manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Pulsar
  6. •
  7. Power Supply
  8. •
  9. Pulsar PSB-24V2A User manual

Pulsar PSB-24V2A User manual

Other Pulsar Power Supply manuals

Pulsar HPSBOC 5048C User manual

Pulsar

Pulsar HPSBOC 5048C User manual

Pulsar PSD480250 User manual

Pulsar

Pulsar PSD480250 User manual

Pulsar PSBBH 1012 User manual

Pulsar

Pulsar PSBBH 1012 User manual

Pulsar AWZ 110 User manual

Pulsar

Pulsar AWZ 110 User manual

Pulsar PSBEN 1012B User manual

Pulsar

Pulsar PSBEN 1012B User manual

Pulsar AWO 466 User manual

Pulsar

Pulsar AWO 466 User manual

Pulsar PSBEN 2024C User manual

Pulsar

Pulsar PSBEN 2024C User manual

Pulsar PSCL12070 User manual

Pulsar

Pulsar PSCL12070 User manual

Pulsar ADOC551230 User manual

Pulsar

Pulsar ADOC551230 User manual

Pulsar AWZ 222 User manual

Pulsar

Pulsar AWZ 222 User manual

Pulsar Black Power PSBEN 1024B/LCD User manual

Pulsar

Pulsar Black Power PSBEN 1024B/LCD User manual

Pulsar PSC12010 User manual

Pulsar

Pulsar PSC12010 User manual

Pulsar GREEN POWER CCTV POE084824B User manual

Pulsar

Pulsar GREEN POWER CCTV POE084824B User manual

Pulsar PSCL12050 User manual

Pulsar

Pulsar PSCL12050 User manual

Pulsar DING2 Series User manual

Pulsar

Pulsar DING2 Series User manual

Pulsar BLACK POWER PSBEN 10A12C User manual

Pulsar

Pulsar BLACK POWER PSBEN 10A12C User manual

Pulsar PSDC 161214 User manual

Pulsar

Pulsar PSDC 161214 User manual

Pulsar EN54-5A40LCD User manual

Pulsar

Pulsar EN54-5A40LCD User manual

Pulsar PSBEN 5012C/LCD User manual

Pulsar

Pulsar PSBEN 5012C/LCD User manual

Pulsar PSBOC1552455 User manual

Pulsar

Pulsar PSBOC1552455 User manual

Pulsar PSP24006 User manual

Pulsar

Pulsar PSP24006 User manual

Pulsar HPSB 10A24C User manual

Pulsar

Pulsar HPSB 10A24C User manual

Pulsar SWS-150 User manual

Pulsar

Pulsar SWS-150 User manual

Pulsar PSC07510 User manual

Pulsar

Pulsar PSC07510 User manual

Popular Power Supply manuals by other brands

Videx 520MR Installation instruction

Videx

Videx 520MR Installation instruction

Poppstar 1008821 Instructions for use

Poppstar

Poppstar 1008821 Instructions for use

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda 500A instruction manual

TDK-Lambda

TDK-Lambda 500A instruction manual

Calira EVS 17/07-DS/IU operating instructions

Calira

Calira EVS 17/07-DS/IU operating instructions

Monacor PS-12CCD instruction manual

Monacor

Monacor PS-12CCD instruction manual

VOLTIMA MagicBox 15 Installation and operating instructions

VOLTIMA

VOLTIMA MagicBox 15 Installation and operating instructions

Miller Auto Deltaweld 452 owner's manual

Miller

Miller Auto Deltaweld 452 owner's manual

BCP PUOUBK How to install

BCP

BCP PUOUBK How to install

HC 2210 manual

HC

HC 2210 manual

Agilent Technologies 6032A Service manual

Agilent Technologies

Agilent Technologies 6032A Service manual

Radial Engineering SB-48UB user guide

Radial Engineering

Radial Engineering SB-48UB user guide

Puls CT5.241 installation manual

Puls

Puls CT5.241 installation manual

OCZ ZX1250W Technical specifications

OCZ

OCZ ZX1250W Technical specifications

iseg ECH 238 manual

iseg

iseg ECH 238 manual

Agilent Technologies 6631B Service manual

Agilent Technologies

Agilent Technologies 6631B Service manual

Power XXL A Series instruction manual

Power

Power XXL A Series instruction manual

HP 6200B Operating and service manual

HP

HP 6200B Operating and service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
PSB-24V2A
PSB 27,6V/2A enclosed switch
mode buffer power supply
Edition: 1 from 28.04.2020
Supercedes the edition: ------------
EN
Features of the power supply:
DC 27,6 V/2 A uninterruptible power supply
high efficiency 90%
controlling of battery charging and maintaining
protecting of battery against excessive discharging
(UVP)
battery charging current 0,2 A/0,5 A, changed by
jumper
optional equipment: set of external LED indicators:
PKAZ168, mounting plate DIN2
battery output is full protected against short-
circuit and reverse connection
LED optical signalisation
protections:
short-circuit protection SCP
over voltage protection OVP
surge protection
overload protection OLP
warranty –2 years from production date
1. Technical description.
1.1.General description.
Buffer-type power supply units are intended for continuous power supply to devices that require stabilised voltage
of 24 V DC (+/-15%). The power supply provides a voltage of U=27,6 V DC with an output current of:
1. Output current of 2 A + 0,2 A battery charging
2. Output current of 1,7 A + 0,5 A battery charging
Total device current + battery: 2,2 A max.
In case of power voltage decay, prompt switching to battery supply occurs. The power supply unit is protected
against a short circuit, an overload, a surge or over voltage protection.
1.2.Technical parameters.
Supply voltage
~ 200 –240 V; 0,8 A; 50/60 Hz
Inrush current
40 A
Supply power
61 W
Efficiency
90%
Output voltage (factory settings)
22-27,6 V DC –buffer operation
19-27,6 V DC –battery operation
Output current
2,2 A
Battery charging current
0,2 A / 0,5 A jumper selectable
Voltage adjustment range
27 –28,8 V DC
Current consumption by PSU during battery-
assisted operation
approx. 10 mA
Ripple voltage
100mV p-p max.
Short-circuit protection SCP
electronic, automatic recovery
Overload protection OLP
105-150% PSU power, automatically recovered
Overload protection (battery) OLP
melting fuse F3 A
Surge protection
varistors
Overvoltage protection OVP
>37 V (activation requires disconnecting the load or supply
for about approx. 1 min)
Excessive discharge protection UVP
U<19 V (± 5%) –disconnection of battery
Optical signalisation
LED green –indicates DC voltage at the power
LED optical indication output (intended for optional
indication set PKAZ168)
LED AC –presence of AC voltage
LED DC –presence of DC voltage on power supply output
LED CHARGE –battery charging process
Optional equipment
A set for optical indication LED PKAZ168
Operation conditions
Temperature: -10oC ÷ +40oC relative humidity 20%...90%,
2
without condensation
Dimensions
L=129, W= 98, H=40 [±2mm]
Net/gross weight
0,31 / 0,35 [kg]
Protection class electric shock protection
I (first) - requires a protective conductor
Connectors
I/O PCB: 0,5 –2,5 mm2(AWG 26 –12)
output of optical signalization: 4 pins micromatch socket
Additional accessories
Battery wires 6,3F –45cm, ML062 angle muff (hole
5,2mm)
Electrical strength of insulation:
- between input (network) circuit and output circuits
of power-supply
- between input circuit and protection circuit
- between output circuit and protection circuit
2500 V AC min.
1500 V AC min.
500 V AC min.
Insulation resistance:
- between input circuit and output or protection
circuit
100 MΩ, 500 V DC
Storage temperature
-20ºC...+60ºC
Vibrations and impulse waves during transport
according to PN-83/T-42106
1.3. Description of terminals.
Elements/connectors [Fig.1]
Description
[1]
LED for DC output voltage
[2]
Potentiometer - output voltage adjust
[3]
Connector of optical signalization LED
[4]
Power supply output (V+, V-)
[5]
Battery connector (B+, B-)
[6]
Jumper -battery charging current configuration:
Ibat =0,2 A
Ibat =0,5 A
Legend: jumper installed, jumper removed
[7]
L-N –input voltage connectors 230 V,
–protective conductor connector
1.4.Dimensions and fitting of the PSB-24V2A power supply.
3
2. Installation.
2.1. Requirements.
PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a
given country) for low-voltage installations. The device shall be mounted in closed rooms of the normal air humidity
(RH=90% max. without condensation) and the temperature within the range from -10°C to +40°C.
The power supply shall be mounted in a close casing (a cubicle, a terminal device) and in order to fulfill LVD and
EMC requirements the rules for power-supply, encasing and shielding shall be observed according to application.
Due to the power supply design, the protection wire has to be connected to the corresponding connector of the
supply unit. Before installation, prepare a PSU load balance with point 1.1.
2.2. Installation procedure.
Before installation, make sure that the voltage in the 230 V power-supply circuit is cut off. To switch off
power use an external switch in which the distance between the contacts of all poles in the
disconnection state is not less than 3mm.
1. Mount the PSU in a selected location and connect the wires.
2. Connect the power cables (~230 V) to L-N clips of the PSU.
The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire
coat of the power cable shall stick to one side of the ‘ ’ terminal - in the PSU enclosure. Operation of
the PSU without a properly made and fully operational shock protection circuit is UNACCEPTABLE!
It can cause a device failure or an electric shock.
3. Connect the ground wire to the clip marked by the earth symbol (connector of power supply module). Use a three-
core cable (with a yellow and green protection wire) to make the connection. Lead the cables to the appropriate clips of
the subplate through the insulating bushing.
4. Check the PSU output voltage, if needed correct the setting it should by the potentiometer.
5. Connect load / loads to proper output connectors of the power supply (positive end is marked as +V, negative
end as V-)
6. Screw the battery cables to the BAT connector (black B-, red B +).
7. Connect the battery in series paying attention to polarity.
8. Connect the PKAZ168 external optical signalling (optional equipment)
9. Once the tests and control operation have been completed, close the enclosure/cabinet.
3. Maintenance.
All maintenance procedures can be performed after the disconnection of the power supply from the electrical
grid. The power supply does not require any special maintenance procedures, but in the case of significant dust
accumulation, dusting using compressed air is recommended.
Pulsar sp. j.
Siedlec 150, 32-744 Łapczyca, Polska
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: [email protected], [email protected]
http:// www.pulsar.pl, www.zasilacze.pl
WEEE MARKING
According to the EU WEE Directive –It is required not to dispose of electric or electronic waste as unsorted municipal waste and to collect such
WEEE separately.