Pulsar SG108-CRB User manual

1
SG108-CRB
v1.0
SG108-CRB 10-ports switch with buffer power supply
for 8 IP cameras and recorder in recorder space
PL
Edition: 2 from 02.07.2018
Supercedes the edition: 1 from 16.04.2018 EN**
Features:
Uninterruptible power supply of 8 IP cameras (52VDC)
Uninterruptible power supply of the recorder (12VDC)
10 ports 10/100/1000Mb/s
8 PoE ports 10/100/1000Mb/s, (data and power supply)
2 ports 10/100/1000Mb/s (UpLink)
30W for each PoE port, supports devices complaint
with the IEEE802,3af/at (PoE+) standard
Supports auto-learning and auto-aging of MAC
addresses (8K size)
Approximate backup time: 3h 15min
LED indication
Metal enclosure –color white RAL 9003
with space for two 17Ah/12V battery and offers
the possibility of recorder installation
The enclosure construction is compliant with
the requirements of the General Data
Protection Regulation GDPR (the possibility
of installing two locks with different codes)
Space for a recorder with the following
dimensions 380x320x65 (WxHxD)
warranty –2 year from the production date
Example of use.
CONTENTS
1. Technical description.
1.1 General description
1.2 Block diagram
1.3 Description of components and connectors
1.4 Technical parameters
2. Installation.
2.1 Requirements
2.2 Installation procedure
3. Indication of the device operation
3.1 LED indication of operating status
3.2 Optical indication of the switch operation
4. Operation and use.
4.1 Overload or short circuit of the PSU output (SCP on)
4.2 Disconnection of discharged battery
4.3 Maintenance

2
1. Technical description
1.1. General description.
The SG108-CRB is dedicated for uninterruptible power supply of 8 IP cameras (52VDC power supply) and
uninterruptible power supply of the DVR (12VDC power supply). In addition, the large size of the enclosure allows installing
the recorder inside. The enclosure construction is compliant with the requirements of the General Data Protection
Regulation GDPR (the possibility of installing two locks with different codes).
The main elements of this system include:
- 10 ports PoE switch
- buffer power supply unit 27,6V which can accommodate two 17Ah / 12V batteries
- a converter (DC/DC52230) increasing the voltage to 52VDC (supply of the PoE switch)
- step down (DC/DC50SD) converter with adjustable output voltage to 12VDC (DVR power supply)
In case of power decay, a battery back-up is activated immediately.
The approximate backup time is given assuming that all output ports are used (using typical devices and 17Ah
batteries). The electricity consumption for own needs and the energy efficiency of the power intake track were taken into
account. The exact description of how to perform the calculations can be found at: "Approximate backup time - assumptions for
calculations".
Automatic detection of any devices powered in the PoE/PoE+ standard is enabled at the 1 - 8 ports of the switch.
The Up Link ports is used for connection of another network device e.g. recorder. The LEDs at the front panel indicate the
operation status (described in the table below).
The switch is housed in a metal enclosure (color RAL 9003) which can accommodate a two 17Ah/12V batteries. The
enclosure features a micro switch tamper indicating door opening (front panel). The SG108-CRB is fitted with two LEDs on the
front panel (red LED –indicates 230VAC power supply of the PSU, green LED indicates the presence of DC voltage).
The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a
separate power cable for each device. This method allows supplying other network devices, such as IP phone, wireless
access point or router.
1.2 Block diagram.
Fig. 1. Block diagram.

3
1.3 Description of components and connectors.
Fig. 2. The enclosure view.
Table 1. (See Fig. 2)
Component No.
(Fig. 2)
Description
[1]
Switch PoE
[2]
Switch mode buffer power supply unit
[3]
DC/DC52230 converter
[4]
DC/DC50SD converter
[5]
Output filter
[6]
Tamper –micro switch (terminals) of tamper protection (NC)
[7]
Battery space for two (2 x 17Ah/12V –connect the batteries in series)
[8]
Space for a recorder 380x320x65 (WxHxD)
[9]
Power supply connector of the PSU –L, N
PE protective connector (electric shock)
[10]
BAT +, BAT - battery output + BAT red, - BAT black
[11]
DVR power cord terminated with the DC 2,1/5,5 plug

4
Fig. 3. The view of the switch.
Table 2. (See Fig.3)
Component No
(Fig. 3)
Description
[1]
8 x PoE ports (1÷8)
[2]
2 x UPLINK port
[3]
52V DC power supply socket
1.4 Technical parameters
- parameters of the switch (tab.3)
- electrical parameters (tab.4)
- mechanical parameters (tab.5)
- operation safety (tab.6)
- operating parameters (tab.7)
Table 3. Parameters of the switch
Ports
10 ports 10/100/1000 Mb/s (8 x PoE + 2 x UpLink)
with connection speed auto-negotiation and MDI/MDIX Auto Cross)
PoE power supply
IEEE 802.3af/at (1÷8 ports), 52V DC / 30W at each port *
Used pairs 4/5 (+), 7/8 (-)
Protocols, Standards
IEEE802.3, 802.3u, 802.3x CSMA/CD, TCP/IP
Bandwidth
16Gbps
Transmission method
Store-and-Forward
Optical indication of
operation
Switch power supply;
Link/Act;
PoE Status
*The given value of 30W per port is the maximum value. The total power consumption should not exceed 120W when all PoE ports are being used.
Table 4. Electrical parameters
Mains supply
AC 176÷264V/50Hz
Current up to
1,3A/230V AC max.
Supply power
208W
Output current at the PoE ports (RJ45)
8 x 0,6A ΣI=2,3A (max.)
Output voltage at the PoE ports (RJ45)
52VDC
Output current (recorder)
5A
Output voltage (recorder)
12VDC
Short-circuit protection SCP and overload protection OLP
105% ÷ 150% of power supply, manual restart
(the fault requires disconnection of the DC output circuit)
PSU current consumption
300mA / 27,6V
Battery charge current
1A max. / 2x17Ah (+/-5%)
Approximate backup time
3h 15min
Battery circuit protection SCP and reverse
polarity connection
melting fuse

5
Deep discharge battery protection UVP
U<19V (± 5%) – disconnection of the batteries
Sabotage protection:
- TAMPER output indicating enclosure opening
- microswitch, NC contacts (enclosure closed),
0,5A@50V DC (max.)
Table 5. Mechanical parameters
Dimensions
W=421, H=535, D+D1=193+14 [+/- 2mm]
W1=426, H1=540 [+/- 2mm]
Dimensions of recorder
space
W2=380, H2=320, D2=65 [+/- 2mm]
The dimensions of the
battery compartment
370x180x80 (WxHxD)
Gross/Net weight
10,8 / 11,6 kg
Enclosure
Steel plate, DC01 1,0mm color white RAL 9003
Closing
Cheese head screw x 2 (at the front)
The possibility of installing two locks with different codes.
Connectors
Power supply of the cameras: RJ45 socket
Power supply for recorder: DC2,1/5,5 plug
230V AC input: Φ0,63-2,50 (AWG 22-10),
Battery output BAT: 6,3F-2,5
TAMPER output: wires
Notes
The enclosure does not touch the assembly surface so that cables can be led.
Table 6. Operation safety
Protection class PN-EN 609501:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V/DC
Declarations
CE
Table 7. Operating parameters
Operating temperature
-10ºC...+40ºC
Storage temperature
-20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106
2. Installation
2.1. Requirements
The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and
required for a given country) for 230V/AC and low-voltage installations.
The device shall be mounted in confined spaces, according to the environment class II, with normal air humidity
(RH=90% max. without condensation) and the temperature from -10°C to +40°C.
The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of
the enclosure.
Before installation, prepare a Switch'a load balance.

6
The given value of 30W per port is the maximum value referring to a single output. The total power
consumption should not exceed 120W when all PoE ports are being used. The increased demand for power is
particularly evident in the case of cameras with heaters or infrared illuminators - when launching these features, the
power consumption increases rapidly, which may adversely affect the operation of the switch. As the device is
designed for a continuous operation and is not equipped with a power-switch, therefore an appropriate overload
protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed about the method
of unplugging (usually through assigning an appropriate fuse in the fuse-box). The electrical system shall follow
valid standards and regulations.
2.2. Installation procedure
1. Before installation, cut off the voltage in the 230V power-supply circuit.
2. Mount the PSU in a selected location and connect the wires.
3. Connect the power cables (~230Vac) to L-N clips of the PSU.
The shock protection circuit shall be performed with a particular care, i.e. the yellow
and green wire coat of the power cable shall stick to one side of the terminal - marked
with ‘ ‘symbol on the PSU enclosure. Operation of the PSU without the properly
made and fully operational shock protection circuit is UNACCEPTABLE! It can cause a
device failure or an electric shock.
4. Connect the ground wire to the terminal marked with the symbol (power supply module connector). Use a
three-core cable (with a yellow and green PE protection wire) to make the connection. Lead the cables to the
appropriate clips through the insulating bushing of the connection board.
5. Connect the battery (mind the colours):
- battery output (+V): BAT+ cable / red,
- battery output (0V): BAT –cable / GND / black.
6. Connect the power (~230V).
7. Connect the camera cables to the RJ45 connectors (PoE connectors) and connect the recorder to the network
(the UPLINK connector).
8. Connect the power supply of the DVR (by default, the device is equipped with a cable terminated with the DC 2,1/5,5
plug).
9. Check the optical indication of the switch operation.
10. After installing and checking proper working, the enclosure can be closed.
Connection schemes

7
3. Indication of the device operation.
3.1 LED indication of operating status.
The PSU is equipped with two diodes on the front panel:
RED LED:
on –the PSU is supplied with 230V AC
off –no 230V AC supply
GREEN LED:
on –DC voltage in the AUX output of the PSU
off –no DC voltage in the AUX output of the PSU
3.2 Optical indication of the switch operation (see Table 8).
Table 8. Indication of the switch operation
OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY
GREEN LED LIGHT (Power)
Indication of the switch's
power supply
OFF –no power supply of the switch
ON –power supply on, normal operation
OPTICAL INDICATION OF THE PoE SWITCH's (1÷8)
GREEN LED LIGHT (PoE)
Indication of the PoE power
supply at the RJ45 ports
OFF- no power supply at the RJ45 port (the device is not connected or not compliant
with the IEEE802.3af /at standard)
ON –supply at the RJ45 port
Blinking –short-circuit or output overload
YELLOW LED LIGHT (LINK)
The connection status of LAN
devices, 10/100/1000Mb/s
and data transmission
OFF- no connection
ON - the device is connected; 10/100/1000Mb/s
Blinking –data transmission
OPTICAL INDICATION AT THE UPLINK PORTS
GREEN LED LIGHT
OFF- no connection/ the device is connected 10/100Mb/s
ON –the device is connected 1000Mb/s
YELLOW LED LIGHT (LINK)
The connection status of
LAN devices,
10/100/1000Mb/s
and data transmission
OFF- no data transmission
ON - the device is connected 10/100/1000Mb/s
Blinking –data transmission

8
Installation example of the SG108-CRB with batteries and the recorder
(DVR and accumulators are not included)
4. Operation and use.
4.1 Overload or short circuit of the PSU output (SCP on).
In case of overload, the output voltage is automatically shut off, and so is the LED indicator. The restoration of the voltage
takes place immediately after the failure (overload) is over.
4.2 Disconnection of discharged battery.
The PSU is equipped with the discharged battery disconnection system. During the battery-assisted operation, reducing
voltage below 19V at the battery terminals will cause battery disconnection.
4.3 Maintenance.
Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply
network. The PSU does not require performing any specific maintenance measures, however, in case of significant dust rate,
its interior is recommended to be cleaned with compressed air. In case of fuse replacement, use a replacement of the same
parameters.
WEEE LABEL
Waste electrical and electronic equipment must not be disposed of with normal household waste.
According to the European Union WEEE Directive, waste electrical and electronic equipment should
be disposed of separately from normal household waste
.
The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the
applicable law.
Pulsar
Siedlec 150, 32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: biuro@pulsar.pl, sales@pulsar.pl
http:// www.pulsar.pl, www.zasilacze.pl
Table of contents
Other Pulsar Switch manuals

Pulsar
Pulsar SG108-C User manual

Pulsar
Pulsar S-108 User manual

Pulsar
Pulsar S64-BR User manual

Pulsar
Pulsar RSUPS98R User manual

Pulsar
Pulsar PSBSOF 10A12 User manual

Pulsar
Pulsar PSB-251215 User manual

Pulsar
Pulsar SG64H User manual

Pulsar
Pulsar SWB-60 User manual

Pulsar
Pulsar RSFUPS116 User manual

Pulsar
Pulsar S64 User manual

Pulsar
Pulsar RSUPS98 User manual

Pulsar
Pulsar SF108 User manual

Pulsar
Pulsar RS54 User manual

Pulsar
Pulsar S64-CRB User manual

Pulsar
Pulsar SFG10F8 User manual

Pulsar
Pulsar ISF108 User manual

Pulsar
Pulsar SG108-C User manual

Pulsar
Pulsar S94-CR User manual

Pulsar
Pulsar S98-C User manual

Pulsar
Pulsar S108-CR User manual