Table 5. Mechanical parameters
W=525, H=680, D+D1=165+14 [+/- 2 mm]
W1=530, H1=685 [+/- 2 mm]
The dimensions of the recorder
compartment
W2=400, H2=345, D2=80 [+/- 2mm]
The dimensions of the battery
compartment
Steel plate, DC01 1,0mm color white RAL 9003
Cheese head screw x 2 (at the front)
The possibility of installing two locks with different codes.
Power supply of the cameras: RJ45 socket
Power supply for recorder: DC2,1/5,5 plug
battery output BAT: 6,3F-2,5
TAMPER output: wires
Table 6. Operation safety
Protection class PN-EN 609501:2007
Protection grade PN-EN 60529: 2002 (U)
Electrical strength of insulation:
- between input and output circuits of the PSU
- between input circuit and protection circuit
- between output circuit and protection circuit
3000 V AC min.
1500 V AC min.
500 V AC min.
Insulation resistance:
- between input circuit and output or protection circuit
Table 7. Operating parameters
20 %...90 %, without condensation
Vibrations during operation
Impulse waves during operation
Vibrations and impulse waves during transport
According to PN-83/T-42106
2. Installation
2.1. Installation procedure
The device shall be mounted in confined spaces, according to the environment class II, with normal air humidity
(RH=90 % max. without condensation) and the temperature from -10 °C to +40 °C. Ensure the free flow of air around the unit.
The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the
enclosure.
Before installation, prepare a Switch'a load balance. The given value of 30 W per port is the maximum value referring to a
single output. The total power consumption should not exceed 192 W. The increased demand for power is particularly evident
in the case of cameras with heaters or infrared illuminators - when launching these features, the power consumption increases
rapidly, which may adversely affect the operation of the switch. As the device is designed for a continuous operation and is not
equipped with a power-switch, therefore an appropriate overload protection shall be guaranteed in the power supply circuit.
Moreover, the user shall be informed about the method of unplugging (usually through assigning an appropriate fuse in the
fuse-box). The electrical system shall follow valid standards and regulations.