Pump Alarm Cellular Alarm Instruction Manual

Quick Start Installation Guide
Copyright 2017, PumpAlarm.com, All Rights Reserved
Cellular Alarm

Please scan the image on the right with your
smartphone to view our installaon video, or
simply visit the link below.
www.pumpalarm.com/installaon
Need more guidance?
For technical support please call : 1-888-454-5051
Hours: M-F 8a-5p EST
The following items are available to you at pumpalarm.com:
• In Depth User Manual
• Installaon Video
• How it Works Video
• Online Store (where you can buy addional units and accessories)
PumpAlarm.com
203 W Morris St.
Indianapolis, IN 46225
888-454-5051

Components:
1. Cellular Alarm Unit
2. Hose Clamps (2)
3. Mounng Straps (4)
4. AA Baeries (4)
Oponal Sensors :
A. Water Sensor
B. Tilt Switch
C. Single Float Switch
D. Dual Float Switch
*See PumpAlarm.com for our
most up-to-date list of sensors.
Missing or Damaged Components?
Call PumpAlarm.com
888-454-5051
M-F 8:00a-5:00p EST
Do not return product to retail locaon.
1. 2.
3.
A. B. C. D.
4.

1. Status Light - Indicates the cellular status of your unit. Refer to the online manual
at pumpalarm.com for a descripon of the blink paerns.
2. Low Baery and Temperature Light - 2 red blinks indicates the backup baeries
are low. If the red light is ashing it indicates the baeries are crically low. When
the green light is ashing it indicates the Temperature Alarm. Refer to the online
manual at pumpalarm.com for a descripon of the blink paerns.
3. ON/OFF/MUTE - Press the buon 1 me to mute the device and 1 me to unmute
the device. Press and hold for 3 seconds to ON/OFF.
4. PUSH TO TEST - Press the buon 1 me to test device and receive a text message.
Hold the Test Buon to congure. Tap the Test Buon to test.
5. Input LEDs: 1 - 2 - LEDs blink when the associated inputs 1 and 2 are triggered.
6. Input LEDs: 3 - 4 - #3 input LED blinks when the lower oat is triggered and #4
blinks when the upper oat is triggered.
7. Sensor Input Connectors -
A. Inputs 1 and 2 are 2-pin, dry contact closure. Can be customized for
Normally Open or Normally Closed.
B. Inputs 3 and 4 are ed together as a 3-pin, for use with our dual oat and
sewage oat.
Geng to Know Your Device:

1
2
3
4
5
7A
67B
7
Unit Label

Mount the Cellular Alarm to a wall or pipe. Use mounng template below. It is the
correct dimensions for mounng the product. Mark the points using a pencil, then
use a 3/16” drill bit to make your holes. Apply the red anchors, and screws. Place
Cellular Alarm on the wall.
4.56”
xx
Mounng Template
Mounng Hardware and Sensors

Mount the device to a pipe using the mounng brackets (hose clamps).
Hose Clamps
Connect your choice of sensor into one of the inputs on the boom of the unit. We
recommend using the oat switch, or dual oat switch for sump pump applicaons
and the digital water sensor for oor or drain applicaons.

Please acvate your unit. Visit : www.pumpalarm.com/acvate.
Enter the 6 digit alphanumeric unit number found on the side of the unit. Then your
billing informaon.
This generates the phone number for your unit as well. Save this phone number as a
contact in your phone.
Install (4) AA baeries by opening the baery door on the back of the unit. Align the
negave (-) end of the baery to the spring in each holder.
Activate Online
www.pumpalarm.com/activate
PumpAlarm.com/activate
Phone #: (555)123-4567
add
photo
Cellular Alarm
Last
Company
Mobile
iPhone
(555)123-4567
Side of Unit
UNIT
ID 123ABC
1Unit Acvaon and Power On
AInstall Baeries

Plug the device into a 110V A/C outlet to power your unit on. Once the status light
turns solid green, press and hold the “Push to Test/Hold to Congure” buon for 3
seconds. Unit will chirp twice and status light will blink red & green. This will get the
unit ready to receive text messages from your cell phone. In the next step, you will
congure the unit by sending it text message commands.
Solid Green Light
BPower Device On
Caller ID and Conguraon Mode
If no phone numbers are configured in the unit, it will accept commands from any
phone number. Once a phone number is configured in the unit, only commands
from phone numbers configured in the unit will be processed.
The unit can be placed in Config Mode by pressing and holding the Mute button
until the status light (top light) changes to red/green blinking. This allows the device
to accept commands from any phone.

Using your mobile phone, create and send a text message to your device. Xis either
1,2, or 3for which phone number slot you would like to fill.
If you want text messages sent to addional phones, repeat this process. Your device
can hold up to three phone numbers.
phoneX [Phone Number]
Space
Adding phone numbers
Phone1 5557654321
2
A
Seng up Contact Phone Numbers
Adding phone numbers
Phone2 5557656778
For your main number, which
is phone1, you will send the
following message; replacing
5557654321 with your mobile
phone number.

Name your unit by sending the following message, replace John Doe
Residence with the name you’d like to use, up to 20 characters long:
If successful, the unit will chirp twice and you will receive a text message to the
phone number you just entered. See online manual if this step is not successful.
name [Unit Name]
Unit Settings
Name: Your Alarm
Phone1: 5557654321
Phone2:
Phone3:
Naming the unit
Name John Doe
Residence
B
Space
Name Unit
3

If successful, the unit will chirp twice and you will receive a text message with the
current sengs. See online manual if this step is not successful.
Seng Up Your Temperature Alarm
If the temperature falls below the low threshold a “low temp condition” message
is sent. If the temperature rises above the high threshold a “high temp conditon”
message is sent. When the temperature returns to the range between the low and
high thresholds, a “normal temp condition” is sent. The temperature sensor has an
accuracy of +/- 5 °F.
There are two (2) degrees of hysteresis required to return to normal. Example: if the
low threshold is 30°F, the temperature must go up to 32°F before it is considered to
have returned to normal.
A
Unit settings
Name: John Doe Residence
Phone1: 5557654321
Phone2:
Phone3:
5

Atemplow [°F]
Space
Use as a Heating System Alarm
We recommend setting your low
temperature threshold to around 48°F
and if away from the property, keep
your thermostat at least 6°F warmer
than you set the low threshold to
account for accuracy of sensor.
B
Send the unit a message with the following command. The 39 below should be
replaced with the degrees F that you wish to have an alarm trigger.
Conguring Low Temp
Temp low
TempLow 39
If successful, the unit will chirp twice and you will receive a text message with the
current sengs. See online manual if this step is not successful.
Setting display
PwrDelay:
TempLow: 39 degF
TempHigh:
Silent:

temphigh [°F]
Space
C
D
Temp high
TempHigh 85
Send the unit a message with the following command. The 85 below should be
replaced with the degrees F that you wish to have a high temp trigger.
Conguring High Temp
If successful, the unit will chirp twice and you will receive a text message with the
current sengs. See online manual if this step is not successful.
Setting display
PwrDelay:
TempLow:
TempHigh: 85 degF
Silent:

Space
Space
templow none -OR-
temphigh none
Temp none
TempHigh none
You may want to remove the temperature alarm functionality. You can remove the
high and low thresholds individually by sending either of the commands above.
Clearing Temperature
If successful, the unit will chirp twice and you will receive a text message with the
current sengs. See online manual if this step is not successful.
Setting display
PwrDelay:
TempLow:
TempHigh: none
Silent:
E
F

6
A
Basic conguraon is now complete. Press the “TEST” buon on the front of the
device to invoke a text message.
If successful, the unit will chirp twice and you will receive a text message with the
current sengs. See online manual if this step is not successful.
TEST
Tesng Your Unit
Test notication
John Doe Residence is oper-
ating correctly at 8:55AM on
09/23/2017

Customizing Inputs
Input Names
By default inputs are labeled generically in notification messages from the device. i.e.
input #1, input #2, etc. You have the ability to give the input a more descriptive name,
i.e. sewage sensor.
Input Alert Delay
Your device allows adjustment of the time delay on input alarm triggers and on
power outage detection. It will wait the specified amount of time (in seconds) before
sounding the alarm and sending out text message alerts. The power outage detection
is a silent alert, meaning only text messages are sent when an outage is detected after
the specified time delay, there is no sounder.
Contact Closure Type
Your device allows the adjustment of contact closure types, either Normally Open or
Normally Closed. The device defaults to Normally Open for all 4 inputs. All inputs are
dry contact, meaning they require non-powered sensors and can detect only an open
or a closed contact.
To allow for maximum flexibility in your particular application, we give you the ability
to customize every part of the input alert. We briefly discuss below and go into
greater detail on how to complete the setup in the following steps.
Basic Setup is Now Complete!
If you received your test notification, then basic setup of your unit is complete. On
the following pages, we have included setup instructions for the more advanced
features your unit has to offer. These include customizing individual inputs, power
outage delays and silencing your device.

Naming Input
Input1 oat switch
Seng Up Your Custom Input Name
You can give the input a more descriptive name. Where the Xis replaced with
the input number 1,2,3, or 4, and the [input name] is replaced with your
descriptive name.
Input Name
Inp1: oat switch, NO, 1 sec
Inp2: Input 2, NO, 1 sec
Inp3: Input 3, NO, 1 sec
Inp4: Input 4, NO, 1 sec
If successful, the unit will chirp twice and you will receive a text message with the
current sengs. See online manual if this step is not successful.
7
A
inputX [input name]
Space

Your device allows customization of the time delay on input alarm triggers. Xis either
1,2,3, or 4for the specific input you’re trying to update.
delayX [Seconds]
Space
Input delay
Delay1 30
Seng Up Input Alert Delay
8
Input delay
Inp1: Input 1, NO, 30 sec
Inp2: Input 2, NO, 1 sec
Inp3: Input 3, NO, 1 sec
Inp4: Input 4, NO, 1 sec
If successful, the unit will chirp twice and you will receive a text message with the
current sengs. See online manual if this step is not successful.
A

Your device allows the adjustment of contact closure types, either Normally Open
(no) or Normally Closed (nc). Xis either 1,2,3, or 4.
ctypeX nc -OR-
ctypeX no
Space
Space
Contact closure types
Ctype1 nc
Seng Up Contact Closure type
Contact closure types
Ctype1 no
Contact closure type
Inp1: oat switch, NC, 30 sec
Inp2: Input2, NO, 1 sec
Inp3: Input3, NO, 1 sec
Inp4: Input4, NO, 1 sec
If successful, the unit will chirp twice and you will receive a text message with the
current sengs. See online manual if this step is not successful.