RI-D440-IM-V02
1
RI-D440 Instrucon Manual
X 1
Safety related noficaon, symbols and instrucons that appear in this
operang manual or on the equipment must be strictly followed to
ensure the safety of personnel as well as the instrument. If the
equipment is not used in a manner specified by the manufacturer it may
impair the protecon provided by the equipment
· Do not use the equipment if there are mechanical damage
· Do not exceed the stated maximum rangs of the device
· No repairs, maintenance or adjustments are possible
· Read the complete instrucon manual prior to installaon or
operang the unit
· The equipment in its installed state must not come into close
proximity to any heang sources, oils, steam, causc vapours or
other unwanted process by-products
· Do not use in hazardous or classified locaon where explosion or
other dangers can be triggered by the device
PRODUCT SAFETY INSTALLATION PRECAUTIONS
Risk of electric shock!
Only to be installed by a competent person
· To prevent the risk of electrocuon, always isolate and lock-off the
power supply to the equipment prior to undertaking any work
· Always confirm absence of electricity prior to starng work using
appropriate voltage detecon equipment
· Wiring shall be done strictly according to the terminal layout
· Confirm that all connecons are correct before energizing the
equipment
· Roung of cables shall be way from any internal EMI source
· Copper cable should be used
· All wiring to be in accordance with applicable local standards
Specificaons Accuracy
Wiring Input 3Ø 4 wire
1Ø 2 wire - P1, P2, P3 Voltage V L-N and V L-L ±0.5% of full scale
Rated Input Voltage 3x 60...300V AC (L-N), 104..520V AC (L-L) Current ±0.5% of full scale
Frequency 45...65Hz Frequency for L-N > 20V, L-L > 35V ±0.1% of full scale
CT Primary 5...10,000A configurable Acve, Reacve and Apparent Power 1%
CT Secondary 0.01...1(1.2)A (Meter Input: 330mV) Power Factor ±0.01 of Unity
VT Primary 100V...10kV AC (L-L) configurable Acve Energy Class 1 (IEC/EN62053-21)
VT Secondary 100...500V AC (L-L) configurable Reacve Energy Class 2 (IEC/EN62053-23)
Auxiliary / Voltage Rated Burden Supplied from V1 only / < 8VA
Display Update Rate 1 sec all parameters Wh Resoluon and Default Pulse Weight
Operang / Storage Temperature -10…55°C / -20…75°C
Example
If CT Primary = 200A (CT rao = 200/1 = 200) & VT = 350/350V (VT Rao = 1)
Wh resoluon = 1kWh (200 x 1 = <1500) | Pulse O/P default = 1kWh/pulse
Humidity 0...85% non-condensing
Protecon Degree (IEC/EN60529) IP54 (front of Housing), IP20 (terminals)
Communicaon Modbus RTU over RS485
MBus (EN13757)
CT Rao x VT Rao <15 <150 <1500 <15k <150k
Wh / VAh / VArh 0.01k 0.1k 1k 0.01M 0.1M
INT 0.001k 0.01k 0.1k 1k 0.01M
DIN rail mounted, this device must be installed within a
suitable IP rated enclosure. Indoor use only.
Installaon category: III (300V L-N)
Protecon Class: II
Polluon degree: II
Altude: up to 2000 m
All terminal covers must be fied aer wiring
MECHANICAL INSTALLATION
DISMOUNT
EO&E: Document subject to change
1x 3Ø
1x 1Ø
RI-D440-G-C
RI-D440-G-MB
RTU
Pulse SO
RI-D440-IM-V02
2
1 RJ45 cable
2 Fuse class CC UL / fast acng
3 Phase 600V/Single Phase 250V
3 Supply 31 addional meters (32 total)
4 For ’Volt-free’ PLC or digital input, voltage must
be provided by the addion of a DC PSU
5 For Single Phase Easywire CT - Set Phase
Network to 1P2W-P1, Voltage Reference V1
must be same phase as CT. Connect V2/V3 to N.
WIRING
Modbus / MBus
Wiring Topology
Daisy Chain Star Network
Modbus ü û
MBus ü ü
A | B
+ | -
1 | 2
Typical Modbus
configuraon shown
For MBus interface
follow Wiring
Topology below
500m Max, ≤ 32 meters
No. Meters ≤ 5 ≤ 10 ≤ 20 ≤ 32
Fuse Rang 0.5A 1A 1.5A 2A
0.5 Nm
Max
Single Core 0.5 > 4mm2
Ø 2.5mm Max Stranded 0.5 > 2.5mm2
7mm +
Ø 2.5mm
CT phase rotaon is
RH/LH dependant
refer to Configuraon
3P4W or
1P2W P1,P2 or P3
RI-D440-IM-V02
3
D440-G-C
D440-G-MB
Seng Default Adjustment Range Network
& CT
Must
configure
VT
Adjust if
Using VT
Comms
Modbus /
MBus
Pulse O/P
Adjust if
ulised
System
Sengs
Oponal
1 1 Change Password 1000 NO / YES (0000 - 9998) ü
2 2 Phase Network Selecon 3P4W 3P4W, 1P2W-P1/P2/P3 ü
3 3 CT Secondary 1 Non-adjustable
4 4 CT Primary (see CT Label) 1 5 > 10000A ü
5 5 PT Secondary 350 100 > 500V ü
6 6 PT Primary 350 100 > 10000V ü
7 7 Slave ID Modbus:
MBus (Primary ID):
1
1
1 > 255
1 > 250 ü
8 8 Baud rate Modbus:
MBus:
9600
2400
300 > 19200 bps
1200 > 9600 ü
9 9 Parity Modbus:
MBus:
None
Even
None / Odd / Even
Even ü
10 10 Stop Bit Modbus:
MBus:
1
1
1 / 2
1 ü
11 11 Back Light Off (0000 = Never) 0000 0 > 7200 Sec ü
12 12 Demand interval method Sliding Sliding / Fixed ü
13 13 Demand interval duraon 15 1 > 30 min ü
14 14 Demand interval length 1 1 > 30 min ü
15 15 Pulse Weight 0.10 0.01 > 9.99 kWh/imp ü
16 16 Pulse Duraon 200 50 > 300 mS ü
X 17 MBus Secondary ID Serial # 0000 0000 > 9999 9999 ü
17 18 Factory Default No No / Yes Does not reset energy & demand values ü
18 19 Reset Energy & Demand No No / Yes (Password +1) Once entered, reset each value individually ü
CONFIGURATION
CT Phase Rotaon - RH or LH, check/change in normal operang mode
1. Hold 3 sec to check
2. Hold again to change
RH
LH
Step A: Enter Configuraon Menu Step B: Configure each seng, as required, referring to
Config Table below, using the buons as follow:
1 Press once to make digit or opon flash, press again to
move flashing cursor
2 Press to change digit or opon, press to move
cursor posion as required
3 Press to save and move to next seng opon, Exit
menu once all sengs are configured (see Step A)
Hold 3 Secs to
Enter Config
(same to Exit)
Password = 1000
(Refer to Step B)
2
1
RI-D440-IM-V02
4
OPERATION
1 Display Symbols:
Avg Average of 3-phase
tOt Total of 3-phase
MD Max Demand
L-N Line to Neutral
RS485 communicaon in progress
2 Measurement Units (refer to Funcons Table below)
V, kWh, kVArh, kVAh, A, Hz, kW, kVAr, kVA
3 Navigaon Buons: Change PARAMETER
Change PAGE
(hold 10 sec: Serial #)
4 Integraon of Energy Indicator (blinks at rate of INT)
x1
Voltage x2
Current x3
V/A/F/PF x4
PF & Power
Avg Voltage (V L-N)
Acve Energy (kWh)
Phase Voltage
(V L-N)
Phase Current
(A)
Avg Voltage (V L-N)
Total Current (A)
Frequency (Hz)
Avg Power Factor
Phase Power Factor
Frequency (Hz)
x1 Avg Voltage (V L-N)
Reacve Energy (kVArh)
Phase Voltage
(V L-L)
Avg Voltage (V L-L)
Total Current (A)
Frequency (Hz)
Avg Power Factor
Phase Acve Power (kW)
x2 Phase Reacve Power (kVAr)
x3 Phase Apparent Power (kVA)
x4 tOt Acve Power (kW)
x5 tOt Reacve Power (kVAr)
x6 tOt Apparrent Power (kVA)
x7 tOt Acve Max MD (kW)
x8 tOt Reacve Max MD (kVAr)
Energy
Parameters in BOLD not
displayed for 1P2W
Voltage Phase Rotaon
Hold 3 Sec
OK CLK: L1 → L2 → L3
ANTI-CK: Incorrect Order
INVAL Id: Missing Phase û
ü
Rayleigh Instruments Limited (Head Office)
Raytel House, Cutlers Road, South Woodham Ferrers, Chelmsford, Essex. CM3 5WA
W: www.rayleigh.com E: sales@rayleigh.com
Rayleigh Instruments Limited SP. Z o.o. (European Office)
Ul. Aleje Jerozolimskie 214, Warsaw, Poland, 02-486
W: www.rayleigh.pl E: sales@rayleigh.pl

Other Rayleigh Instruments Measuring Instrument manuals

Rayleigh Instruments RI-D384-C User manual

Rayleigh Instruments

Rayleigh Instruments RI-D384-C User manual

Rayleigh Instruments RI-F200 User manual

Rayleigh Instruments

Rayleigh Instruments RI-F200 User manual

Rayleigh Instruments RI-F300 User manual

Rayleigh Instruments

Rayleigh Instruments RI-F300 User manual

Rayleigh Instruments RI-F220 User manual

Rayleigh Instruments

Rayleigh Instruments RI-F220 User manual

Popular Measuring Instrument manuals by other brands

ALFAMATIC Press-Right installation manual

ALFAMATIC

ALFAMATIC Press-Right installation manual

Powerfix Profi 275222 Operation and safety notes

Powerfix Profi

Powerfix Profi 275222 Operation and safety notes

Kusam-meco KM 2783 Operation manual

Kusam-meco

Kusam-meco KM 2783 Operation manual

Bosch Professional GIC 4-23 C Original instructions

Bosch

Bosch Professional GIC 4-23 C Original instructions

YOKOGAWA ADMAG TI Series user manual

YOKOGAWA

YOKOGAWA ADMAG TI Series user manual

Huazheng HZSM-701 Operation manual

Huazheng

Huazheng HZSM-701 Operation manual

Shodex OHpak LB-800 Series Operation manual

Shodex

Shodex OHpak LB-800 Series Operation manual

Vaisala MGP260 Series user guide

Vaisala

Vaisala MGP260 Series user guide

GeoMax Zenith60 Series user manual

GeoMax

GeoMax Zenith60 Series user manual

Simex SRP-73-XC user manual

Simex

Simex SRP-73-XC user manual

KERN MBC-A01 operating instructions

KERN

KERN MBC-A01 operating instructions

Milwaukee SM801 user manual

Milwaukee

Milwaukee SM801 user manual

PCE Instruments PCE-SFS 10 user manual

PCE Instruments

PCE Instruments PCE-SFS 10 user manual

Sonata Ultrasonic Water Meter manual

Sonata

Sonata Ultrasonic Water Meter manual

LaserLiner 4K5 SL 350 manual

LaserLiner

LaserLiner 4K5 SL 350 manual

National Instruments NI 5102 Getting started guide

National Instruments

National Instruments NI 5102 Getting started guide

Abtus ABT5200 instruction manual

Abtus

Abtus ABT5200 instruction manual

METREL MD 9250 user manual

METREL

METREL MD 9250 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.