Radiant DIAGNOCODE SM 20015 User manual

CE 0694 TA02E002.B1103
Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH
Setting Instruction Manual
for boilers with
DIAGNOCODE SM 20015
Printed Circuit Board
mod.
RSF 30 E
RMA 24 E xRMAS 20 E xRMAS 24 E xRMAS 30 E
RMA 21 E NOx xRMAS 21 E/3S
RBA 24 E xRBA 35 E xRBA 100 E
RBA CS 24 E xRBA CS 30 xRBA CS 100 E xRBA CS 30/100
RMAS 20 E/Plusbox xRMAS 24 E/Maxibox xRMAS 30 E/Superbox


P.C.B. SM 20015 –boiler settings
INDEX
CONTROL PANEL page 1
DIAGNOCODE SM 20015 ELECTRONIC PRINTED CIRCUIT BOARD: page 2
ERROR CODES page 3
FUNCTIONS CODES page 3
PARAMETERS TABLE page 4
Parameters Setting procedure No. 1 page 5
2 page 5
3 page 6
4 page 6
5 page 7
6 page 7
7 page 8
8 page 8
9 page 9
10 page 9
11 page 10-11
GAS PRESSURE DIAGRAMS page 12-13
ELECTRICAL WIRING DIAGRAMS page 14-16

P.C.B. SM 20015 –boiler settings 1
CONTROL PANEL
1
ON / OFF POWER BUTTON
2
HEATING TEMPERATURE ADJUSTMENT KNOB
3
DOMESTIC HOT WATER TEMPERATURE ADJUSTMENT
KNOB
6
MODE SELECTION PAD (SUMMER ONLY / WINTER ONLY
/ SUMMER AND WINTER)
5
CHIMNEY-SWEEPER SELECTION PAD / PARAMETER
SETTING SERVICE PAD
4
OUTSIDE TEMPERATURE DISPLAY PAD (ONLY WITH
OPTIONAL OUTSIDE TEMPERATURE SENSOR FITTED)
14
TEMPERATURE AND ERROR CODES DISPLAY
13
WATER DEFICIENCY INDICATOR
12
WATER PRESSURE LEVEL 1 BAR INDICATOR
11
WATER PRESSURE LEVEL 1.5 BAR INDICATOR
10
GENERAL LOCK-OUT WITH FLASHING ERROR CODE ON
DISPLAY
9
HEATING MODE (STABLE LIGHT)
HEATING OPERATION (FLASHING LIGHT)
8
DOMESTIC HOT WATER MODE (STABLE LIGHT);
DOMESTIC HOT WATER OPERATION (FLASHING LIGHT).

P.C.B. SM 20015 –boiler settings
2
DIAGNOCODE SM 20015 ELECTRONIC PRINTED CIRCUIT BOARD
cod. 76655LA
M3
M5
M6
M7
M11
M13
M2
M4
M1
M12
M10
M8
M9
TECHNICAL SPECIFICATION
New generation printed circuit board with easy settings of boiler parameters.
Special features: :
Exclusively for technicians settings
•Standard / reduced heating temperature
•Water-Hammer prevention function
•Short cycling function-3 minutes, heating circuit
•Pump overrun function - heating circuit
•Pump overrun function - dom. hot water circuit
•Minimum output setting
•Maximum heating output setting
User settings
•On / Off operation
•Heating temperature adjustment from 30 to 80 °C
•Domestic Hot Water adjustment from 35 to 65 °C
•Mode Selection: summer only / winter only /
summer and winter
•Lock-out
•Normal water pressure
•Water deficiency safety switch
•Temperature display

P.C.B. SM 20015 –boiler settings
3
ERROR CODES:
IONISATION LOCK-OUT
HIGH LIMIT THERMOSTAT LOCK-OUT
FLUE SAFETY THERMOSTAT LOCK-OUT (FOR OPEN CHAMBER MODELS ONLY)
WATER PRESSURE SWITCH LOCK-OUT
HEATING SENSOR FAILURE
DOMESTIC HOT WATER SENSOR FAILURE
STORAGE TANK WATER SENSOR FAILURE
AIR PRESSURE SWITCH LOCK-OUT
REQUEST OF PARAMETERS RE-SETTING
FUNCTIONS CODES
CODE TYPE OF FUNCTION DESCRIPTION
CHIMNEY-SWEEPER
FUNCTION ON
THE CHIMNEY-SWEEPER FUNCTION IS ACTIVATED BY KEEPING PRESSED
"SERVICE" PAD FOR 5 SECONDS. TO CANCEL IT RESET THE UNIT BY
PUSHING ON/OFF BUTTON.
THIS FUNCTION BRINGS THE UNIT TO THE MAX HEATING GAS PRESSURE
FOR 15 MINUTES WITHOUT MODULATING DOWN. IT IS USEFUL WHILE
CARRYING ON THE COMBUSTION TEST.
ANTI-FROST FUNCTION
HEATING CIRCUIT
THIS FUNCTION COMES INTO OPERATION WHEN THE HEATING SENSOR
SENSES A 5°C TEMPERATURE. THE BOILER STARTS AT THE MINIMUM GAS
PRESSURE, WITH THE 3-WAY VALVE IN WINTER POSITION. THE BOILER
STOPS WHEN THE TEMPERATURE TAKEN BY THE SENSOR HAS REACHED
30°C .
ANTI-FROST FUNCTION
DOMESTIC HOT WATER
CIRCUIT
THIS FUNCTION COMES INTO OPERATION WHEN THE HOT WATER SENSOR
SENSES A 4 °C TEMPERATURE. THE BOILER STARTS AT THE MINIMUM GAS
PRESSURE, WITH THE 3-WAY VALVE IN SUMMER POSITION AND HEATS THE
HOT WATER CIRCUIT. THE BOILER STOPS WHEN THE TEMPERATURE TAKEN
BY THE HOT WATER SENSOR HAS REACHED 8°C .
ANTI-FROST FUNCTION
D.H.W. CIRCUIT - STORAGE
BOILERS.
SAME OPERATION AS THE ANTI-FROST FUNCTION OF D.H.W. CIRCUIT FOR
INSTANTANEOUS BOILERS.
LEGIONELLA PREVENTION
FUNCTION.
FUNCTION ACTIVE FOR STORAGE BOILERS ONLY. IT COMES INTO
OPERATION EVERY 7 DAYS .
IT BRINGS THE HOT WATER TEMPERATURE OF THE STORAGE CYLINDER UP
TO 60°C WHATEVER TEMPERATURE VALUE IS SET FOR HOT WATER.
NOT COMPATIBLE
REMOTE CONTROL.
THIS CODE IS DISPLAYED WHEN THE REMOTE CONTROL OR OUTSIDE
TEMPERATURE SENSOR CONNECTED ARE NOT ORIGINAL RADIANT PARTS.
1
2
3
4
5
1
2
1
4
22
6
7
8
9
1
3
28
31

P.C.B. SM 20015 –boiler settings
4
PARAMETERS TABLE
PARAMETER
NUMBER TYPE OF OPERATION PARAMETER
VALUE FUNCTION
page
0 BOILER TYPE SELECTION 00
01
WALL MOUNTED OR FLOOR STANDING
OIL FLOOR STANDING UNIT
1 BOILER TYPE SELECTION
00
01
02
INSTANTANEOUS
WITH STORAGE CYLINDER
WITH STORAGE CYLINDER-COMFORT
(+ 7°C)
3
2 GAS TYPE SELECTION 00
01
NATURAL GAS
L.P.G. 4
3 HEATING TEMPERATURE
SETTING
00
01
STANDARD: from 30 to 80°C
REDUCED : from 25 to 40°C 5
4 PUMP SETTING IN HEATING
MODE
00
01
STANDARD (PUMP OVERRUN 3”)
PERMANENT (PUMP ON ALL THE TIME) 6
5 WATER-HAMMER PREVENTION
SETTING
00
01
EXCLUDED
ACTIVE (2” STANDBY) 7
6
SHORT CYCLING FUNCTION -
HEATING CIRCUIT
(FACTORY CALIBRATED AT 180” -
PARAMETER VALUE “36” )
00 - 90 EXPRESSED IN STEPS OF 5 SEC.
Ex. 90 x 5 = 450“ (7.5 MIN.) 8
7
PUMP OVERRUN -
HEATING CIRCUIT
(FACTORY CALIBRATED AT 180”-
PARAMETER VALUE “36” )
00 - 90 EXPRESSED IN STEPS OF 5 SEC.
Ex. 90 X 5 = 450“ (7.5 MIN.) 9
8
PUMP OVERRUN
DOM. HOT WATER CIRCUIT
(FACTORY CALIBRATED AT 90”)
00 - 90 EXPRESSED IN STEPS OF 5 SEC.
Ex. 90 X 5 = 450“ (7.5 MIN.) 10
9 MIN. GAS MODULATION SETTING 0 – 50% FACTORY CALIBRATED (Mechanical
minimum) -
10 MINIMUM HEATING OUTPUT
SETTING 0 – 50% FACTORY CALIBRATED -
11
MAXIMUM GAS PRESSURE
SETTING - MAXIMUM HEATING
OUTPUT SETTING
MAX GAS - 99 11
Parameter cancelled starting from June 2003
9

P.C.B. SM 20015 –boiler settings
5
Parameter 1setting: BOILER TYPE SELECTION
To modify the Parameter value:
a. Put ON/OFF button 1in OFF position ( );
b. Push pad 6and simultaneously and keep them pressed;
c. Put ON/OFF button 1in ON position () and wait until the display shows - ;
d. Release pad 6and ;
e. Keeping pad 5pressed, press pad 6and select parameter no. ;
f. Release service pad 5; press and release service pad 5;
g. The display will show the parameter value to be set or modified;
h. Press pad 6or to modify (increase or decrease) the parameter value instantaneous type, storage type or storage
type comfort;
i. Press and release service pad 5to confirm setting;
j. The display will show parameter no. ;
k. Position ON/OFF button 1first in OFF position ( ) and back to ON position ( );
Parameter 2setting: GAS TYPE SELECTION
To modify the Parameter value:
a. Put ON/OFF button 1in OFF position ( );
b. Push pad 6and simultaneously and keep them pressed;
c. Put ON/OFF button 1in ON position () and wait until the display shows - ;
d. Release pad 6and ;
e. Keeping pad pressed, press pad 6and select parameter no ;
f. Release service pad 5; press and release pad service ;
g. The display will show the parameter value to be set or modified;
h. Press pad 6or to modify (increase or decrease) the parameter value NATURAL GAS, L.P.G ;
i. Press and release service pad to confirm setting;
j. The display will show parameter no. ;
k. Position ON / OFF button 1first in OFF position ( ) and back to ON position ( );
P
L
0
00
01
02
1
00
01
2
2
1
P
l
0

P.C.B. SM 20015 –boiler settings
6
Parameter 3setting: HEATING TEMPERATURE SETTING
To modify the Parameter value:
a. Put ON/OFF button 1in OFF position ( );
b. Push pad 6and simultaneously and keep them pressed;
c. Put ON/OFF button 1in ON position ( )and wait until the display shows - ;
d. Release pad 6and ;
e. Keeping pad 5pressed, press pad 6and select parameter no. ;
f. Release service pad 5; press and release service pad 5;
g. The display will show the parameter value to be set or modified;
h. Press pad 6or to modify (increase or decrease) the parameter value STANDARD from 30 to 80°C, REDUCED from 25 to
40°C ;
i. Press and release service pad 5to confirm setting;
j. The display will show parameter no. ;
k. Position ON/OFF button 1first in OFF position ( ) and back to ON position ( );
Parameter “4” setting: PUMP SETTING IN HEATING MODE
To modify the Parameter value:
a. Put ON/OFF button 1in OFF position ( );
b. Push pad 6and simultaneously and keep them pressed;
c. Put ON/OFF button 1in ON position () and wait until the display shows - ;
d. Release pad 6and ;
e. Keeping pad pressed, press pad 6and select parameter no. ;
f. Release service pad ; press and release service pad ;
g. The display will show the parameter value to be set or modified;
h. Press pad 6or to modify (increase or decrease) the parameter value STANDARD (pump overrun), PERMANENT (pump
ON all the time);
i. Press and release service pad to confirm setting;
j. The display will show parameter no. ;
k. Position ON/OFF button 1first in OFF position ( ) and back to ON position ( );
P
L
0
00
01
3
3
P
L
0
00
01
4
4

P.C.B. SM 20015 –boiler settings
7
Parameter 5setting: WATER-HAMMER PREVENTION SETTING
To modify the Parameter value:
a. Put ON/OFF button 1in OFF position ( );
b. Push pad 6and simultaneously and keep them pressed;
c. Put ON/OFF button 1in ON position () and wait until the display shows - ;
d. Release pad 6and ;
e. Keeping pad pressed, press pad 6and select parameter no. ;
f. Release service pad ; press and release service pad ;
g. The display will show the parameter value to be set or modified;
h. Press pad 6or to modify (increase or decrease) the parameter value EXCLUDED, ACTIVE – 2 sec. Stand by;
i. Press and release service pad to confirm setting;
j. The display will show parameter no ;
k. Position ON/OFF button 1first in OFF position ( ) and back to ON position ();
Parameter 6setting: SHORT CYCLING FUNCTION - HEATING CIRCUIT - adjustable from 0 to 7.5 minutes
Factory calibrated at 3 minutes STANDBY
To modify the Parameter value:
a. Put ON/OFF button 1in OFF position ( );
b. Push pad 6and simultaneously and keep them pressed;
c. Put ON/OFF button 1in ON position () and wait until the display shows - ;
d. Release pad 6and ;
e. Keeping pad pressed, press pad 6and select parameter no. ;
f. Release service pad ; press and release service pad ;
g. The display will show the parameter value to be set or modified;
h. Press pad 6or to modify (increase or decrease) the parameter value from to (factory calibrated = 3 minutes);
i. Press and release service pad to confirm setting;
j. The display will show parameter no. ;
k. Position ON/OFF button 1first in OFF position ( ) and back to ON position ( );
P
L
0
00
01
5
5
P
L
0
00
90
6
6
36

P.C.B. SM 20015 –boiler settings
8
Parameter 7setting: PUMP OVERRUN - HEATING CIRCUIT adjustable from 0 to 7.5 minutes.
Factory calibrated at 3 minutes STANDBY.
(N.B. DO NOT set the overrun time under 3 minutes)
To modify the Parameter value:
a. Put ON/OFF button 1in OFF position ( );
b. Push pad 6and simultaneously and keep them pressed;
c. Put ON/OFF button 1in ON position () and wait until the display shows - ;
d. Release pad 6and ;
e. Keeping pad pressed, press pad 6and select parameter no ;
f. Release service pad ; press and release service pad ;
g. The display will show the parameter value to be set or modified;
h. Press pad 6or to modify (increase or decrease) the parameter value from to (factory calibrated = to 3 minutes);
i. Press and release service pad to confirm setting;
j. The display will show parameter no. ;
k. Position ON/OFF button 1first in OFF position ( ) and back to ON position ( );
Parametr 8setting: PUMP OVERRUN - DOMESTIC HOT WATER CIRCUIT adjustable from 0 to 7.5 minutes.
Factory calibrated at 1.30 minutes STANDBY.
(N.B. DO NOT set the overrun time under 1.30 minutes)
To modify the Parameter value:
a. Put ON/OFF button 1in OFF position ( );
b. Push pad 6and simultaneously and keep them pressed;
c. Put ON/OFF button 1in ON position () and wait until the display shows - ;
d. Release pad 6and ;
e. Keeping pad pressed, press pad 6and select parameter no. ;
f. Release service pad ; press and release service pad ;
g. The display will show the parameter value to be set or modified;
l. Press pad 6or to modify (increase or decrease) the parameter value from to (factory calibrated = to 90 seconds;
h. Press and release service pad to confirm setting;
i. The display will show parameter no. ;
j. Position ON/OFF button 1first in OFF position ( ) and back to ON position ( );
P
L
0
00
90
7
7
P
L
0
00
90
8
8
36
1
8

P.C.B. SM 20015 –boiler settings
9
D
10
20
30
40
MANOMETRO
9: Mechanical minimum gas pressure setting
The mechanical minimum gas pressure is factory calibrated on all boilers at 17/18 mmH20.
When replacing the gas valve adjust the mechanical minimum pressure as follows: :
•Using a single cut screwdriver turn Dscrew (fig.1 ) clockwise and tight it ;
•To adjust the mechanical minimum, turn Dscrew (fig.1) counter-clockwise for
two complete turns.
Parameter 10 setting: MINIMUM HEATING OUTPUT SETTING
To check or modify the existing pressure value:
a. insert a manometer into the gas valve pressure point B(fig.1);
b. Put ON / OFF button 1in OFF position ( );
c. Push pad 6and simultaneously and keep them pressed;
d. Put ON / OFF button 1in ON position ( ) and wait until the display shows - ;
e. Release pad 6and ;
f. Keeping pad pressed, press pad 6and select parameter no. ;
g. Release service pad , press and release service pad ;
h. The display will show the parameter value to be set or modified;
i. The manometer inserted in the pressure point B(fig. 1) will show the minimum gas pressure;
j. If that value is different than the one stated on the data plate, modify it by pressing pad 6to increase or pad to decrease gas pressure ;
k. Once the minimum gas pressure has been adjusted, switch the boiler OFF by putting ON / OFF button 1in OFF position ( );
l. Remove the silicon pipe from the pressure point B(fig.1), close tightly the pressure point screw and make sure there are no gas leaks;
m. Position the ON / OFF button 1in ON position ( );
Gas valve VK 4105G
P
L
0
1
0
Fig. 1

P.C.B. SM 20015 –boiler settings
10
D
B
10
20
30
40
A
MANOMETRO
C
Parameter 11 setting: MAXIMUM GAS PRESSURE SETTING - MAXIMUM HEATING OUTPUT SETTING
To check or modify the existing pressure value:
a. Insert a manometer into the gas valve pressure point B(fig.1);
b. Put ON / OFF button 1in OFF position ( );
c. Push pad 6and simultaneously and keep them pressed;
d. Put ON / OFF button 1in ON position () and wait until the
display shows - ;
e. Release pad 6and ;
f. Keeping pad pressed, press pad 6and select parameter no. ;
g. Release service pad , press and release service pad ;
h. The display will show the parameter value to be set or modified;
i. Press pad 6to reach value on display;
j. Once the parameter value “99” has been reached, press and release service pad the display will show value ;
k. Position ON/OFF button 1in OFF position ( ) and back to ON position ( );
l. Open the hot water tap at the maximum flow and temperature to switch the boiler ON;
m. The manometer inserted in the pressure point B (fig. 1) will show the maximum gas pressure
n. If that value is different than the one stated in the data plate (see Gas Pressure adjustment table) modify it as follows:
o. Remove the aluminium cap A(fig.1) and, with a screwdriver, turn the plastic screw;
p. Turn clockwise to increase gas pressure and counter clockwise to decrease gas pressure;
q. Once the maximum gas pressure has been adjusted screw aluminium cap A back to position onto the gas valve;
r. Switch the boiler OFF by putting ON/OFF button 1in OFF position ( );
s. Remove the silicon pipe from the pressure point B(fig.1), close tightly the pressure point screw and make sure there are no gas leaks.
99
1
1
P
L
0
1
1
Gas valve VK 4105G
Fig. 1

P.C.B. SM 20015 –boiler settings
11
D
B
10
20
30
40
A
MANOMETRO
C
Parameter 11 setting: MAXIMUM HEATING OUTPUT SETTING
To check or modify the existing pressure value:
a. Insert a manometer into the gas valve pressure point B(fig.1);
b. Put ON/OFF button1in OFF position ( );
c. Push pad 6and simultaneously and keep them pressed;
d. Put ON/OFF button 1in ON position ( ) and wait until the display shows
- ;
e. Release pad 6and ;
f. Keeping service pad pressed, press pad 6and select parameter no. ;
g. Release service pad press and release service pad ;
h. The display will show the parameter value to be set or modified;
i. Press pad 6to increase or pad to decrease gas pressure according to heating system kW (output) requirement as per table 1 (the gas
pressure value will be displayed in the manometer);
j. Once the required pressure has been reached, press and release service pad , the display ill show value ;
t. Position the ON/OFF button 1in OFF position ( )
k. Remove the silicon pipe from the pressure point B(fig.1), close tigly the pressure point screw and make sure there are no gas leaks;
l. Put the ON/OF button in ON position ( );
Gas valve VK 4105G
Fig. 1
P
L
0
1
1
1
1

P.C.B. SM 20015 –boiler settings
12
MAXIMUM HEATING OUTPUT GAS PRESSURE DIAGRAMS
For 24 kW output boilers
(G20 - G30/31)
LPG
NATURAL GAS
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
0123456789101112131415161718192021222324252627282930313233
Gas pressure in mbar
Output capacity in kW
For 27 kW output boilers
(G20 - G30/31)
L,P,G,
NATURAL GAS
0
5
10
15
20
25
30
35
0246810121416182022242628303234
Gas pressure in mbar
Output capacity in kW
For 32 kW output boilers
(G20 - G30/31)
L.P.G.
NATURAL GAS
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
Gas Pressure in mbar
Output capacity in kw
mod.
RMAS 20 E
RMAS 20 E /Plusbox
mod.
RMA 24 E
RMAS 24 E
RBA 24 E
RBA CS 24 E
RBA 100 E
RBA CS 100 E
RMAS 24 E / Maxibox
mod.
RMAS 30 E
RBA CS 30
RBA CS 30/100
RMAS 30 / Superbox

P.C.B. SM 20015 –boiler settings
13
MAXIMUM HEATING OUTPUT GAS PRESSURE DIAGRAM
For 32 kW output boilers
(G20 - G30/31)
METANO
G.P.L.
14
16
18
20
22
24
26
28
30
32
34
36
0123456789101112131415161718192021222324252627282930313233
Pressione gas in mbar
Portata termica in kW
For 23 kW output boilers
(G20 - G30/31)
GPL
METANO
NATURAL GAS L.P.G.
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
0 2 4 6 8 101214161820222426
Gas burner pressure in mbar
Output capacity in kW
mod.
RMA 21 E NOx
RMAS 21 E/3S
mod.
RBA 35 E

P.C.B. SM 20015 –boiler settings
14
WIRING DIAGRAMS – OPEN COMBUSTION CHAMBER BOILERS
PRINTED CIRCUIT BOARD CVI-M SM20015 (cod. 76655LA)
R
22
M4
M4
1918 2120
C
brown
light-blue
light-blue
black
SC
brown
VD
red
electric connection with
MATER XP300 water
pressure switch
50
black
black
black
black
white
4645 47 4948
SRSS MF
brown
M8
brown
5755 56 58 59
black
black
brown
60 61
M9
light-blue
light-blue
PWM
1,5bar
1bar +
M3
-
M5
M6
M7
M11
M13
+- - 3-WAY DIVERTER VALVE
- IGNITION ELECTRODE
- IONISATION ELECTRODE
M2
M5
567 98
M1
123 4
brown
light-blue
IG
black
black
17
1
-
PWM
12
light-blue
10 11
grey
black
RS
light-blue
brown
13 14 1615
L
12 11 910 8
+
76 543 2
N
56
1bar
PAC
brown
black
M3
55
brown
brown
light-blue
black
5957 58 60 61
TF
+-
PWM
CONNECTOR FOR
SM6545QM 1012
EA
ER
VD
black
black
M10
5251 53 54
Optional
TERMINAL
BLOCK
M9
L
50 Hz
N
230V
TA
SE
DISPLAY DIGITAL BOARD 2000 SKO6206
(COD. 76654LA)
- FLUE SAFETY THERMOSTAT
- MAIN SWITCH
- WATER PRESSURE SWITCH
- ELECTRONIC FLOWSWITCH
- D.H. WATER SENSOR
- CIRCULATION PUMP
- HEATING SENSOR
- ROOM THERMOSTAT
- OUTDOOR SENSOR TEMPERATURE
- SAFETY THERMOSTAT
ELECTRONIC IGNITION BOARD
CVI S4565 A 2019B (COD. 76631LA)
M1
1
11
12
LM
910 8 476 5 3 2
M2
SE
SR
MF
IG
SS
PAC
TA
TS
TF-RS
C
N- NEUTRAL
KEY
L- LINE
M9
M12
M8
M10

P.C.B. SM 20015 –boiler settings
15
WIRING DIAGRAMS - ROOM SEALED BOILERS
PRINTED CIRCUIT BOARD CVI-M SM20015 (cod. 76655LA)
R
22
M4
M4
1918 2120
C
brown
light-blue
light-blue
black
SC
brown
VD
red
electric connection with
MATER XP300 water
pressure switch
50
black
black
black
black
white
4645 47 4948
SRSS MF
brown
M8
brown
5755 56 58 59
black
black
brown
60 61
M9
light-blue
light-blue
PWM
1,5bar
1bar +
M3
-
M5
M6
M7
M11
M13
- 3-WAY DIVERTER VALVE
+-
- IONISATION ELECTRODE
- IGNITION ELECTRODE
M2
M5
567 98
black
C
light-blue
brown
EV
NO
PA
NC
M1
123 4
brown
light-blue
IG
black
black
17
1
PWM
12
light-blue
10 11
grey
black
RS
light-blue
brown
13 14 1615
L
12 11 910 8
+
76 543 2
N
56
1bar
PAC
brown
black
M3
55
brown
brown
light-blue
black
5957 58 60 61
+-
PWM
CONNECTOR FOR
SM6545QM 1012
EA
ER
EV
VD
-
- FAN
black
black
M10
5251 53 54
Optional
TERMINAL
BLOCK
M9
L
50 Hz
N
230V
TA
SE
DISPLAY DIGITAL BOARD 2000 SKO6206
(COD. 76654LA)
- SAFETY THERMOSTAT
- OUTDOOR SENSOR TEMPERATURE
- ROOM THERMOSTAT
- HEATING SENSOR
- CIRCULATION PUMP
- AIR PRESSURE SWITCH
- D.H. WATER SENSOR
- ELECTRONIC FLOWSWITCH
- WATER PRESSURE SWITCH
- MAIN SWITCH
ELECTRONIC IGNITION BOARD
CVI S4565 A 2019B (COD. 76631LA)
M1
1
11
12
LM
910 8 476 5 3 2
M2
SE
SR
MF
IG
SS
PA
PAC
TA
TS
C
N- NEUTRAL
KEY
L- LINE
M9
M12
M8
M10

P.C.B. SM 20015 –boiler settings
16
WIRING DIAGRAM FOR REMOTE CONTROL INSTALLATION (no zone valves)
Fit the interface (fig. 2) on the circuit board (fig. 1) into the holes A and B provided (see fig. 1).
Connect plug M1 on the interface circuit board (fig. 2) to plug M11 on the modulation circuit board (fig. 1).
Connect the grey and orange wires in plug M2 of the interface circuit board (fig. 2) and in the terminal block (fig.
4).
Connect the wires of plug M3 on the interface circuit board (fig. 2) in the terminal (fig. 4).
Remove the link TA-TA (fig. 3) and set the boiler to SUMMER mode.
Connect the remote control to the terminal block (fig. 4) using a cable with a minimum section of 2 x 0.5 mm2
section and max. length of 50 m being careful to observe the +/- polarity.
THE EXTERNAL SENSOR IS OPTIONAL. The connection can be made to either the remote control (fig. 5) or to
the terminal block (fig. 3 - dotted line) on the terminals marked SE-SE.
WARNING! The remote control connection cable must pass through a channel which is separate from any system
supplied with power. If this is not possible, fit a screened cable.
M6
M4
M3
M5
M2 M1
M4
M13
M7
M11
M8
M12
M10 M9
EXTERNAL SENSOR
2M1
1
TELS EXT IN
-
+
REMOTO
N
LSe
TA TA
Se
LINE
Fig. 3
EARTH
NEUTRAL
EXTERNAL
SENSOR
ROOM
THERMOSTAT
5+VZ
Fig. 4
4-
RL1
orange
grey
M3
M2
7 8
Fig. 2
M1
Interfaccia
13
EXTERNAL SENSOR
FLOW TEMPERATURE CORRECTION LAW HOW IN THE RELATION TO THE EXTERNAL
TEMPERATURE AND POSITION OF THE USER HEATING TEMP. ADJUSTMENT.
TM - MAX / MIN = Range of flow temperature selected
70
35
MIN
25
27 26
30
30
35
45
40
50
60
55
65
192425 23 2122 20 1618 17 15 14
Tm
MAX
40 80
75
Te = External temperature Tm = flow temperature
-121012 11 8975
64231 -6-3-10-2
-4 -5 -9
-7 -8 -10 -11
8
9765
0
Te (°C)
-15-13 -14
1
2
3
4
Fig. 1
Fig. 5
P.B.C.
INTERFACE
REMOTE
AB

RADIANT BRUCIATORI s.p.a.
Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU)
Tel. +39 0721 9079.1 • fax. +39 0721 9079279
e-mail: tecnico@radiant • Internet: http://www.radiant.it
ALL DESCRIPTIONS AND ILLUSTRATIONS CONTAINED IN THIS LEAFLET HAVE
BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES
AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE
ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET. E + OE
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED,
SAVED IN STORAGE SYSTEMS OR TRANSMITTED IN ANY FORM OR BY ANY
MEANS, WHETHER ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING
OR OTHERS, WITHOUT THE MANUFACTURER'S PRIOR AUTHORISATION IN
WRITING.
TA01E002.B1103
Table of contents
Popular Computer Hardware manuals by other brands

BOSSCO
BOSSCO GT-1000 owner's manual

Corsair
Corsair 280X installation guide

Ublox
Ublox EVK-NINA-W13 user guide

ARTESYN EMBEDDED TECHNOLOGIES
ARTESYN EMBEDDED TECHNOLOGIES SharpMedia PCIE-8120 Assembly, Installation and Use

Sferalabs
Sferalabs SCMB30X Quick reference guide

Ublox
Ublox JODY-W1 Series System integration manual