Actuator parallel to pipeline
Spring rotaon sense clockwise (CW)
SPRING TO CLOSE
Double-acng
Valve posion
Single-acng
Port "A" vented, actuator moves in
Mounng version PL
Actuator parallel to pipeline
Spring rotaon sense counter-clockwise (CCW)
SPRING TO OPEN
Double-acng
Valve posion
Single-acng
Port "A" vented, actuator moves in

11
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
Mounng version TR
Actuator transversal to pipeline
Spring rotaon sense clockwise (CW)
SPRING TO CLOSE
Double-acng
Valve posion
Single-acng
Port "AB" vented, actuator moves in
Mounng version TL
Actuator transversal to pipeline
Spring rotaon sense counter-clockwise (CCW)
SPRING TO OPEN
Double-acng
Valve posion
Single-acng
Port "A" vented, actuator moves in

12
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023

13
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
3.3 Exceponal case: valve closing counter-clockwise
Closing process counter-clockwise (CCW)
Closing process counter-clockwise (CCW)
3.4 Mounng versions – valve closing counter-clockwise

14
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
Mounng version PR
Actuator transversal to pipeline
Spring rotaon sense clockwise (CW)
SPRING TO OPEN
Double-acng
Valve posion
Single-acng
Port "A" vented, actuator moves in
Mounng version PL
Actuator transversal to pipeline
Spring rotaon sense counter-clockwise (CCW)
SPRING TO CLOSE
Double-acng
Valve posion
Single-acng
Port "A" vented, actuator moves in
!!! EXCEPTIONAL CASE – VALVE CLOSING COUNTER-CLOCKWISE !!!

15
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
Mounng version TR
Actuator parallel to pipeline
Spring rotaon sense clockwise (CW)
SPRING TO OPEN
Double-acng
Valve posion
Single-acng
Port "AB" vented, actuator moves in
Mounng version TL
Actuator parallel to pipeline
Spring rotaon sense counter-clockwise (CCW)
SPRING TO CLOSE
Double-acng
Valve posion
Single-acng
Port "A" vented, actuator moves in
!!! EXCEPTIONAL CASE – VALVE CLOSING COUNTER-CLOCKWISE !!!

16
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
4. Installaon
Content:
»
»
»End stop and stroke adjustment
4.1 Aachment to a valve
Perform any kind of installaon work on rotary actuators exclusively when the device is fully vented!
Verify that the maximum actuator torque is below the maximum valve torque (MAST) to avoid further
damage.
•
•
•
inserts. These can be ordered via our sales department separately.
•
is required, which can be ordered via our sales department.
• Secure the drive with screws on the valve. We recommend using stainless steel screws to ensure a

17
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
4.2 Pneumac connecon
mounted control valve that silencer is to be removed.
Pneumac controls
Double-acng Single-acng
Control via 5/2-way valve
Sample safety funcon:
power-o in inial posion
Control via 3/2-way valve

18
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
4.3 End stop adjustment
Perform any kind of adjustment on rotary actuators exclusively when the device is fully vented!
Disconnect the compressed air supply before any seng.
Adjustment of the inial posion:
1.
single-acng
double-acng
2.
•
•
3.
Adjustment of the switched posion:
1.
2.
3.
4.
The adjusng screws may only be unscrewed so far that the screw ends protrude a few millimeters
beyond the locknuts and may only be screwed in so far that the adjusng screws sll remain fully in
the thread of the locknuts.

19
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
4.4 Stroke adjustment
Perform any kind of adjustment on rotary actuators exclusively when the device is fully vented!
Disconnect the compressed air supply before any seng.
4. Secure the drive pinion using a wrench on the pinion square, turn
The adjustment screws may be turned in only so far that the adjustment screws fully remain in the
lock nut threads.
9
0°
+5°
-20°
Stroke adjustment (Standard)
100%
Stroke adjustment (Optional)

20
Manual and maintenance Guidelines
Pneumac actuator PR Series
BWA.PR.150201
March 2023
5. Maintenance
Content:
»General
»
»
»Actuator components and spare parts
»
»
5.1 General
Regular replacement of the seals and bearings in the actuator extend the normal span of duty. Appropriate spare
parts kit can be ordered via our sales department.
5.2 Safety instrucons
Rotary actuators must be isolated both pneumacally and electrically before any work is
performed.
Actuators and the connected valve can move when the control pressure and/or an electrical control
signal is removed.
Single acng actuators with incomplete spring stroke contain a high spring force that can trigger
a sudden rotaon during dismounng of the actuator. This can cause serious injuries or property
damage.
Work on electrical installaons must be carried out exclusively by suitably qualied persons. A
disabled supply must be protected against accidental reconnecon.
5.3 Tightening torques for screw connecons
Tightening torques in Nm
Nominal size min. max.
M5 4,9 6
M6 8 10
M8 20 25
M10 40 49
M12 69 86
M16 170 210
M18 235 290
M20 330 410
Table of contents
Other ProtACT Controllers manuals
Popular Controllers manuals by other brands

Di-soric
Di-soric IO-Link Device Tool V 4.0 instruction manual

ComAp
ComAp InteliNano NT Plus user guide

Freescale Semiconductor
Freescale Semiconductor MC33794 Setup instructions

Sun Yeh Electrical
Sun Yeh Electrical S Series Operation manual

Linkam Scientific Instruments
Linkam Scientific Instruments LTSE420-P user guide

Epson
Epson RC620 Series Mounting procedure

Kelly
Kelly KLS-S user manual

Exlar
Exlar Curtiss-Wright Tritex TTX Series Installation & service instructions

VAC
VAC V200P Installation, operation and maintenance instructions

Eliwell
Eliwell ID 985 manual

Clarke
Clarke weld IR1A Operating & maintenance instructions

Providence
Providence PEC-4V owner's manual