
LB9106
Hot Surface
!
Do Not Touch
Heat Sink or Lights
0-150 ft (0-50m) AWG 14 (2.50 mm)
>150 ft (> 50m) AWG 12 (4.00 mm)
• Electricalshockhazard.Donot
open enclosures.
•DO NOT START with signs of
visible damage.
•Blower is not intended for
operationinexplosiveatmospheres.
•Wear ear protection when close by.
•Keep body parts and loose objects
away from intake of fan.
• Donotmovewhilerunning.
• Operateandrepairbytrained
personnel only.
•Always use grounded plug and
properly ground AC power
receptacle.
•Heat sink becomes hot during
operationandcharging.LED
lights become hot during use.
Donottouch.
•Use with approved, good condition
extensioncordwithground
connector.
READ MANUAL BEFORE STARTING FOR THE FIRST TIME!
Thank you for purchasing the RAMFAN®EX50Li battery powered multi-purpose
ventilator manufactured in the USA by Euramco Safety, Inc.
For more than 30 years Euramco Safety has been on the cutting edge of
industrial,re,andmarineventilationproducts.Eachofourblower/exhausters,
smokeejectors,PPV&LSVfansandaccessoriesrepresentthenesttechnologies
available.Everyproductisconstructedtodemandingandexactspecicationsfor
quality, performance, and reliability.
When human life depends on having a fan that can deliver clean, safe air, you
have only one choice you can trust: RAMFAN.
Exploreourwebsiteandonlinecatalogatwww.euramco.com and discover how
RAMFANcanmakeadierenceintheeld!
All product information in the publication is based on the most current
information available at the time of printing. Euramco Safety, Inc. reserves the
right to make changes at anytime without notice.
PRIOR TO FIRST USE
1. OperateonACvoltage,85-264V,50/60Hz1Φ,forcharginganddischarging.
2. The unit is suitable for use on Ground Fault protected circuits.
3. Should the provided AC connector be unsuitable, replace with desired
connector containing a grounding circuit. Check continuity from ground
terminal to motor shell.
4. PlacebatteriesintoholdersandconnecttoIP66connectors,Fullycharge
priortorstuse.
5. This fan is for emergency service use. Charge fully between runs. Create a
charging protocol.
6. Tocharge,turnthespeedcontrolfullytotheleft(OFF)andthenconnect
toACoutlet.Indicatorlightswillilluminate,andthengoo.Whencharging
commences, indicator lights will show state of charge. Charging should
complete in 3-4 hours, with the indicator lights turning green.
7. ForDCoperationwithACdisconnected,holdthewakebuttonuntil
indicator lights come on showing battery state. Advance speed control.
8. For AC operation, advance speed control.
Warning Labels & Safety Precautions
Weight 45 lbs 20 kg
Dimensions 21x12x20.6in 534x304x523cm
Power AC Line(85-264V1Φ) 650w
Operating Temp
Range -4°F to 105°F/-20°C to 40°C
Charge Temp
Range 32°F to 105°F/0°C to 40°C
21"
12"
20.6"
2
1
4
3
Battery Wake button
LEDscenelight
BatteryIndicatorLights(L&R)
Speed Control
The EX50Li is a multi-purpose 18"/46cm ventilator powered by battery(s) or
85-264vsinglephaseAC.TheexibleframecongurationallowsforPPV,Smoke
Ejector or ducted blower use in both normal, horizontal and hanging positions.
Thefancanbetiltedfrom0-36°withintheframeinPPVmode.
Themotor,motorcontrollerandbatteriesarewater-resistant,IP66rated.
Themotorisavariable-speedBLDCmotorcontrolledbyamicroprocessor
integrated with
apowersupply,dualbatterychargersandanLEDlightdriver.
The EX50Li will run with one or two 40v 6Ah Li-ion battery packs. Each pack
yieldsabout23minofoperationatfullpower.Extendedoperationisachieved
by reducing speed. The batteries may be swapped during operation.
AC voltage can be applied while running on batteries and the ventilator will auto-
switch to AC power. Conversely, the AC power can be removed and the unit will
auto-switchtobatterypower,ifsucientchargeremains.
The integrated battery chargers will charge one or two fully discharged battery
packs in 4 hours or less.
LEDscenelightsareintegratedintothefanshroudandhaveahigh-low-o
switch.
Hold to change.
The integrated controller is EMI-protected to prevent interference with radio
communication.
AsimpleControlPanelonthetopofcontrollercontrolsallfunctions.
1.WhenACisdisconnectedandSpeedcontroliso,thecontrollerand
battery(s) will enter a sleep mode to conserve the battery power after 60
minutes of no activity.
2.Towake,pushandbrieyholdWakebuttononcontrolpanel.Indicator
lights will show battery status. The unit will return to sleep mode if not
used within 10 minutes.
3. IfSpeedcontrolisnotinoposition,returntoo,andthenadvance
as desired.
4. Blower will run on one or two battery packs. Two packs are used
simultaneously and discharge evenly. Runtime is doubled with two packs.
Indicator lights show battery charge state as in table. Indicator lights
willturnred,thenashredasendofchargeapproaches.Batterieswill
disconnect at the end of their charge and blower will stop.
5. Battery(s) may be swapped for charged batteries at any time.
6. Reduce run speed to minimum required to increase runtime.
1. Connect blower to AC source.
2. Indicator lights will come on and will show battery charge.
3. Indicator lights will be solid green while running on AC, not showing battery
charge.
4. When fan is stopped, indicator lights will show battery charge. The fan will
begin charging after 15 min of idle time.
5.Speedcontrolmustbeoorturnedtoobeforeunitwillrun;asafety
precaution to prevent unwanted fan start.
6. Advance the Speed control as desired.
7. Batteries do not charge while fan is on.