EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Raymarine
  6. •
  7. Boating Equipment
  8. •
  9. Raymarine ST40 User manual

Raymarine ST40 User manual

Other manuals for ST40

10

Other Raymarine Boating Equipment manuals

Raymarine ST70 Instrument User manual

Raymarine

Raymarine ST70 Instrument User manual

Raymarine Dragonfly-4 DV User manual

Raymarine

Raymarine Dragonfly-4 DV User manual

Raymarine A series User manual

Raymarine

Raymarine A series User manual

Raymarine ST40 User guide

Raymarine

Raymarine ST40 User guide

Popular Boating Equipment manuals by other brands

Ideal Windlass CWM Installation, operation & maintenance instructions

Ideal Windlass

Ideal Windlass CWM Installation, operation & maintenance instructions

Access BIMINI Assembly instructions

Access

Access BIMINI Assembly instructions

Floe VSD 6000 Assembly instructions

Floe

Floe VSD 6000 Assembly instructions

Faun C40 Trackway user manual

Faun

Faun C40 Trackway user manual

Exalto 240BS manual

Exalto

Exalto 240BS manual

Hobie Mirage 360 manual

Hobie

Hobie Mirage 360 manual

Dowco V322 CC - 2019 installation instructions

Dowco

Dowco V322 CC - 2019 installation instructions

Humphree HCS-5 installation manual

Humphree

Humphree HCS-5 installation manual

Vetus BOW4512D Operation manual and installation instructions

Vetus

Vetus BOW4512D Operation manual and installation instructions

Dock Doctors SLIDING BOARDING STEP Assembly instructions

Dock Doctors

Dock Doctors SLIDING BOARDING STEP Assembly instructions

Mastervolt Mass Combi 12/2000-100 Quick installation

Mastervolt

Mastervolt Mass Combi 12/2000-100 Quick installation

Zattini Group bamar BOXTRON E14S Use and maintenance instruction manual

Zattini Group

Zattini Group bamar BOXTRON E14S Use and maintenance instruction manual

SeaView PM5-FMD-8 installation instructions

SeaView

SeaView PM5-FMD-8 installation instructions

Vetus HTANK installation manual

Vetus

Vetus HTANK installation manual

Grammer AVENTO MSG 65/511 Repair manual

Grammer

Grammer AVENTO MSG 65/511 Repair manual

Furuno TZTL12F installation manual

Furuno

Furuno TZTL12F installation manual

Harken 944 instruction sheet

Harken

Harken 944 instruction sheet

ShoreLand'r DUB 2314 install guide

ShoreLand'r

ShoreLand'r DUB 2314 install guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Distributed by
Any reference to Raytheon or
RTN in this manual should be
interpreted as Raymarine.
The names Raytheon and RTN
are owned by the
Raytheon Company.
Adjusting display backlighting/contrast
Normal operation
ST40 Compass Instrument - quick reference guide
orTo exit adjust mode press or wait for 5 second timeout
LEVEL 1 LEVEL 1
OFF LEVEL 2LEVEL 3LEVEL 2
To enter adjust mode, press for 1 second to adjust BACKLIGHTING and a further 1 second to adjust CONTRAST
SWITCH ON
Compass
heading
3 seconds
Set
alarm
level
Alarm on/off
Times out to the
Compass heading
screen after
5 seconds.
Off course
alarm
values
Locked
heading
Auto locked
heading
Course computer
sets auto lock
Course computer
sets auto lock
+
-
Momentary
With Set alarm level screen displayed,
to save the alarm level and return to
normal operation.
and keys simultaneously
press the
86050_2.p65 18/04/01, 16:551
Calibration
ST40 Compass Instrument - quick reference guide
Document number: 86050_2 (to be used with handbook: 81161_2)
Date: 1 May 2001
USER
CALIBRATION
for 2 seconds
Hold down
and
INTERMEDIATE
CALIBRATION
Software
version
Hold down
and
for 4 seconds
M
T
Instrument
status
User
cal
Set compass
heading
response
Set
variation
Linearise
transducer
Deviation
2 turns
minimum
Set
True/
Magnetic
Set
heading
alignment
Linearisation
successful
Master Repeater
+
-
+
-
Bypass
linearisation
To leave any calibration routine and
return to normal operation,
for approximately 2 seconds
andhold down
If there is no key activity with either
the User cal or Software version
screen displayed, calibration will time
out to normal operation after 5 seconds
+
-
86050_2.p65 18/04/01, 16:552