Quest DEH 3000 Digital Control
Quest DEH 3000 Digital Control:
• Digitalcontrolofrelativehumidity
(DigitalSet-Point)
• Fan/Filteroperation
• Programmableventilationtimer
• Sleekdesign
• Large,easy-to-readbacklitLCDdisplay
• Hightemperaturecut-out
• Dryoutcycletimer
• Autoreboot
quest
quest

quest
quest 1-800-533-7533
2
www.QuestProtect.com
Quest DEH 3000 Installation, Operation and Maintenance Instructions
Table of Contents
1.Specications.................................................................. 3
2.Installation...................................................................... 3
2.1 InstallInstructions................................................... 3
2.2 Wiring.................................................................... 4
2.3 AuxiliaryRelayOperation....................................... 4
2.4 DehumidierLockout............................................. 5
2.5 Location................................................................. 6
2.6 Testing.................................................................... 6
3.Operation........................................................................ 7
3.1 Display................................................................... 7
3.2 Setting.................................................................... 7
3.3 On/OffSetting........................................................ 7
3.4 SettingClockTime.................................................. 7
3.5 SettingRelativeHumiditySetpoint.......................... 8
3.5AOperation....................................................... 8
3.6 FanSetting&Operation.......................................... 8
3.7 DamperOperationandSetting(Ventilation)........... 9
3.8 Intermittent/ProgrammedVentilation....................... 9
3.9 TemperatureCutoutProgramming........................ 11
3.10 DefaultSettings..................................................... 11

1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
3
www.QuestProtect.com
quest
quest
MountingHole
MountingHole
24VACYellowWire 24VACRedWire
Damper
WhiteWire
(Optional.See
warningbelow)
Dehumidier
BlueWire
Fan
GreenWire
ON-Detect
Common
OFF-Detect
NormallyOpen
Common
NormallyClosed
Optional
Use
Optional
Use
1. Specications
Part#(P/N) 4027370
Model: QuestDEH3000DigitalControl
Electrical: 24VAC
MaxCurrent–
DMP,COMP,FAN: 1Ampeach
HumidityRange: 10–95%RH,
±
5%
HumidityAccuracy:
±
5%
Output: 3Amps24VAC
Aux.RelayCapacity 5Amps
TempRange/ 30°-90°F,2%
Accuracy
Size 4.95"Lx1.06"Wx4.19"H
FOR HVAC INSTALLER ONLY:
2. Installation
InstalltheQuestDEH3000controlpanelinacentralareaofthe
structurewhereitwillsensetherelativehumidityofthestructure
accurately.Donotinstallthecontrolpanelwhereitmaynot
accuratelysensetherelativehumiditysuchasnearHVACsupply
registers,nearexteriordoorsandwindows,ornearapoolorspa.
Installinaccordancewithallapplicablecodesandstandards.
2.1 Install Instructions
1. Separatethefrontpanelfromthebackpanelbydepressing
themiddlesectionsofthetopandbottomofthefrontpanel.
2. Locatethewiringaccessholeinthe
wallorotheratmountingsurface.
Placethebackpanelintopositionand
drilltheappropriatemountingholes.
3. Insertthescrewsandtighten.Levelas
necessary.
4. Maketheelectricalconnectionstothe
terminalsonthebackpanelasshown
intheapplicablewiringdiagram(see
Sections2.2-2.4).
5. Testtheinstallation(seeSection2.5).
2.2 Wiring
WARNING! DO NOT ALLOW THE YELLOW WIRE FROM THE QUEST DEHUMIDIFIER
TO CONTACT THE RED OR WHITE WIRES FROM THE QUEST DEHUMIDIFIER, DAMAGE TO THE 24-VOLT
TRANSFORMER WILL RESULT.

quest
quest 1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
4
www.QuestProtect.com
WARNING! THE QUEST DEH 3000 DIGITAL CONTROL OPERATES ON A LOW VOLTAGE
CIRCUIT (24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE CIRCUIT.
WARNING! UNPLUG THE QUEST DEHUMIDIFIER BEFORE WIRING THE DEH 3000.
Theinstallermustsupplyalleldwiring,includingthewiringbetweentheQUESTdehumidierand
theQuestDEH3000.SomeofthecontrolwiresleavingtheQUESTdehumidiermaynotbeusedin
somecontrolsituationsandshouldbeleftdisconnectedwithwirenutstapedontothestrippedends.
BesuretoconsulttheelectricalschematicinthismanualortheinternalelectricalboxoftheQuest
dehumidierbeforemakinganycontrolconnections.
WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A
CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.
TheWhitewirecontrolstheoptionalmotorizeddamperthatcanbeinstalledintoafreshair
duct.Thisdamperprovidestheabilitytocontrolfresh
airventilationusingtheventilationtimerfunctionof
theQuestDEH3000andtheterminallabeled“DMP”
(SeeSection3.8).Leavethe“DMP”terminalunusedif
amotorizeddamperisnotused,andcapofftheWhite
wirefromtheQuestdehumidier.
Standard wire colors for thermostats are as follows:
Description Color Terminal code
24VAC Red R
CallforHeat White WorW1
ForceFanOn Green G
Compressor
CallforCooling Yellow YorY1
2.3 Auxiliary Relay Operation
Itmaybedesirabletocoordinatefanoperationofthe
centralheating/coolingsystemwithdehumidierfan
operation.TheQuestDEH3000containsarelaythat
providesthisability.
TherelayterminalslabeledNC,COMandNOoperate
accordingtothefollowingchart:
FAN COM to NO COM to NC
ON CONNECTED OPEN
OFF OPEN CONNECTED
NO
COM
NC

1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
5
www.QuestProtect.com
quest
quest
Commonuses(assumingstandardthermostatwiringcolorsasnoted):
Lock-out the A/C during dehumidier fan operation
ThiswillturnofftheA/Cwheneverthedehumidierfan
runs.
1.WiretheYellowthermostatterminaltotheNCterminal
ontheQuestDEH3000.Theinstallermustsupplythe
wiringbetweentheQuestdehumidierandthecontrol
panel.Besuretosafelyroutethecontrolwirestoprevent
damageduringinstallation.Becarefulnottocrossthe
wireswhenconnectingtheQuestdehumidierandthe
remotecontrolpanelordamagetothetransformermay
result.
2.RuntheYellowwirefromtheA/CunittotheCOM
terminalontheQuestDEH3000.
Energize the A/C central fan during dehumidier fan
operation
ToautomaticallyruntheA/CFANwhenthedehumidier
fanruns.
1.AttachasecondGreenwiretotheGreenfanwire
terminalonthethermostat.
2.ConnectthenewGreenwiretotheCOMterminalontheQuestDEH3000.
3.RunawirefromtheRedterminalonthethermostattotheNO
(NormallyOpen)terminalontheQuestDEH3000.
2.4 Dehumidier lock-OFF or lock-ON:
A/C sensor feature
Toautomaticallyactivateordeactivatethedehumidierwhentheair
conditionerruns.
Activate dehumidication when the air-conditioner is running.
A voltmeter is required for the next steps to ensure the correct wiring from
the A/C transformer is used to set up the Lock-in dehumidier function.
1.ThecommonwirefromtheexistingA/C
transformer(usuallyBlack)mustbeattachedto
the“COM”sensorterminalbetween“ON-D”and
“OFF-D”ontheDEH3000.
TIP: The common wire can be identied as the wire from
the A/C transformer that reads 0 volts between it and the
Yellow air conditioning call for cooling wire.The incorrect
wire will give a 20 to 28 volt reading.
2.AnotherYellowwiremustbeaddedtothe
thermostatYellowterminalandruntothe“OFF
D” sensorterminalontheQuestDEH3000.
A/C
Unit
Red
Green
Yellow
A/C
Unit
Red
Green
Yellow
A/C
Unit
Red
Green
Yellow
A/C
Unit
Red
Green
Yellow
ON-D
COM
OFF-D
TO A/C
TO A/C

quest
quest 1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
6
www.QuestProtect.com
Deactivate dehumidication when the air-conditioner is running.
Avoltmeterisrequiredforthenextstepstoensurethe
correctwiringfromtheA/Ctransformerisusedtosetup
theLock-outdehumidierfunction.
1. ThecommonwirefromtheexistingA/C
transformer(usuallyBlack)mustbeattachedto
the“COM”sensorterminalbetween“ON-D”
and“OFF-D”ontheDEH3000.
TIP: The common wire can be identied as the wire
from the A/C transformer that reads 0 volts between it
and the Yellow air conditioning call for cooling wire. The
incorrect wire will give a 20 to 28 volt reading.
2.AnotherYellowwiremustbeaddedtothethermostatYellowterminalandruntothe“OFF-D”
sensorterminalontheDEH3000.
2.5 Testing
Verifythewiringconnections.
WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A
CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.
Aftercheckingthewiring,thisshorttestwillconrmproperhook-up.
1. InstallfrontcoveroftheQuestDEH3000;connectthetoprst,thenthebottom.
2.PlugintheQUESTdehumidier.TheQuestDEH3000shouldpowerup.
3.TurntheQuestDEH3000ONbypressingthe“ON/OFF”button.
4.VerifydehumidicationoperationbyadjustingtheRH“SETPOINT”tobelowthe“%RH”reading
onthedisplay.Usethedown“RH”button.ConrmQuestfanandcompressoroperation.Both
shouldbeONnow.
IncreasetheRH“SETPOINT”onthedisplaytowellabovethe“%RH”readingonthedisplay.Pressthe“RH”up
arrowtoincreasetheRH“SETPOINT”.
AfterrunningthedehumidiercompressortheQuestDEH3000appliesa10minuterestartlockoutonall
functions.Youwillhavetowaitfortherestartlockouttoexpire.
5.VerifyFAN-onlyoperation:
a.Checkthe“VENT”modeonthedisplay,itwilleitherbe“CLOSED”or“OPEN”.Ifitis“CLOSED”gotothe
nextstep.Ifitis“OPEN”,pressandholdthe“VENT”keyuntil“OPEN”ashesonthedisplay,releasethe
keyandthenpressitonemoretime.“OPEN”willchangeto“CLOSED”.Don’ttouchthekeysforseveral
secondsuntilitstopsashing.
b.Pressandholdthe“FAN”buttonuntil“AUTO”beginsashingonthedisplay,releaseit,andthenpressit
againtoswitchthefantothe“ON”setting.
c.ConrmthattheQUESTfanisON.QuestcompressormustbeOFF.Ventilationdamper(ifused)shouldbe
CLOSED.
6.VerifyoptionalVENToperation(ifelectricdamperisinstalled):
a.Pressandholdthe“FAN”buttonuntil“ON”ashesonthedisplay.
b.Releasethe“FAN”button,thenpressitagaintoswitchfanoperationto“AUTO”.
TO A/C
TO A/C

1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
7
www.QuestProtect.com
quest
quest
c.Pressandholdthe“VENT”buttonuntil“CLOSED”ashesonthedisplay.
d.Releasethe“VENT”button,thenpressitagaintoswitchventmodeto“OPEN”.
e.ConrmthattheQuestfanisON.VentilationdamperisOPEN.QUESTcompressormustbeOFF.
f.Pressandholdthe“VENT”buttonuntilthe“OPEN”ashesonthedisplay.
g.Releasethe“VENT”button,thenpressitagaintoswitchventmodeto“CLOSED”.
Troubleshooting:
Ifanyfunctionsarenotworkingproperly,checkthewiringandconnections.Avoltmetermaybeusedacross
terminalstoverifyvoltage.Ifthereisconcernaboutthedehumidiernotoperatingproperly,theleadsexitingthe
QUESTdehumidiermaybeconnectedaccordingtothefollowingchart:
Wire connections Operation
Yellow&Blue Fan&Compressor
Yellow&Green FanOnly
WARNING!DO NOT MAKE ANY OTHER CONNECTIONS OR TRANSFORMER DAMAGE
MAY RESULT.
7.VerifyanyadditionaloptionalcontroloperationssuchasfaninterlockorA/Clockout.
8.ProceedtotheOperationsection.

quest
quest 1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
8
www.QuestProtect.com
FOR INSTALLER & OWNER:
3. Operation
Onthedisplayscreen,asolid“O”infrontofanyofthe3functions(SETPOINT,VENT,FAN)indicatesthe
functionisoperating.Aashing“O”indicatesitisinawaitmodeandnotavailableatthemoment.No“O”
indicatesthefunctioniscurrentlyOFF.
Solid“O”before Indicates
SETPOINT Dehumidieron
VENT Freshairventilationcycleinprogress
FAN Fanon
Waitmodeisafactory-programmedtimeperiodmeanttopreventshortcycles.Thisextendsthelifeofthe
dehumidier.Whenaashing“O”isencountered,theunitisinwaitmodeandIT COULD BE UP TO 10
MINUTES BEFORE OPERATION RESUMES.
3.1 Display
•Wheneverthereispowertothecontrol,itwilldisplaythetime,theday,%relativehumidity,and
temperature.
•WhenthecontrolisactuallyswitchedON,the%RHsetpoint,fanstatus,runmode(programorhold),and
freshairventilationstatusisdisplayed.
•Whenakeyispressedthedisplaywilllightforapproximately½aminute.
•TheTimeandDayisdisplayedatthetopofthescreen.
•RHandTemperaturearedisplayedinrealtime.
•Asolid“O”beforetheSETPOINT,VENT,ORFANindicatesthefunction
isoperating.
•Aashing“O”beforetheSETPOINT,VENT,ORFANindicatestheunitis
inwaitmode.
3.2 Setting
Duringtheset-upprocess,ifyoumakeamistake,simplycontinue.Youcanalwaysgobacktoadjustthe
settings.Ifyouleavethecontrolaloneanddon’ttouchanybuttonsfor10seconds,thecontrolwillremember
anychangesmadeandreturntothenormaldisplayscreen,allowingyoutoproceedtothenextstep.
3.3 Personal Settings reference list
Please record your settings here.
Function Factory setting My Setting
SETPOINT(%RH) 50%
VENT Closed
FAN Auto
TEMPCUTOUT 99°

1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
9
www.QuestProtect.com
quest
quest
3.4 On/Off and display items
Pressthe“ON/OFF”buttontoturnthesystemONorOFF.
WhenthesystemisON,thesetpoint,fanstatus,operationmode(RUNor
HOLD),andfreshairventstatusisdisplayed.
WhenthesystemisOFF,thecontrolwilldisplaythetime,day,%RH,and
temperature.
Whentheunitisshipped,itisinmanual(hold)mode.
3.5 Setting Clock Time
1.Pressandholdthe“CLOCK”button.Thehourdisplaywillash.Release
thebutton.
2.Usetheup/down“RH”buttonstochangethevalue.
3.Pressthe“CLOCK”buttonagainandtheminutedisplaywillash.Use
the“RH”buttonstochangethevalue.
4.Pressthe“CLOCK”buttonagainandAMorPMwillash.Usethe“RH”buttonstochangethevalue.
5.Pressthe“CLOCK”buttonagainandthedaydisplaywillash.Usethe“RH”buttonstochangethevalue.
6.Don’ttouchanybuttonsforseveralsecondsuntilthedisplaystopsashing,thiswillsaveyoursettings.Ifyou
needtochangeanythinggobacktostep#1.
3.6 Adjusting the relative humidity “SETPOINT”
TheQuestDEH3000sensestheambientrelativehumidity(%RH)ofthespaceinwhichitislocated,itcomes
factorypresettohold50%relativehumidity.
Therelativehumidity“SETPOINT”(desiredRHtobemaintained)operates
thedehumidierfunctionoftheQuestdehumidier.Ithasnoeffectonthe
optionalVENT(freshairventilation)orFAN(airrecirculation)functionsif
theyarebeingused.
Operation
Thestandardrangethatthedehumidierholdsaroundyour“SETPOINT”
is3%.Withasetpointof50%,thedehumidierwillrununtiltherelative
humidityreaches47%.Thedehumidierwillthenswitchoffuntilthe
relativehumidityreaches53%.
Ifthesetpointishigherthantheambientrelativehumidity,thespacedoesnotneedtobedehumidiedsothe
dehumidierwillnotrun.
Example:Setpoint:50%RH
Currentcondition:45%RH–Thedehumidierwillbeoff(no“O”indicatorwillbedisplayed).
Ifyoursetpointisbelowtheambientcondition,thedehumidierwillbeonand“O”willdisplay.
Example:Setpoint:50%RH
Currentcondition:55%RH–Thedehumidierwillbeon(“O”displayed).

quest
quest 1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
10
www.QuestProtect.com
3.7 Fan Setting and Operation
Usethe“FAN”buttontochangethefanoperation.Thereare2choicesforfanoperation:“ON”or“AUTO”.The
factorypresetis“AUTO”.
“ON”–ThefanintheQuestdehumidierwillruncontinuously.Thisdoesnotaffecteitherthedehumidication
orventilationfunctionsofthesystem.Thesystemmayormaynotbeventilatingordehumidifyingwhilethefanis
running.Thissettingiscommonlyusedformaximumairltrationand/orairrecirculation.
“AUTO”–IndicatesthefanwillrunwhentheQuestDEH3000callsfordehumidicationorventilation.Ifthe
controlhasnotcalledfordehumidicationfor3hours,thecontrolwillautomaticallyrunthedehumidierfan
for10minutes.
Afteradehumidicationcycle,thefanautomaticallyshutsofffor10minutes.Thispauseallowsthewaterto
drainfromthedehumidier.
Asolid“O”indicatesthefanisoperating.Aashing“O”indicatesthefanisinawaitmode.No“O”indicates
thefanisOFF.
Tosettheoperation:
1.Pressandholdthe“FAN”button.Thecurrentfansettingwillbeginto
ashonthedisplay.Releasethebutton.
2.Pressthe“FAN”buttontotogglebetweenthe“ON”and“AUTO”modes.
Withthefaninthe“AUTO”mode,thefanwilloperateonlywhenneeded
byotherfunctionsofthesystem.ThefanwillremainOFFunlessthesystem
isdehumidifyingorventilating.Thefanalwaysrunsduringdehumidication
andventilationandthefan“O”iconwillbelit.Tocompletelyturnthe
systemOFF,usethe“ON/OFF”buttonasdescribedearlier.
3.8 Damper Operation and Ventilation,
Manual (Hold) Mode
The“VENT”settingcontrolstheventilationfunctionofthesystem.Ithasnocontroloverthedehumidication
function.Inordertoprovideventilation,themotorizeddampermustbeopenandthefanmustberunning.
Thecontrollertakescareofthesetwofunctionsautomaticallysothatwheneverthedamperisopen,thefanis
running.
Theventilationindicator“O”willbedisplayedwhenevertheunitisventilating.Thefanoperationindicator“O”
willalsobelit.
Therearethreedamperoperationmodes:
1.“OPEN”–holdmode:Thedamperwillbeopenandthedehumidierfanwillbecontinuouslyoperatingto
introducefreshairintothespace.Usethismodeforcontinuousfreshairventilation.Thefanisalwayson
whenthedamperisopen.
2.“CLOSED”–holdmode:Thedamperwillneveropen,andthedehumidierwillnotventilate.Thefanwillstill
operatenormallyforrecirculationanddehumidication.
3.“PROGRAMMED”mode:TheQuestDEH3000willoperatethemotorizeddamperandthedehumidierfan
accordingtotheprogrammedventilationschedule(Section3.9).
Thefactorypresetforthe“VENT”settingis“CLOSED”.
Toset“OPEN”–holdor“CLOSED”–holdventilationoperation:

1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
11
www.QuestProtect.com
quest
quest
1.Pressthe“VENT”button.Thecurrentsettingwillbegintoashonthedisplay.Releasethebutton.
2.Pressthe“VENT”buttonagaintoswitchbetween“OPEN”and“CLOSED”.
3.Leavethecontrolalonefor10secondsandyoursettingswillbesaved.
Damper Operation and Ventilation, Programmed Ventilation
Thisexampleshowsthesysteminprogrammode(denotedbytheschedule15minuteson,5minutesoffandthe
wordRUNinthelowerrightcornerofthedisplay).
TheQuestDEH3000willoperatefreshairventilationaccordingtoyour
ventilationprogram.Thecontrolneedstobeprogrammedtoturnthe
ventilationfunctionONandOFFatthedesiredintervals.Thisisdoneby
programmingtheventilationtimer.
Therearetwoprogramsavailableforventilation:
1.MondaythroughSunday
2.MondaythroughFriday&Saturday/Sunday
Eachblockofdayshasamorningscheduleandanightschedule.Morningis
therst12hoursofthedayandnightisthesecond12hours.
Eachschedulehas:
•A“START”timewhentheventilationschedulebegins,
•An“OPEN FOR”durationfortheamountoftimethedamperstaysopenin5minuteintervals,from0to60,
•And“CLOSED FOR”durationwhichclosesthedamperforaspeciedtimein5minuteintervalsfrom0to60.
Setting the Ventilation Program:
1.Pressthe“PROGRAM ENTER”buttonuntilthefollowingmenu
appears:
2.Usingtheup/down“RH”buttons,highlight“PROGRAM”andselect
itbypressingthe“PROGRAM ENTER”button.Thefollowingmenu
appears:

quest
quest 1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
12
www.QuestProtect.com
Youcanselectfrom:
“MON-FRI”“SAT-SUN”forseparateweekdayandweekendschedules,or“MON-SUN”whichgivesyouequal
weekdayandweekendschedules.
3.UsingtheUp/Down“RH”buttons,highlightandthenselectoneofthetwochoices.Theexamplegivenshows
howtoprogramseparateweekdayandweekendschedules.Thesamemethodisusedifyouchoosetheother
program.
Example:menuwhenyouselect“MON-FRI”“SAT-SUN”:
1.Enterthestartingtimeforweekdaysusingtheup/down“RH”buttonstochangethetime.
2.Pressthe“PROGRAM ENTER”buttontoswitchtothe“OPEN FOR”setting.Usingtheup/down“RH”buttons,
changethedurationthatthedamperwillventilatefreshair.
3.Pressthe“PROGRAMENTER”buttontoswitchtothe“CLOSEDFOR”setting.Usingtheup/down“RH”
buttons,changethedurationthatthedamperwillremainclosedbetweenventilationcycles.
Fortheexamplegiven,startingat8:00AMinthemorning,thecontrolwillventilatefreshairfor15minutesthen
stopfor15minutes.Thisscheduleof15minutesopen,15minutesclosedwillcontinueuntilthestarttimeofthe
nightschedule.
Morningscheduleisavailableanytimefrom12:00AMuntil11:59AM.
Nightscheduleisavailableanytimefrom12:00PMuntil11:59PM.
4.Press“PROGRAMENTER”againtogotothe“MON-FRI”nightschedule.Repeatthestepslistedaboveforthis
andthe“SAT-SUN”dayandnightschedules.
Whenyouhavenishedprogrammingyourschedule(eitherthe7-dayversionortheweekday/weekendsplit
version),usethedown“RH”buttontohighlighttheEXIToptionandthenpress“PROGRAM ENTER”toselectit.
RunningtheVentilationProgram
Pressandholdthe“PROGRAM ENTER”buttonuntilthe“PROGRAM”screenappears.
Usethedown“RH”buttontohighlight“RUN PROGRAM”:
Thenpress“PROGRAMENTER”toselectit.Thedisplaywillappearas
follows:

1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
13
www.QuestProtect.com
quest
quest
4.0 Temperature Cutout Programming
Dehumidiersproduceheatwhendehumidifyinganddependinguponoutsideconditions,theventilation
functionmayalsointroducewarmair.Someconditionsmayintroduceenoughheattodrivetemperaturesup.
TheQuestDEH3000temperaturecutoutfeaturedisablesallQuestoperationsiftemperaturesreachthecutout
setpoint.
Inmostinstallationsthisfeaturewillnotneedtobeused(thecutoutisfactorysetto99°F).Ifalowertemperature
cutoutisdesired,programthesetpointbypressingandholdingthe“PROGRAMENTER”buttonuntilthe
“PROGRAM”screenappears.Presstheup/down“RH”buttonsuntil“TEMPCUTOUT”highlighted.Thenpress
the“PROGRAMENTER”buttonagaintoselectit.Nowusethe“RH”upor“RH”downbuttonstoadjustthe
setpoint.Press“PROGRAMENTER”toreturntothehomescreen.

quest
quest 1-800-533-7533
Quest DEH 3000 Installation, Operation and Maintenance Instructions
14
www.QuestProtect.com
WARRANTOR:
Therma-StorLLC
POBox8680
Madison,WI53708
Telephone:1-800-533-7533
WHO IS COVERED: Thiswarrantyextendsonlytotheoriginalresidentialend-useroftheQuest
DEH3000Dehumidier&VentilationSystemController,andmaynotbeassignedortransferred.
FIRST YEAR WARRANTY: Therma-Stor LLC warrantsthat,for one (1)yeartheQuestDEH3000
Dehumidier&VentilationSystemControllerwilloperatefreefromanydefectsinmaterialsand
workmanship,orTherma-StorLLCwill,atitsoption,repairorreplacethedefectivepart(s),freeof
anycharge.
END-USER RESPONSIBILITIES:WarrantyservicemustbeperformedbyaServicerauthorizedby
Therma-StorLLC.Iftheend-userisunabletolocateorobtainwarrantyservicefromanauthorized
Servicer,heshouldcallTherma-StorLLCattheabovenumberand ask fortheTherma-StorLLC
ServiceDepartment,whichwillthenarrangeforcoveredwarrantyservice.Warrantyservicewillbe
performedduringnormalworkinghours.
TheEnd-usermustpresentproofofpurchase(lease)uponrequest,byuseofthewarrantycardor
otherreasonableandreliablemeans.Theend-userisresponsiblefornormalcare.Thiswarrantyonly
appliestoresidentialapplicationsanddoesnotcoveranydefect,malfunction,etc.resultingfrom
misuse,abuse,lackofnormalcare,corrosion,freezing,tampering,modication,unauthorizedor
improperrepairorinstallation,accident,actsofnatureoranyothercausebeyondTherma-StorLLC's
reasonablecontrol.
LIMITATIONS AND EXCLUSIONS: If any Quest DEH 3000 Dehumidier &Ventilation System
Controllerpartisrepairedorreplaced,thenewpartshallbewarrantedforonlytheremainderofthe
originalwarrantyperiodapplicablethereto(butallwarrantyperiodswillbeextendedbytheperiod
oftime,ifany,thattheQuestDEH3000Dehumidier&VentilationSystemControllerisoutof
servicewhileawaitingcoveredwarrantyservice).
UPONTHEEXPIRATIONOFTHEWRITTENWARRANTYAPPLICABLETOTHEQuestDEH3000
Dehumidier&VentilationSystemControllerORANYPARTTHEREOF,ALLOTHERWARRANTIES
IMPLIEDBYLAW,INCLUDINGMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE,
SHALLALSOEXPIRE.ALLWARRANTIESMADEBYTHERMA-STORLLCARESETFORTHHEREIN,
ANDNOCLAIMMAYBEMADEAGAINSTTHERMA-STORLLCBASEDONANYORALWARRANTY.
INNOEVENTSHALLTHERMA-STORLLC,INCONNECTIONWITHTHESALE,INSTALLATION,USE,
REPAIRORREPLACEMENTOFANYQuestDEH3000Dehumidier&VentilationSystemController
ORPARTTHEREOFBELIABLEUNDERANYLEGALTHEORYFORANYSPECIAL,INDIRECTOR
CONSEQUENTIALDAMAGESINCLUDINGWITHOUTLIMITATIONWATERDAMAGE(THEEND-
USERSHOULDTAKEPRECAUTIONSAGAINSTSAME),LOSTPROFITS,DELAY,ORLOSSOFUSE
ORDAMAGETOANYREALORPERSONALPROPERTY.
Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,andsomedonotallow
theexclusionorlimitationofincidentalorconsequentialdamages,sooneorbothoftheselimitation
maynotapplytoyou.
LEGAL RIGHTS: Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrights
whichvaryfromstatetostate.
Table of contents
Other Quest Engineering Control Panel manuals