REED R6020 User manual

reedinstruments
www com
Model R6020
Temperature & Humidity
USB Data Logger
Instruction
Manual
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Shop for Data Logging products online at: www.DataLoggerStore.com 1.877.766.5412

reedinstruments
www com
2
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
• Memoryfor32,000readings(16,000temperatureand16,000humidity
readings)
• Dewpointindication
• Multi-modetostartlogging
• Selectablemeasuringcycle:2s,5s,10s,30s,1m,5m,10m,30m,1hr,
2hr,3hr,6hr,12hr,24hr
• User-selectablealarmthresholdsforbothtemperatureandhumidity
• Statusindicationviared/yellow/greenLEDs
• USBinterfaceforset-upanddatadownload
• Analysissoftware
• Longbatterylife
1.Protectivecover
2.USBconnector
3.Startbutton
4.RH&temperaturesensors
5.AlarmLED(red/yellow)
6.RecordLED(green)
7.Mountingclip
Shop for Data Logging products online at: www.DataLoggerStore.com 1.877.766.5412

reedinstruments
www com
3
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
BothLEDlightsOFF:
LoggingnotactiveOR
LowBattery
Startlogging,replace
batteryanddownload
thedata
Singlegreenashevery
10s*:Logging,noalarm
condition**Doublegreen
ashevery10s*:Delayed
start
Tostart,holdthestart
buttonuntilGreenand
YellowLEDsash
Singleredashevery10s*:
Logging,lowalarmfor
RH***Doubleredash
every10s*:Logging,high
alarmforRH***Singlered
ashevery60s:
Lowbattery****
Loggingwillstop
automatically.Nodata
willbelost.Replace
batteryanddownload
data.
Singleyellowashevery
10s*:Logging,lowalarm
forTEMP***Doubleyellow
ashevery10s*:Logging,
highalarmforTEMP***
Singleyellowashevery
60s:Loggermemoryfull
Downloaddata
Shop for Data Logging products online at: www.DataLoggerStore.com 1.877.766.5412

reedinstruments
www com
4
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
• Tosavepower,thelogger’sLEDashing-cyclecanbechangedto20s
or30sviasoftware.
• Tosavepower,alarmLEDsfortemperatureandhumiditycanbedis-
abledviasoftware.
• Whenbothtemperatureandrelativehumidityreadingsexceedalarm
levelsynchronously,LEDstatusindicationalternateeverycycle.For
example:Ifthereisonlyonealarm,theRECLEDblinksforonecycle
andalarmLEDwillblinkfornextcycle.Iftherearetwoalarms,REC
LEDwillnotblink.Firstalarmwillblinkforrstcycleandthenext
alarmwillblinkfornextcycle.
• Whenthebatteryislow,allrecordingoperationswillbedisabled
automatically.NOTE:Loggingautomaticallystopswhenthebattery
weakens(loggeddatawillberetained).Softwareisrequiredtorestart
recordingandtodownloadloggeddata.
• Tousethedelayfunction.Runthedataloggergraphsoftware,click
onthecomputericon“DataLoggerSetup”orselectfromtheFiledrop
downmenu.TheSetupwindowwillappear,andyouwillseetwoop-
tions:ManualandInstant.IfyouselecttheManualoption,afteryou
clicktheSetupbutton,theloggerwon'tstartloggingimmediatelyuntil
youpresstheYellowstartbutton.
• Whentheloggerisnotinrecordingmode,andmemoryisnotfull,
pressandholdthestartbuttonfor3secondstobeginrecording.
Whentheloggerisinrecordingmode,andmemoryisfull,pressand
holdthestartbuttonfor6secondstostoprecordinganddeletethe
memory(aflashingRedLEDwillconfirmmemoryhasbeenerased.
Shop for Data Logging products online at: www.DataLoggerStore.com 1.877.766.5412

reedinstruments
www com
5
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
LoggingRate: Selectablesamplingintervalfrom2seconds
upto24hours
OperatingTemp: -35to80°Cor-31to176°F
BatteryType: 3.6Vlithium(1/2AA)(SAFTLS14250,
TadiranTL-5101orequivalent)
BatteryLife: 1year(typically)dependingonloggingrate,
ambienttemperatureanduseofalarmLEDs
Dimensions/Weight: 101x25x23mm(4x1x.9”)/172g(6oz)
Relative
Humidity
0to20%&80to100%
20to40%&60to80%
40to60%
±5.0%
±3.5%
±3.0%
Temperature -40to-10°C&+40to+70°C
10to+40°C
-40to+14°F&104to158°F
+14to+104°F
±2°C
±1°C
±3.6°F
±1.8°F
Dewpoint
Temperature
-40to70°C(-40to158°F) ±2.0°C(±4.0°F)
Shop for Data Logging products online at: www.DataLoggerStore.com 1.877.766.5412

reedinstruments
www com
6
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Onlyuse3.6Vlithiumbatteries.Beforereplacingthebattery,removethe
dataloggerfromthePC.Followsteps1through4below:
1.Useapointedobject(eg.asmallscrewdriver)toopenthecasing.
Leverthecasingointhedirectionofthearrow.
2.Pullthedataloggerfromthecasing.
3.Replace/insertthebatteryintothebatterycompartmentobserving
therightpolarity.Thetwodisplaysbrieylightupforcontrolpurposes
(alternatinggreen/yellow/green).
4.Slidethedataloggerbackintothecasinguntilitsnapsintoplace.Now
thedataloggerisreadyforprogramming.
LeavingthemodelpluggedintotheUSBportforlongerthannecessary
willcausesomelossofthebatterycapacity.
Handlelithiumbatteriescarefully,observewarningsonbatterycasing.
Disposeofinaccordancewithlocalregulations.
Shop for Data Logging products online at: www.DataLoggerStore.com 1.877.766.5412

reedinstruments
www com
7
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Shop for Data Logging products online at: www.DataLoggerStore.com 1.877.766.5412
Table of contents
Other REED Data Logger manuals