Quasar Biotech MD BLUE User manual

BLUE
PLEASE READ ALL INSTRUCTIONS BEFORE USE
INSTRUCTION MANUAL
!
B
L
U
E
L
I
G
H
T
C
L
A
R
I
F
Y
I
N
G
S
Y
S
T
E
M
Copyright © 2013 Quasar Bio-Tech Inc. All Rights Reserved

BLUE LIGHT THERAPY .............................................................................. 1
MAKING ACNE SING THE BLUES ........................................................... 1
INDICATIONS FOR USE.............................................................................. 1
QUASAR MD BLUE DESCRIPTION.......................................................... 2
TREATMENT INFORMATION.................................................................... 2
BEFORE TREATMENT – SETUP............................................................... 2
TREATMENT PROCEDURES..................................................................... 3
QUASAR MD BLUE CARE INSTRUCTIONS .......................................... 4
RISKS & BENEFITS OF QUASAR MD BLUE TREATMENT.............. 5
WARNINGS..................................................................................................... 5
PRECAUTIONS FOR BEST RESULTS..................................................... 6
DECLARATION OF CONFORMITY........................................................... 6
WARRANTY INFORMATION ..................................................................... 7
QUESTIONS AND CONCERNS ................................................................. 8
CONTACT US.................................................................................................. 9
CONTENTS

1
CONTENTS
INTRODUCTION
BLUE LIGHT THERAPY
Thank you for buying your Quasar MD Blue. Doctors all over
the world use our device for treating acne. A natural and more
effective form of treating breakouts and blemishes, blue light
therapy works by killing the acne-causing bacteria, P. Acne. You
can use your Quasar MD Blue for blue light treatment of mild to
moderate inflammatory acne (acne vulgaris) in the privacy of your
own home. Manufactured out of medical grade components, your
Quasar MD Blue will provide you with years of effective use, backed
by our five-year warranty.
MAKING ACNE SING THE BLUES
Most people suffer from acne at some time in their life. Acne results
when the body produces an over abundance of sebum: a thick, oily
substance within the pores. When the pores clog, pimples, redness
and inflammation occur on the surface of the skin. Research shows
that blue light therapy can help clear your skin by killing the acne
causing bacteria. Use daily or as needed. You should see fewer
pimples and reduced redness within four (4) weeks.
INDICATIONS FOR USE
The Quasar MD Blue is indicated for treatment of mild to moderate
inflammatory acne. Mild to moderate inflammatory acne is inflamed,
red pimples or pustules, with or without blackheads
or whiteheads.
The Quasar MD Blue may not achieve desired results if you have
severe acne. Severe acne means widespread nodular or cystic
acne. If you are suffering from severe acne, see your healthcare
professional for medical treatment.

2
QUASAR MD DESCRIPTION
Your Quasar MD has a hand piece and a wall power unit. It has a six
(6) foot cord that you plug into the end of the hand piece. It provides
red and infrared light to treat your face and body. It is small, easy to
use, and will last many years with normal use.
The MD hand piece contains both red and
infrared LED bulbs. They send out a special
type of natural light. The back has a button
for picking the mode: non-pulsed, slow
pulse, and fast pulse.
5
MD Hand Piece
Wall Mount
Power Unit
Power Connector On Button
6 - Foot
Power Cord
Wall Mount Power Unit
6 – Foot Power Cord
QUASAR MD BLUE DESCRIPTION
TREATMENT PROCEDURES
Each Quasar
includes an optional
clear protective
lens for cleanliness
Quasar MD Blue
Hand Piece
TREATMENT INFORMATION
BEFORE TREATMENT – SETUP
Snap the plastic protective lens cover onto the front face of the
device. It should t snug.
You should use the Quasar MD Blue on a daily basis for optimal
results. Your treatment schedule may vary due to skin type or skin
condition. You should continue treatments as long as you have
acne, redness, and pimples. You may use the Quasar MD Blue on
your face and other areas of your body where you have acne. The
Quasar MD Blue is for mild to moderate inflammatory acne and
results have not been tested with severe acne.
Your Quasar MD Blue uses a 12v power supply
that plugs into an electrical outlet on your wall.
Plug the power unit into bottom of your Quasar MD Blue hand piece
and then into the wall outlet. The power jack should fit firmly
into the hand piece. Use only the power unit that comes with your
Quasar MD Blue. If you lose the power unit or the power unit is
damaged, contact us at (800) 944-1523 for a replacement.

3
10
USE
SMALL
CIRCULAR
MOTIONS
TREATMENT PROCEDURES
TREATMENT INFORMATION
BEFORE TREATMENT – SETUP
Snap the plastic protective lens cover onto the front face of the
device. It should t snug.
Your Quasar MD Blue uses a 12v power supply
that plugs into an electrical outlet on your wall.
FOLLOW THESE DIRECTIONS:
TREATMENT PROCEDURES
3
2
1Cleanse and dry your skin before treatment.
Press the ON/OFF button to turn the device on.
4
When treating your entire face, divide your face into
four sections. Refer to the diagram below.
Keep the Quasar MD BLUE in contact with your skin and gently
glide it over each section in small, circular motions, for a total
of four (4) minutes.
Repeat in all sections for a total
of sixteen (16) minutes.
Treat using the Quasar MD BLUE
one (1) to three (3) days per
week or as needed for optimal
results.
When done, turn o the
device, and refer to the
Care Instructions.

4
QUASAR MD BLUE CARE INSTRUCTIONS
Always clean your Quasar MD Blue after each use in order to
reduce bacterial growth on the device. Unplug your Quasar MD
Blue, then use a damp (not wet) cloth or alcohol swab to wipe the
surface of the plastic lens where it has made contact with your
skin. You may also remove the lens to clean it. Replace when dry.
DO NOT clean your Quasar MD Blue with heat. It can break the
device.
DO NOT put your Quasar MD Blue in any liquids.
DO NOT sterilize by any heat method.
DO NOT put your Quasar MD Blue in a microwave oven.
Always store your Quasar MD Blue in a cool, dry place. Excessive
moisture can cause corrosion.
Your Quasar MD Blue has no parts you can replace or fix.
Please do not try and repair it.
If your Quasar MD Blue is not working, call Quasar Bio-Tech, Inc.
at (800) 944-1523 or (941) 306-5812 for assistance.
CARE INSTRUCTIONS
Your Quasar MD Blue has no parts you can replace or fix.
Please do not try and repair it.
WARNINGS

5
RISKS & BENEFITS OF QUASAR MD BLUE
TREATMENT
Use the Quasar MD Blue for treating mild to moderate inflammatory
acne.
The principle benefit is a reduction in inflammatory acne.
CARE INSTRUCTIONS
RISKS AND BENEFITS
!
A study of user data found no users reporting negative side effects
such as redness or pain from the light. The study did not research
the results of incorrect use, such as using the light too long.
EVENT HARM
EVENT
LIKELIHOOD
HARM
LIKELIHOOD
Treating following
the instructions
Treating an area
more than 4 minutes
Used for treatment
not recommended
Unknown
Unknown
Unknown Unknown Unknown
New skin redness
lasting 2+ hours
Pain in treatment area
< 1% users
reported harm
< 1% users
reported harm
New skin redness
lasting more than 2+ hours.
Pain in treatment area.
WARNINGS
!
DO NOT USE the Quasar MD Blue in water (including your sink,
bath, or shower). You could get an electric shock.
DO NOT USE the Quasar MD Blue if it has fallen into water or other
liquids, even though it may appear dry. Water can damage the
device and you could get an electric shock.
DO NOT USE
the Quasar MD Blue if the wall power unit has a frayed
cord or the prongs are bent or loose. You could get an electric shock.

6
WARRANTY INFORMATION
PRECAUTIONS
PRECAUTIONS FOR BEST RESULTS:
Always check your Quasar MD Blue before using. Test the unit by
seeing that the blue LEDs are working. Please, only glance at the
blue light from the side, NOT straight on. Please DO NOT stare at
the blue light.
Always clean your Quasar MD Blue after each use. Unplug your
Quasar MD Blue, use an alcohol pad and gently wipe the surface of
the LEDs and let air dry. A dirty LED can block light to your skin and
your Quasar MD Blue will not work as well for you.
USE ONLY the power unit that came with your Quasar MD Blue.
Other power units will damage your Quasar MD Blue.
DECLARATION OF CONFORMITY
The Quasar MD Blue meets international lamp safety standards.
The Quasar MD Blue has outputs below the recommended
Maximum Permissible Exposure.

7
WARRANTY INFORMATION
PRECAUTIONS
WARRANTY INFORMATION
Please ll out your warranty card and return it to Quasar
Bio-Tech, Inc
.
Your Quasar MD Blue is warranted free from
defect in material and workmanship for a period of five (5) years
after its original purchase date under normal use. This warranty
extends to all Quasar MD Blue owners who can provide proof of
date of purchase. If the product becomes defective within the
warranty period, contact Quasar Bio-Tech, Inc.
North America, call toll free (800) 944-1523 for repair or
replacement. Outside of North America, call (941) 306-5812.
Contact information can be found at www.quasarbiotech.com.
Quasar Bio-Tech, Inc.
reserves the right to replace a defective
product with the most comparable product currently available. Your
exclusive remedy for any defective product covered by this limited
warranty is
limited to the repair or replacement of the defective
product. Quasar Bio-Tech Inc.’s entire liability for any defective
product shall in no event exceed the purchase price for the
defective product.
Manufactured and sold in the USA by:
Quasar Bio-Tech, Inc.
Sarasota, FL 34243
(941) 306-5812

8
QUESTIONS AND CONCERNS
If you find that your Quasar MD Blue is not working as expected, do
not use it and do not attempt to fix it. There are no parts you can
fix or replace. Contact Quasar Bio-Tech, Inc.
CONTACT INFORMATION
QUESTIONS AND CONCERNS
PROBLEM POSSIBLE CAUSE ACTION TO TAKE
Only some blue lights
come on when the Quasar
MD Blue is switched on
Blue lights blink Interrupted power unit
Wall outlet, power unit,
or switch, is bad
Component bad
Switch bad
Wrong power unit
Quasar MD Blue does not
work, no lights come on
Quasar MD Blue does not
turn o or lights are dim
Switch does not work
Quasar MD Blue gives o
a burning smell or smoke
is seen
Check power unit and cord
for damage. Is the power unit
plugged in? Check that wall
outlet has power. If power is
on, contact Quasar Bio-Tech,
Inc. for instructions.
Check wall outlet has power.
Is power jack is securely in place?
Contact Quasar Bio-Tech, Inc.
for new power unit.
No power from wall outlet or
a component has gone bad
Check wall outlet for power.
Contact Quasar Bio-Tech, Inc.
for a new power unit.
Contact Quasar Bio-Tech, Inc.
for a new unit.
Contact Quasar Bio-Tech, Inc.
for a new unit.
Turn OFF unit immediately,
UNPLUG from wall.
DO NOT use unit again.
Contact Quasar Bio-Tech, Inc.

9
CONTACT INFORMATION
QUESTIONS AND CONCERNS
Turn OFF unit immediately,
UNPLUG from wall.
DO NOT use unit again.
Contact Quasar Bio-Tech, Inc.
CONTACT US
Quasar Bio-Tech, Inc. has skin care experts and technicians to answer
your questions. You may call our toll free or local number from 9 - 5
p.m., Monday through Friday, Eastern Standard Time, USA.
You may also email questions.
Please contact us:
Quasar Bio-Tech, Inc.
Airport Commerce Center
1431 Tallevast Rd. Sarasota, FL 34243
(800) 944-1523 (toll free)
(941) 306-5812 (voice)
(941) 306-5816 (fax)
inf[email protected]om
www.quasarbiotech.com
BATCH SERIAL NUMBER
Quasar MD Blue Product Specications are subject to change
without notice.
Quasar MD Blue Instruction Manual: LAB-059-A, 02/2013

LAB-059-A
Table of contents