1
To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is NOT connected BEFORE installing door control.
• Connect ONLY to 12 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
• Install door control within sight of garage door, out of reach of children at a minimum
height of 5 feet (1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door control push buttons or remote control
transmitters.
• Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no
obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross
path of closing garage door.
MULTI-FUNCTION CONTROL PANEL (SECURITY+ 2.0TM)
MODEL 882RGD
Feature Overview
Multi-Function
Control Panel
Safety Reversing
Sensors
Yellow
LEARN Button
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are
prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards for Home or office use. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
For use with Security+ 2.0TM Garage Door Openers. All Security+ 2.0TM Garage Door Openers have a
yellow Learn button and a yellow antenna wire. The features are adjustable and may be turned off
or on as desired. Refer to the Feature Settings section.
LIGHT BUTTON
Press the LIGHT button to turn the garage door opener lights on or off. When the lights are turned
on they will stay on until the LIGHT button is pressed again, or until the garage door opener is
activated. Once the garage door opener is activated the lights will turn off after the specified period
of time (the factory setting is 4-1/2 minutes). The LIGHT button will not control the lights when the
door is in motion.
LOCK
The LOCK feature is designed to prevent activation of the garage door opener from remote controls
while still allowing activation from the door control and keyless entry. This feature is useful for
added peace of mind when the home is empty (i.e. vacation).
MAINTENANCE ALERT SYSTEM (MAS)
This feature assists the homeowner in ensuring the garage door opener system stays in good
working condition. When the garage door opener needs to be serviced (approximately 4500 garage
door opener cycles) the command (yellow) and service (red) LEDs will begin to alternately flash
back and forth. The MAS feature can be activated at time of installation. Contact your installing
dealer for service. The factory setting for the MAS feature is off.

2
RED
WHITE
WHITE
GREY
WH
WHITE
E
Installation
Install the door control within sight of the garage door at a minimum height of 5 feet (1.5 m)
where small children cannot reach, and away from the moving parts of the door. For gang box
installations it is not necessary to drill holes or install the drywall anchors. Use the existing holes
in the gang box.
NOTE: Pre-wiring means that your garage already has wires installed for the door control. If this a
new installation, or if you are not replacing an existing door control, it may be necessary to run
new wire from the garage door opener to this door control.
WIRE THE DOOR CONTROL
1
2
3
1
2
3
7/16" (11 mm)
Disconnect electrical and battery power
(if applicable) to the garage door opener.
Strip 7/16" (11 mm) of insulation from one
end of the wire and separate the wires.
Connect one wire to each of the screws on
the back of the door control. The wires can
be connected to either screw.
PRE-WIRED INSTALLATIONS: Choose any two wires
to connect, but make note of which wires are used.
WIRE TO GARAGE DOOR OPENER
Run the white and red/white wire from the
door control to the garage door opener.
Attach the wire to the wall and ceiling with
staples (not provided). Strip 7/16" (11 mm)
of insulation from the end of the wire near
the garage door opener.
Connect the wire to the red and white
terminals on the garage door opener. The
wires can be connected to either terminal.
Reconnect electrical and battery power
(if applicable) to the garage door opener. The
command LED behind the push bar on the
door control will blink if installed correctly.
To synchronize the garage door opener and
the door control, press the push bar up to 3
times, until the garage door opener activates.
PRE-WIRED INSTALLATIONS: Connect the same
wires to the garage door opener that were
previously connected to the door control.
To insert or release wire, push
in tab with screwdriver tip.
GANG BOXDRYWALL
6ABx1-1/4" Drywall Anchors 6-32x1"
HARDWARE
1
2
3
4
5
6
MOUNT THE DOOR CONTROL
Mark the location of the bottom
mounting hole and drill a 5/32"
(4 mm) hole.
Install the bottom screw, allowing
1/8" (3 mm) to protrude from the
wall.
Position the bottom hole of the
door control over the screw and
slide down into place.
Lift the push bar up and mark
the top hole.
Remove the door control from
the wall and drill a 5/32" (4 mm)
hole for the top screw.
Position the bottom hole of the
door control over the screw and
slide down into place. Attach the
top screw.
- Wall -
1
2
35
6
4
7/16" (11 mm)

3
TO ADD, REPROGRAM, OR CHANGE A REMOTE CONTROL/KEYLESS ENTRY PIN
NOTE: The following steps are for standard accessories. If programming is unsuccessful, refer to your accessory or garage door opener manual for programming information.
Program
Operation
PUSH BAR
Press the push bar to open or close the door.
GARAGE DOOR OPENER LIGHTS
Press the LIGHT button to turn the garage door opener lights on or off. When the lights are turned
on they will stay on until the LIGHT button is pressed again, or until the garage door opener is
activated. Once the garage door opener is activated the lights will turn off after the specified period
of time (the factory setting is 4-1/2 minutes). The LIGHT button will not control the lights when the
door is in motion.
Light Feature
The lights will turn on when someone enters through the open garage door and the safety
reversing sensor infrared beam is broken. If using the garage door opener light as a work light,
turn the light on using the light button on the wall control or the light will turn off after a set
amount of time.
LIGHT Button
Push Bar
Press and release the LEARN button on
the door control to enter Programming
Mode.
Press and release the LEARN button
again, the LED will flash once.
Press the button on the remote
control that you wish to operate
your garage door.
Enter a 4-digit personal
identification number (PIN) of your
choice on the keyless entry keypad.
Then press the ENTER button.
The garage door opener lights will flash (or two clicks will be heard) when the code has been programmed.
Repeat the steps above for programming additional remote controls or keyless entry devices.
PIN
?? ??
12ABC 3DEF
4GHI 5JKL 6MNO
7PRS 8TUV 9WXY
0QZ
*#
ENTER
0QZ
*#
ENTER
OR
1 2 3a 3b
Service LED
LEARN Button
LOCK Button
Command LED

FOR SERVICE DIAL OUR TOLL FREE NUMBER:
1-800-472-9667
www.raynor.com
Feature Settings
LOCK
Activate:
NOTE: Your remote controls will NOT work when LOCK
mode is active however your keyless entry will still allow
access to your garage.
Press and hold the LOCK button for 2 seconds. The
command LED will flash as long as the lock feature is
activated and your handheld remote control will not
operate your door at this time.
Deactivate:
Press and hold the LOCK button again for 2 seconds. The
command LED will stop flashing and normal operation will
resume.
LIGHT
To change the amount of time the garage door opener lights
will stay on (default time is 4-1/2 Minutes):
Press and hold the LOCK button until the garage door opener
lights flash.* The garage door opener lights will then indicate the
current light duration by flashing up to 4 times (see table below).
NUMBER OF TIMES GARAGE DOOR
OPENER LIGHTS FLASH
TIME THE GARAGE DOOR OPENER
LIGHT STAYS ON
1 1 ½ Minutes
2 2 ½ Minutes
3 3 ½ Minutes
4 4 ½ Minutes
MAINTENANCE ALERT SYSTEM (MAS)
Activate/Deactivate:
NOTE: Factory setting is off.
Press and hold the LEARN button. Then press the LIGHT
button. The service LED will flash the status; Activated is 2
flashes and deactivated is 3 flashes.
Warranty
ONE YEAR LIMITED WARRANTY
Raynor warrants to the first consumer purchaser of this product that it is free from defect in
materials and/or workmanship for a period of 1 year from the date of purchase.
To change the light duration time repeat the steps above until the
lights flashes indicate your desired time frame.
Light Feature
NOTE: Factory setting is on.
This feature will turn on the garage door opener lights when
the safety reversing sensors beam has been broken.
Deactivate:
Start with the garage door opener lights off. Press and hold the
LIGHT button to turn on the light, continue to hold until the light
turns off.*
Activate:
Start with the garage door opener lights on. Press and hold the
LIGHT button to turn off the light, continue to hold until the light
turns on.*
* Approximately 10 seconds
LOCK Button
Command LED
LOCK Button
LIGHT Button
Command LED
LEARN Button
LIGHT Button
Service LED