2. Installation
2.1. Requirements
The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative
humidity (RH=90% maximum, without condensation) and temperature from -10°C to +40°C. Ensure the free flow of air around
the unit. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the
enclosure.
The switch load balance should be done before installation. Depending on application, appropriate power supply should
be selected - 52 V recommended. The given value of 30 W per port is the maximum value referring to a single output.
In case of full occupation of the PoE ports, the overall power intake should not exceed 240 W and depends on the current
efficiency of the PSU, taking account of the power intake for the own needs of the device The increased demand for power is
particularly evident in the case of cameras with heaters or infrared illuminators - when launching these features, the power
consumption increases rapidly, which may adversely affect the operation of the switch. As the device is designed for a
continuous operation and is not equipped with a power-switch, therefore an appropriate overload protection in the power supply
circuit should be provided. The electrical system shall be made in accordance with applicable standards and regulations.
2.2. Long Range mode
Switch enables operation in two modes: standard and extended range. When the Long Range switch is in STANDARD
position (see Fig. 5), PoE ports operate at 100 Mb/s up to 100 meters. After switching to EXTEND position, range is increased
to 250 meters and speed is reduced to 10 Mb/s. In both modes, the UpLink port speed is 1000 Mb/s.
Note: Changing the modes requires a power restart!
2.3. Installation procedure
1. Connect the 230 V power supply and turn on the device. The connection should be made with the supplied 3-core cable
with a plug. The place and method of installation of the switch should ensure free air flow around the unit.
2. Connect the camera wires to the RJ45 connectors (sockets RJ45 from 1 to 24).
3. Connect the remaining LAN devices to RJ45 (G1 and G2).
4. Check the optical indication of switch operation (see Table 3).
Connection schemes: