manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. RDL
  6. •
  7. Switch
  8. •
  9. RDL RACK-UP RU-VSX4 User manual

RDL RACK-UP RU-VSX4 User manual

RACK-UP®SERIES
Model RU-VSX4
4-Input Video Switcher
Loop-Through Output from each Input
Vertical Interval Switching
Local or Remote Control
10 MHz Bandwidth, NTSC or PAL
Open-Collector Outputs
All Solid-State Switching
The RU-VSX4is part of the group of RDL RACK-UP products. The compact design permits high-density installations, with three products mounted
in a single rack unit. The RU-VSX4 may be used alone, or mounted using a wide variety of RACK-UP series options.
APPLICATION: The RU-VSX4 is the ideal choice in most applications where four video signals need to
be switched to a single output. The RU-VSX4 has two rear-panel jacks for each of the four video bridging
input stages. One jack is for the input signal; the other is a loop-through output of the source signal. If
75-termination of the input signal is required, the terminator (provided) is plugged onto the LOOP OUT
jack. The output video signal is 75 back-terminated to provide unity gain into a 75 terminated input.
The front panel features 4 high-reliability, keyboard-style pushbuttons with LED indicators corresponding
to each video input. The LED indicators show which video source is active. If the button for an active
source is pushed, all video sources are turned off until the next source selection.
A front panel LOCAL/REMOTE toggle switch activates either the front-panel buttons or a rear-panel
connected remote control. In the REMOTE mode, the inputs are selected by an external momentary
switch or open-collector closure to ground. Five remote input terminals are provided; one for each video
source, and one to shut off all video inputs. Installing a jumper from the CTRL OFF terminal to ground
permits the RU-VSX4 to be controlled by equipment providing a continuous closure only when a source is
to be switched on. In this mode, the RU-VSX4 may be controlled by an RDL D SERIES-RC4RU
wall-mount 4-button remote control, or OEM equipment. When a video source is selected, the RU-VSX4
provides an open-collector 50 mA output to control other equipment or modules.
When a video source is requested, either from the front panel or by remote, the RU-VSX4 waits until the
next vertical interval to switch to the requested video source. If no video is present then the switch occurs
instantly. This feature avoids the screen roll typically associated with unsynced video switchers.
Wherever a video switcher is needed to provide wide-band video source selection, local or remote control,
reliability, compactness and unsurpassed versatility, the RU-VSX4 is the ideal choice.
RDL 659 6th St. Prescott, AZ., USA 86301 (928) 443-9391 FAX (928) 443-9392 www.rdlnet.com
RACK-UP®SERIES
Model RU-VSX4
4-Input Video Switcher
TYPICAL PERFORMANCE
Input Impedance: 5 kBridging 75 Line
Gain: Unity, 75 terminated Input; 75 terminated Output
Load Impedance: 75 
Outputs (5): 4 Loop Out from Input Signals; 1 Amplified OUTPUT
Operating Signal Level: 0.5 to 1 V p-p
Frequency Response: 10 Hz to 10 MHz (+/- 0.35 dB)
Noise: < -70 dB below 1 V p-p
Crosstalk: < -55 dB
Off Attenuation: > 65 dB
Differential Gain: 0.1%
Differential Phase: 0.3 degree
Connector Type: BNC, gold plated
External Control Inputs: Electronic or mechanical closure to ground, 1 mA
External Control Outputs (4): 50 mA, Open-collector to Ground
Power Requirement: 24 Vdc @ 110 mA, Ground-referenced
Installation/Operation
Declaration of Conformity available from rdlnet.com.
Sole EMC specifications provided on product package.
Specifications are subject to change without notice.
891-3060M
Radio Design Labs Technical Support Centers
U.S.A. (800) 933-1780, (928) 778-3554; Fax: (928) 778-3506
Europe [NH Amsterdam] (++31) 20-6238 983; Fax: (++31) 20-6225-287
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rule. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. The equipment generates,
uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off an
on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment
and receiver
Connect the equipment into an outlet on a circuit
different from that which the receiver is
connected.
Consult the dealer or an experienced radio/TV
technician for hel
p
.

Other RDL Switch manuals

RDL RACK-UP Series User manual

RDL

RDL RACK-UP Series User manual

RDL RACK-UP Series User manual

RDL

RDL RACK-UP Series User manual

RDL EZ Series User manual

RDL

RDL EZ Series User manual

RDL RACK-UP RU-VSX4 User manual

RDL

RDL RACK-UP RU-VSX4 User manual

RDL RACK-UP Series User manual

RDL

RDL RACK-UP Series User manual

RDL ST-SX4 Guide

RDL

RDL ST-SX4 Guide

RDL RACK-UP Series User manual

RDL

RDL RACK-UP Series User manual

Popular Switch manuals by other brands

5Gstore EZ-62B Setup guide

5Gstore

5Gstore EZ-62B Setup guide

WTI RAB-14A user guide

WTI

WTI RAB-14A user guide

Zte ZXR10 1150-5T Instruction guide

Zte

Zte ZXR10 1150-5T Instruction guide

ZyXEL Communications 43222612 user guide

ZyXEL Communications

ZyXEL Communications 43222612 user guide

Renkforce RS2W operating instructions

Renkforce

Renkforce RS2W operating instructions

Cisco MERAKI MS355 Series installation guide

Cisco MERAKI

Cisco MERAKI MS355 Series installation guide

Hubbell SNAPConnect Series installation instructions

Hubbell

Hubbell SNAPConnect Series installation instructions

Niveo NGS 24TP-AV Quick installation guide

Niveo

Niveo NGS 24TP-AV Quick installation guide

NETGEAR MS108EUP Hardware installation guide

NETGEAR

NETGEAR MS108EUP Hardware installation guide

Edimax EK-16RE Quick install guide

Edimax

Edimax EK-16RE Quick install guide

Ubiquiti UniFi USW-Industrial quick start guide

Ubiquiti

Ubiquiti UniFi USW-Industrial quick start guide

KTI KS-2260 operating instructions

KTI

KTI KS-2260 operating instructions

Enterasys Matrix E5 5H153-50-G user guide

Enterasys

Enterasys Matrix E5 5H153-50-G user guide

KinAn XL1808 manual

KinAn

KinAn XL1808 manual

Avaya 8600 Configuration manual

Avaya

Avaya 8600 Configuration manual

Russound A-H484 installation manual

Russound

Russound A-H484 installation manual

Field Controls 46091800 manual

Field Controls

Field Controls 46091800 manual

Apantac CLN-SW-6x1-M user manual

Apantac

Apantac CLN-SW-6x1-M user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.