Raindrip Wireless WeatherSmart Sensor
Page 2 of 2 RS INSTG-A
20091108
CONTROLLER INSTRUCTIONS:
This section provides specific instructions for WeatherSmart Controllers that utilize a WeaterSmart Sensor. Use the
Controller Installation & Programming guide for Controller installation, setup, programming instructions, and general
operating instructions.
Sensor Status Indicators:
•“SENSOR” is shown in the Controller display when the Sensor is detected by the Controller.
•“LOW BATTERY IN SENSOR” is shown in the Controller display when the batteries are low.
oReplace batteries. (see INSTALLATION section)
•“ERROR CHECK SENSOR” is shown in the Controller display when the Sensor signal is not detected by the
Controller
oCheck the Sensor for any obvious abnormalities or obstructions.
oInstall fresh batteries and reestablish communication between the Sensor and the Controller. (see
INSTALLATION section)
Rainfall Information:
•The amount of rainfall in inches is shown in the lower left corner of the Controller display
oToday’s Rainfall (resets at midnight each day)
oYTD Rainfall (resets at midnight on December 31)
Temperature Information:
•Outside Temperature is shown at the bottom center of the Controller display
•“LO” is displayed when the temperature is below 10º F
•“HI” is displayed when the temperature is above 150º F
Controller will temporarily disable watering schedules during the following conditions:
•When the outside temperature reaches 40º F or lower:
o“SHUTDOWN LOW TEMPERATURE” will be shown in the lower right corner of the Controller display.
oController normal watering operation will resume above 40º F.
•When rain is detected:
o“SHUTDOWN RAIN DETECTED” will be shown in the lower left corner of the Controller display.
o“REMAINING DURATION” of the rain shutdown will be shown in the upper right corner of the
Controller display.
oPress “EDIT SCHEDULE” to increase or decrease remaining duration.
oController normal watering operation will resume when remaining duration countdown is complete.
SPECIFICATIONS:
Batteries:
•Two (2) “AA” alkaline (not included)
•Depending on installed environment, batteries should be replaced once a year.
FCC STATEMENT:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any interference received, including interference that
may cause undesired operation.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this
equipment. Such modifications could void the user's authority to operate the equipment.
TECHNICAL SUPPORT::
•Phone: (877) 502-7952
oMonday – Friday 8:00 AM – 5:00 PM (Pacific Standard Time)
oSaturday – Sunday 9:00 AM – 1:00 PM (Pacific Standard Time)
•Email: techservice@ndspro.com