CLEANING & MAINTENANCE
This is a graphic
representation of lters
01. Switch Assembly
02. Front Panel with Clad
03. Spout
04. Drip Tray with Cover
05. Sediment lter
06. Inlet water tube
07. Diverter
08. Ball valve
1. After installation and GKK change, discard 5L~10L ( 3-5 mins) before you start using
your purier.
2. Please keep spout plug closed when device is not in use for dispensing water.
3. Please open the spout plug when dispensing water.
4. If you are out of home, switch-o the purier and turn-o the Ball Valve.
5. Ensure the input water temperature is between 10°C and 40°C. Do not connect the
purier to any geyser, heater etc.
6. Ensure that the area around and beneath the purier is kept clean at all the time.
Ensure that this area is free of ants/insects/other pests.
7. Don’t drop any of the components, or the purier as a whole from a height. This may
cause the components to fracture or break, and the guarantee of getting water‘ As
safe as boiled water’ will no longer be valid.
1. The purier should be installed by a trained Pureit technician.
2. Pureit Classic UV+ G2 has to be installed on the wall. In case you are using it in a table
top condition, please either place its back touching fully on wall or otherwise hold it
when you are operating any switch.
3. Do not install the purication unit where it could freeze.
4. Do not use an extension cord.
5. Please ensure that the purier is not installed near a cooking range.
6. Do not install the purier above an electric socket.
7. Avoid sharp bends to the tube that is connected to the purier.
8. Install the purier away from the sunlight.
INSTALLING YOUR PUREIT CLASSIC UV+ G2
TAKING CARE OF PUREIT CLASSIC UV+ G2
1
2
3
KEEP YOURSELF SAFE
4
1. Do not plug or unplug the power cord with wet hands. Ensure the plug isn’t wet while
plugging in, or plugging out to avoid risks such as electrical shocks or re. Plug the
power cord in the right size socket to avoid sparks.
2. Do not try to open the purier for any reason. This can be done only by the qualied
company personnel or authorized agent.
3. If the power cord is damaged, it must be replaced and not used.
4. Do not light candles / diya on the purier. Do not keep heavy or sharp objects, e.g.
Radio etc. on the purier.
5. In case you notice any smoke or burning smell from your purier, please switch o the
power, unplug the cord, turn-o Ball Valve and call us at 1800-210-1000.
6. Please dispose the used consumables like the Germkill Kit along with the other
household waste through the municipal disposal system.
7. Do not use water not intended for drinking in Pureit System e.g. from abandoned or
abused water bodies or water resources in which human, animal or industrial wastes
are disposed or water that is extremely acidic or alkaline.
8. The output water may continue to have ora which is harmless and pose no health
hazard to the normal healthy adults and children.
9. Always rely on the Advance Alert SystemTM warning to change the Germkill Kit (GKK).
Auto Shut-o is the only additional assurance of safety.
10. Never buy Classic UV+ G2 or the Germkill Kit (GKK) or spares from an unauthorized
source. Always call on 1800-210-1000 and we will deliver and install a new GKK at your
home.
•
P
U
R
E
I
T
C
U
S
T
O
M
E
R
C
A
R
E
N
O
•
KNOW YOUR PUREIT CLASSIC UV+ G2
PUREIT CLASSIC UV+ G2’S UNIQUE TECHNOLOGY
1. Sediment Filter (SF) (Raw Water Processor)
Removes ne and coarse particulate impurities/ dirt and improves life of the Carbon Filter.
2. Activated Carbon Filter
Removes chlorine and organic impurities like harmful pesticides. It also adsorbs bad taste
and odour-causing organic compounds from water.
3. Mesh Filter
Ensures that no suspended/dirt particles enter the UV chamber.
4. High Intensity UV Chamber
High intensity UV rays ensure maximum UV intensity for inactivation of bacteria, virus and
parasites to deliver safe water always.
1. You can clean the device by using disinfectants like bleach/hypochlorite ( 50 ppm
available chlorine ). Discard 2 litres of water after cleaning the tap.
2. External portion of the purier must be cleaned using wet cloth only. Do not use any
detergent or soap.
Disposal Guidelines (Electrical): To prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate electrical items in this product such as power supply adaptor, control circuits, LED
panel, and wiring from other types of waste and recycle them responsibly to promote sustainable use of material
resources. Contact either the retailer where you purchased this product, or local government oce for details of
where and how these items can be taken for environmentally safe recycling.
Rotate the housing clock-wise and
remove it completely from the cap
Take out the Sediment Filter
from the housing
Clean the Sediment
Filter under jet of water.
rub by hand / tap gently
to clean.
After cleaning the
lter, put it back in
the housing.
Insert the housing inside the cap & rotate
it anticlockwise to engage the threads.
Ensure the housing is tightened till it’s
original marking.
SF (Sediment Filter)
ATTENTION
• Close the ball valve before opening SF housing for cleaning.
• The housing needs to be opened in wall mounted position only.
• Make sure the clamp is properly xed on the wall & cap of housing.
• Keep the cap mounted on the wall. No need to remove the same.
• Please do not use any abrasive / pointed tool to clean the Sediment
Filter as it may damage the Sediment Filter.
• In case you observe the rubber ring is dirty, clean the rubber ring &
x it on the housing again properly.
• Clean the inner portion of the housing as well.
• If required, a Spanner for opening ESF housing can be bought from
Pureit service technician.
6
7
8
2
4
5
3
1
UNIQUE FEATURES OF PUREIT CLASSIC UV+ G2
* Based on 10 litres of water consumption per day.
High Intensity UV Lamp
Powerful 11 W UV lamp for enhanced safety.
Advanced 4-stage Purication
Advanced 4-stage purication that ensures that every drop of water
from your Classic UV + G2 is pure & safe to drink.
Fresh Water Always
The device doesn't store any water, hence you always get fresh,
safe water to drink.
Double Purity Lock
Advance Alert System warns you 15 days* in advance when your
purier will stop working.
Auto Shut o stops water ow when GKK life expires.
USEPA standards on Purication
Meets stringent criteria of Environmental Protection Agency,
EPA (USA) for harmful virus and bacteria removal.
Water Saving Mode
If you leave the device unattended and water dispensing is on, water
may get wasted. With this feature dispensing will stop automatically after
15 minutes of continuous dispensing.
Compact, Sleek and Covered design
Optimises space and looks good in modern kitchen.
Power Saving Mode
If you are not dispensing water from device, UV lamp will shut-o after
10 minutes.
No AMC
Lower cost of maintenance.
Advanced Voltage Fluctuation Guard
Protects your purier from sudden voltage uctuation ranging between
165 and 280Va.c
4
3
2
1