Table 5. Mechanical parameters
W=525, H=540, D+D1=72+14 [+/- 2mm]
W1=530, H1=545 [+/- 2mm]
The dimensions of the battery
compartment
Steel plate, DC01 1,0mm color white RAL 9003
Cheese head screw x 2 (at the front)
Power supply of the cameras: RJ45 socket
Battery output BAT: 6,3F-2,5
TAMPER output: wires
Table 6. Operation safety
Protection class PN-EN 609501:2007
Protection grade PN-EN 60529: 2002 (U)
Electrical strength of insulation:
- between input and output circuits of the PSU
- between input circuit and PE protection circuit
- between output circuit and PE protection circuit
3000 V AC min.
1500 V AC min.
500 V AC min.
Insulation resistance:
- between input circuit and output or protection circuit
CE, 2 year from the production date
Table 7. Operating parameters
20%...90%, without condensation
Vibrations during operation
Impulse waves during operation
Vibrations and impulse waves during transport
According to PN-83/T-42106
2. Installation.
2.1. Requirements.
The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal
relative humidity (RH=90% maximum, without condensation) and temperature from -10°C to +40°C. Ensure the free flow
of air around the unit. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through
ventilating holes of the enclosure. It is required to install an installation switch with a nominal current of min. 3 A in the
power supply circuits outside the power supply unit.
The switch load balance should be done before installation. The given value of 30 W per port is the maximum value
referring to a single output. The total power consumption should not exceed 192 W. The increased demand for power is
particularly evident in the case of cameras with heaters or infrared illuminators - when launching these features, the
power consumption increases rapidly, which may adversely affect the operation of the switch. As the device is designed for
a continuous operation and is not equipped with a power-switch, therefore an appropriate overload protection in the power
supply circuit should be provided. The electrical system shall be made in accordance with applicable standards and regulations.
2.2. Installation procedure
Before installation, cut off the voltage in the 230 V power-supply circuit.
To switch power off, use an external switch, in which the distance between the contacts of all
poles in the disconnection state is not less than 3mm.
2. Mount the PSU in a selected location and connect the wires.
3. Connect the power cables (230 V) to L-N clips of the PSU.