RAMFAN EX50Li User manual

1. If both battery(s) and AC are connected, the battery(s) will begin charging
after 15 minutes of idle time.
2. Indicator lights will show charge state during charging (See insert). Charging
should complete in about 4 hours, with the Indicator lights turning green.
Should the Speed control be turned on during the charge, charging will stop
and the fan will start. Charging will begin again after 15 min of idle time.
3. After charging is complete, the chargers will maintain the battery(s) by
keeping the blower connected to AC.
4. In service storage. Keep batteries topped by keeping blower connected
to AC. Battery charge lights will go out as the controller and batteries are
programmed to reduce leakage to a bare minimum. Use wake up button to
check charge state.
Green >38v (80 - 100% charge)
Orange >33v and 38v (20 - 80% charge)
1 sec Flashing red >27v and 33v (20% charge)
½ sec (Quick) Flash Red Failure to charge in 7 hrs <=36v
LIGHTS GO OFF Low Voltage Cutout Battery <=27v
Green >38v (80 - 100 charge)
Orange >33v and 38v (20 - 80% charge)
1 sec Flashing red >27v and 33v (20% charge)
½ sec (Quick) Flash Red Failure to charge in 4 hrs <=36v
LIGHTS GO OFF Low Voltage Cutout Battery <=27v
Indicator Lights during charge:
GREEN ORANGE EMPTYFLASHING
RED
Charging
Battery
1. RAMFAN R2-360-AH-U lithium-ion battery packs are rated 40v 6Ah. The cells
are Samsung 18650 rated 3Ah.
2.FactorsaectingPerformanceandCyclelife.
• Batterypackswilllastsignicantlylongerwhenruninpairs;therewillbea
lower amp draw on each cell.
•The number of discharge/charge cycles depends on how far down batteries
aredischarged;calledthedepthofdischarge(DoD).Twobatterypackswith
anaverageruntimeof20minutes(50%DoD)orlesswilllastsignicantly
longer than two battery packs with an average runtime of 40 minutes
(100%DoD).
•As delivered, two new battery packs can power the blower for about 46
minutes. This decreases as the cycles pileup as shown in the table. Battery(s)
will need to be replaced as they age.
•Keep the blower attached to AC while not being used. This will keep them
charged and lengthen their service life. An idle battery will slowly lose charge
and possibly become unusable.
• Thenumberofdischarge/chargecyclesdependsonDepthofdischarge.
Depthofdischargeistheaveragecapacityusedperdischarge.Forexample,2
batteries with a 40 min capacity used for 20 minutes on average will be a 50%
Depthofdischarge(DoD).1blonger.
Depth of Discharge in minutes-2 packsDischarge/Charge Cycles (Life)*
46 min. 250-500
20 min. 800+
10 min. 1500+
* Estimate only. Battery packs lose capacity as they are used. This number represents the number of cycles,
after which the battery capacity has reduced to 60-70% of starting capacity, commonly time to replace. If
battery capacity reaches less than what the user requires replace with new.
All Purpose-Battery Ventilator
Euramco Group |San Diego |Luxembourg |Dubai |Ningbo
MADE IN THE USA
Use with all
US Firefighting
literature
Owner's Guide
• DONOTdisassembleblowerformaintenancereasons.
• DonotloosenscrewsoncontrolboxwithoutcontactingEuramcocustomer
service. They are torqued to a setting to achieve water tightness.
•Clean fan periodically to remove accumulated dust or particles from fan
guards, impeller blade and heats ink in rear of controller (ribbed).
Use only biodegradable detergents. If power washing, avoid controller
housing especially gaskets and control panel.
•Contact factory for replacement parts and installation instructions.
• Properlydisposeofbatterypackswhennecessary.Contactyourlocal
hazardous materials on e-waste collection department for details or proper
disposal of lithium-ion batteries.
Maintenance

LB9106
Hot Surface
!
Do Not Touch
Heat Sink or Lights
0-150 ft (0-50m) AWG 14 (2.50 mm)
>150 ft (> 50m) AWG 12 (4.00 mm)
• Electricalshockhazard.Donot
open enclosures.
•DO NOT START with signs of
visible damage.
•Blower is not intended for
operationinexplosiveatmospheres.
•Wear ear protection when close by.
•Keep body parts and loose objects
away from intake of fan.
• Donotmovewhilerunning.
• Operateandrepairbytrained
personnel only.
•Always use grounded plug and
properly ground AC power
receptacle.
•Heat sink becomes hot during
operationandcharging.LED
lights become hot during use.
Donottouch.
•Use with approved, good condition
extensioncordwithground
connector.
READ MANUAL BEFORE STARTING FOR THE FIRST TIME!
Thank you for purchasing the RAMFAN®EX50Li battery powered multi-purpose
ventilator manufactured in the USA by Euramco Safety, Inc.
For more than 30 years Euramco Safety has been on the cutting edge of
industrial,re,andmarineventilationproducts.Eachofourblower/exhausters,
smokeejectors,PPV&LSVfansandaccessoriesrepresentthenesttechnologies
available.Everyproductisconstructedtodemandingandexactspecicationsfor
quality, performance, and reliability.
When human life depends on having a fan that can deliver clean, safe air, you
have only one choice you can trust: RAMFAN.
Exploreourwebsiteandonlinecatalogatwww.euramco.com and discover how
RAMFANcanmakeadierenceintheeld!
All product information in the publication is based on the most current
information available at the time of printing. Euramco Safety, Inc. reserves the
right to make changes at anytime without notice.
PRIOR TO FIRST USE
1. OperateonACvoltage,85-264V,50/60Hz1Φ,forcharginganddischarging.
2. The unit is suitable for use on Ground Fault protected circuits.
3. Should the provided AC connector be unsuitable, replace with desired
connector containing a grounding circuit. Check continuity from ground
terminal to motor shell.
4. PlacebatteriesintoholdersandconnecttoIP66connectors,Fullycharge
priortorstuse.
5. This fan is for emergency service use. Charge fully between runs. Create a
charging protocol.
6. Tocharge,turnthespeedcontrolfullytotheleft(OFF)andthenconnect
toACoutlet.Indicatorlightswillilluminate,andthengoo.Whencharging
commences, indicator lights will show state of charge. Charging should
complete in 3-4 hours, with the indicator lights turning green.
7. ForDCoperationwithACdisconnected,holdthewakebuttonuntil
indicator lights come on showing battery state. Advance speed control.
8. For AC operation, advance speed control.
Warning Labels & Safety Precautions
Specications
Control Panel
Weight 45 lbs 20 kg
Dimensions 21x12x20.6in 534x304x523cm
Power AC Line(85-264V1Φ) 650w
Operating Temp
Range -4°F to 105°F/-20°C to 40°C
Charge Temp
Range 32°F to 105°F/0°C to 40°C
21"
12"
20.6"
2
1
4
3
Battery Wake button
LEDscenelight
BatteryIndicatorLights(L&R)
Speed Control
Battery Operation
AC Operation
The EX50Li is a multi-purpose 18"/46cm ventilator powered by battery(s) or
85-264vsinglephaseAC.TheexibleframecongurationallowsforPPV,Smoke
Ejector or ducted blower use in both normal, horizontal and hanging positions.
Thefancanbetiltedfrom0-36°withintheframeinPPVmode.
Themotor,motorcontrollerandbatteriesarewater-resistant,IP66rated.
Themotorisavariable-speedBLDCmotorcontrolledbyamicroprocessor
integrated with
apowersupply,dualbatterychargersandanLEDlightdriver.
The EX50Li will run with one or two 40v 6Ah Li-ion battery packs. Each pack
yieldsabout23minofoperationatfullpower.Extendedoperationisachieved
by reducing speed. The batteries may be swapped during operation.
AC voltage can be applied while running on batteries and the ventilator will auto-
switch to AC power. Conversely, the AC power can be removed and the unit will
auto-switchtobatterypower,ifsucientchargeremains.
The integrated battery chargers will charge one or two fully discharged battery
packs in 4 hours or less.
LEDscenelightsareintegratedintothefanshroudandhaveahigh-low-o
switch.
Hold to change.
The integrated controller is EMI-protected to prevent interference with radio
communication.
AsimpleControlPanelonthetopofcontrollercontrolsallfunctions.
1.WhenACisdisconnectedandSpeedcontroliso,thecontrollerand
battery(s) will enter a sleep mode to conserve the battery power after 60
minutes of no activity.
2.Towake,pushandbrieyholdWakebuttononcontrolpanel.Indicator
lights will show battery status. The unit will return to sleep mode if not
used within 10 minutes.
3. IfSpeedcontrolisnotinoposition,returntoo,andthenadvance
as desired.
4. Blower will run on one or two battery packs. Two packs are used
simultaneously and discharge evenly. Runtime is doubled with two packs.
Indicator lights show battery charge state as in table. Indicator lights
willturnred,thenashredasendofchargeapproaches.Batterieswill
disconnect at the end of their charge and blower will stop.
5. Battery(s) may be swapped for charged batteries at any time.
6. Reduce run speed to minimum required to increase runtime.
Unit Description
1. Connect blower to AC source.
2. Indicator lights will come on and will show battery charge.
3. Indicator lights will be solid green while running on AC, not showing battery
charge.
4. When fan is stopped, indicator lights will show battery charge. The fan will
begin charging after 15 min of idle time.
5.Speedcontrolmustbeoorturnedtoobeforeunitwillrun;asafety
precaution to prevent unwanted fan start.
6. Advance the Speed control as desired.
7. Batteries do not charge while fan is on.
Other manuals for EX50Li
2
Other RAMFAN Fan manuals
Popular Fan manuals by other brands

Home Decorators Collection
Home Decorators Collection KENSGROVE Series Use and care guide

Hunter
Hunter 23785 Parts guide

Faro Barcelona
Faro Barcelona Islot installation guide

emerio
emerio TFN-114529 instruction manual

Ruck Ventilatoren
Ruck Ventilatoren DVA EC 30 Series Assembly instruction

Adler Europe
Adler Europe AD 2222 user manual

BLAUBERG
BLAUBERG Iso Series user manual

Vent-Axia
Vent-Axia Lo-Carbon Minivent B Installation and wiring instructions

Savoy House
Savoy House 52-ECM-5RV-13 owner's manual

Harvard Apparatus
Harvard Apparatus Inspira ASV MA1 55-7058 user manual

Ruck Ventilatoren
Ruck Ventilatoren EM 100L EC 02 Assembly instruction

Varma
Varma FS40-16JA instruction manual