RayLight HERA Technical manual

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
contact@
raylight.fr
Internal
TECHNICAL DOCUMENT / FICHE TECHNIQUE
STROBES / NAVIGATION / POSITION
HERMES / HEMERA / HERA
MOST POWERFUL
FLASH
20,000 LUMENS
EMC EMI
INTERFERENCE
FREE
LOW POWER AND
CONSTANT CURRENT
FOR ALL AIRCRAFT
VERYLIGHT
WEIGHT
WATER AND DUST
PROOF

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 2/34
Internal
Table des matières
1. Product Datasheet (UK) ................................................................................................................. 3
1.1. Products description ......................................................................................................................... 3
1.2. Terms of use ...................................................................................................................................... 4
1.3. Drawing ............................................................................................................................................. 6
1.4. Specification table ............................................................................................................................. 8
1.5. Frequently Asked Questions ............................................................................................................. 9
1.6. Contact information .......................................................................................................................... 9
2. Installation manual ...................................................................................................................... 10
2.1. Inventory ......................................................................................................................................... 10
2.1.1. HERA .......................................................................................................................................................10
2.1.2. HERMES ...................................................................................................................................................10
2.1.3. HEMERA ..................................................................................................................................................10
2.1.4. Not Included ............................................................................................................................................11
2.2. Assembly ......................................................................................................................................... 12
2.3. Connection ...................................................................................................................................... 13
2.3.1. HERA .......................................................................................................................................................13
2.3.2. HERMES & HEMERA ................................................................................................................................14
3. Non-compliance declaration form (UK) ...................................................................................... 16
FICHE TECHNIQUE (FR) .......................................................................................................................... 19
1. Informations produits (FR) .......................................................................................................... 20
1.1. Description des produits ................................................................................................................. 20
1.2. Limitations générales ...................................................................................................................... 21
1.3. Plan .................................................................................................................................................. 23
1.4. Tableau des caractéristiques ........................................................................................................... 25
1.5. Foire Aux Questions ........................................................................................................................ 26
1.6. Informations de contact .................................................................................................................. 26
2. Manuel d’installation- Raylight Technologies ............................................................................. 27
2.1. Inventaire ........................................................................................................................................ 27
2.1.1. HERA .......................................................................................................................................................27
2.1.2. HERMES ...................................................................................................................................................27
2.1.3. HEMERA ..................................................................................................................................................27
2.1.4. Non-inclus ...............................................................................................................................................28
2.2. Assemblage des strobes .................................................................................................................. 29
2.3. Branchement du générateur ........................................................................................................... 30
2.3.1. HERA .......................................................................................................................................................30
2.3.2. HERMES & HEMERA ................................................................................................................................31
3. Formulaire de déclaration de non-conformité (FR) .................................................................... 33

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 3/34
Internal
1. Product Datasheet (UK)
1.1. Products description
HEMERA - 3 lights
Navigation/ Stroboscope /Position:
- 1 red light +white strobe
- 1 green light + white strobe
- 1 white strobe
HERMES- 2 lights
Navigation/ Stroboscope /Position:
- 1 red light + white strobe
- 1 green light + white strobe
HERA- 1 light
Stroboscope: 1 white strobe

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 4/34
Internal
1.2. Terms of use
Temperature range -40° to 70°Celsius (- 40° to 158° Fahrenheit).
The voltage must not exceed 20 volts.
Wire cross-sections must be used according to the technical specifications (0,25
to 0,75 mm², 0,5mm² recommended).
Thoroughly verify that the wires that are being used are in good condition: not
cut nor damaged.
Electrical connexions are carried out by connectors that need wires tripping to be
connected.
Raylight Technologies can in no way be held responsible for the mounting of the
device and it is strongly advised to use of professionals for the assembly.
The generator has to be protected from:
Moisture: exposed to an environment inferior to 80% of humidity level.
Water: sheltered from rain, sprinklers …
Flammable or explosive material: there must be a minimum of 1m between the
source and the generator
Heavy mechanical stress: vibrations, twists, inflections, shears etc… that may
cause rupture of the support resulting in damage of the generator (risks of
electrical short-circuits).
Do not power on the generator if LEDs are not connected
Do not look at the strobe when operate less than 50 cm
Used on not certified aircraft only

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 5/34
Internal
During the transportation/storage/set up, be careful not to impact/chock/drop the
generator.
During the mounting, please strictly follow the instruction guide provided with
the device and the wiring recommendations and tools.
Raylight Technologies does not guarantee its products outside these limitations.
The mounting of the device must be done under these conditions:
Strictly respect the assembly instructions.
The assembly order must comply to the instructions.
The wires must go through foam inserts to ensure sealing.
The polarity « Led + / Led- » must be respect: short-circuits risks, creation of a
hot spot leading to the destruction of the LED board.
The tightening of the polycarbonate protective layer ULV0 torque must be
done by hand: tighten with a manual screwdriver without forcing, do not use
a drill (see assembly instructions). Tightening must be enough to crush the
sealing foam to ensure the sealing of the LED board.
Place the light device at more than one meter from inflammables or
explosives (example: fuel tank).
In case of a purchase of the device without the lens, Raylight Technologies
absolves itself of all responsibility.
Raylight Technologies does not guarantee its products outside these limitations.
Declare a non-compliance
Raylight Technologies reserves the right to accept the non-compliance upon receipt
of the defective product.
Shipping charges of a potentially defective product are the responsibility of the
customer.
If the non-compliance is proven, Raylight Technologies will issue a refund of the
shipping charges.

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 6/34
Internal
1.3. Drawing
Simple Generator
HERA
Front V
iew
Top View
Double and Triple Generator
HERMES & HEMERA
Front V
iew
Top View

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 7/34
Internal
LENS
HERA & HERMES & HEMERA
Side View
Top View

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 8/34
Internal
1.4. Specification table
HERA
HERMES
HEMERA
Lumens
20,000 20,000 X 2 13,300 X 3
Candelas
1,900 1,900 X 2 1,267 X 3
Number of white LEDS
20 20 X 2 20 X 3
Number of RWG LEDs | Position lights
7 X 2
Uniform current drawn | A
0,4 0,4 – 1,2
Voltage | Vdc
10 - 15
Electrical protection
Over-Voltage
and reversal
polarity
Over-Voltage and reversal polarity
Protection for disconnected LEDs
Short circuit protection for LEDs
Frequency | synchronised flashes permn
55 - 65
Type of lens
Polycarbonate Anti UV (ULV 0)
Total weight (+/- 5) | g
lbs
160
0,353
540
1,19
580
1,28
Strobe weight | g
lbs
40
0,88
Generator weight (+/- 5) | g
lbs
120
0,264
450
0,992
Strobe Dimensions | L x W x H | in
mm
4,72 x 1,77 x 1,38
120 x 45 x 35
Fastening
Included
Between axis | in
mm
4
101.6
Generator Dimensions | L x W x H | in
mm
3,5 x 2,2 x 2,2
90 x 57 x 57
3,5 x 2,2 x 2,2
90 x 57 x 57
Between generator's axis | L x W in
mm
3,1 x 1,6
78 x 40
3,1 x 1,6
78 x 40
Generator electrical connection
terminal blocks and heat-shrink welding sleeve
Without tools - no length limit
Section from 0,25 to 0,75 mm²
AWG 19 to 23
Gauge 29 to Gauge 22

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 9/34
Internal
1.5. Frequently Asked Questions
You can check our FAQ on our website in the support section.
1.6. Contact information
For further information, please contact :
RAYLIGHT TECHNOLOGIES
contact[AT]raylight.fr
+33 (0)7.67.73.74.76
www.raylight.fr
DECLARE NON-COMPLIANCE:
contact[AT]raylight.fr
Form: https://www.raylight.fr/en/support/declaration-of-non-compliance-form/

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 10/34
Internal
2. Installation manual
2.1. Inventory
2.1.1. HERA
2.1.2. HERMES
2.1.3. HEMERA
Welding sleeve
X9
Welding sleeve
X9

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 11/34
Internal
2.1.4. Not Included
Breakers and wires are not included.

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 12/34
Internal
2.2. Assembly
-
Insert two
wires
into the holes (1) of
the foam and the LED board.
- Connect(2) + LED and – LED to one of
the generator output (see image
thereafter).
- Place the screws: M3 screw, washer,
PTFE shoulder washer, strobes
assembly, wing tips of your plane,
washer and nut. Gently tighten by
hand.

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 13/34
Internal
2.3. Connection
2.3.1. HERA
Insert the wires into the holes of the corresponding terminal block and tighten the
screws. No solder is necessary.
Wiring Diagram
Generator

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 14/34
Internal
2.3.2. HERMES & HEMERA
Connect Power, S1, S2, S3 using welding sleeve, as shown below.
Wiring Diagram
Generator
S1
S2
S3
POWER
LED +
LED +
LED +
S2
S1
S3
GND
POS/NAV
Option
HEMERA

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 15/34
Internal
Step 1: Strip the threads over about 0.2
in.
Step 2: Insert the 2 conductors inside
the welding sleeve and make sure they
are overlapping one another.
Step 3: With an hot air gun
(180°Celsius), heat up the sleeve at it
center where the solder is located and
wait for it to melt.
This section applies to HERMES and HEMERA strobes.
For HERMES strobes, unused S3 wires must be insulated.

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 16/34
Internal
3. Non-compliance declaration form (UK)
Use the form below to declare a non-compliance.
With the goal of dealing with non-compliance in the shortest possible time, please
fill in a maximum of information in the form below.
The fields followed by a star "*" are required.
Raylight Technologies will not provide any declaration of non-compliance by
phone or email.
Last Name*
First name*
Phone*
Email*
Postal Address
Country
Company*
Website
Seller*
Has the product been damaged from
shocks, impacts*?
Involved
product*
Batch or
serial number*
Invoice or delivery number*
When did you notice the non
-
compliance*?
Date of detection*
Please enter a date in the format
DD/MM/YYYY

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 17/34
Internal
What did you do* ?
☐ I disconnected the device
☐ I placed the device neatly in a
package making sure it as well
protected
☐ I shipped the device to my seller
☐ Other actions (please specify in
your message)
☐ I placed the device back in its
original packaging
☐ The device was severely
damaged, so I threw it.
☐ I tried to repair the device by
deriding it
☐ I shipped he device to Raylight
Technologies
Comments*
We thank you in advance for detailing to us under what conditions you used the device.
Declaration of accuracy *
☐ I certify on honor to be the person I declare to be
☐ I certify on the honor that my statement is accurate
Drone in*
Date*
Signature
*

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 18/34
Internal

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 19/34
Internal
FICHE TECHNIQUE (FR)
STROBES / NAVIGATION / POSITION
HERMES/HEMERA / HERA
LE PLUS PUISSANT
FLASH
20,000 LUMENS
SANS PARASITE RADIO
FAIBLE
CONSOMMATION
COURANT CONSTANT
POUR TOUS LES
AERONEFS
TRES LEGER RESISTANT A L’EAU ET A
LA POUSSIERE

FTECH-2022-000002-V6
Last Update: 20/07/2022
RAYLIGHT TECHNOLOGIES
Aérodrome du Versoud
38420 LE VERSOUD
Page 20/34
Internal
1. Informations produits (FR)
1.1. Description des produits
HEMERA - 3 dispositifs lumineux
Navigation/Stroboscope/Position :
- 1 rouge + strobe blanc
- 1 vert + strobe blanc
- 1 strobe blanc
HERMES - 2 dispositifs lumineux
Navigation/Stroboscope/Position :
- 1 rouge + strobe blanc
- 1 vert + strobe blanc
HERA - 1 dispositif lumineux
Stroboscope: 1 strobe blanc
This manual suits for next models
2
Table of contents
Languages:
Other RayLight Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

NEO TOOLS
NEO TOOLS 30SMD Original user manual

Heitronic
Heitronic 35374 Installation and operating instructions

Robert Juliat
Robert Juliat 1015 B Technical file

MELINERA
MELINERA 288593 Operation and safety notes

BRFO
BRFO BR-1915G user manual

Larson Electronics
Larson Electronics HID-35-RC-W quick start guide