REED SD-6020 User manual

reedinstruments
www com
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Model
Instruction
Manual
Force Gauge Datalogger
SD-6020

reedinstruments
www com
2
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Table of Contents
Features............................................................................................ 3
Specications................................................................................3-4
Instrument Description ..................................................................... 5
Operating Instructions.................................................................6-10
Alarm Beeper................................................................................. 6
Peak Hold Measurement................................................................ 6
Backlight ON/OFF.......................................................................... 7
Datalogger..................................................................................... 7
Auto Datalogger..........................................................................7-8
Manual Datalogger......................................................................... 8
Peak Hold Datalogger.................................................................8-9
Checking the Time......................................................................... 9
Check Sampling Time Information.................................................. 9
SD Card Data Structure................................................................. 9
Data Transfer from SD card to Computer..................................9-10
Advanced Settings ....................................................................10-12
SD memory card Format ............................................................. 11
Set Clock Time ............................................................................ 11
Set sampling time ........................................................................ 11
Set sampling time (Peak Mode).................................................... 11
Auto power OFF management..................................................... 12
Set Beeper Sound ON/OFF ......................................................... 12
Setting the Decimal point on the SD Card.................................... 12
Set Measurement Unit ................................................................. 12
ESC............................................................................................. 12
PC Serial Interface.......................................................................... 13
System Reset ................................................................................. 14
Battery Replacement...................................................................... 14

reedinstruments
www com
3
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Features
• Data record in Normal Mode or Peak Hold Mode
• Sampling time: Normal Mode: 1sec - 8h; Peak Hold: 10ms - 500ms
• Memory capacity: Normal Mode: 1GB - 16 GB;
Peak Hold: 1000 data no. (max)
• Display units in Kg, lb, Newton
• Tension and compression capability
• Full capacity zero (tare) control capability
• Fast/Slow response time
• Positive or reverse display direction
• Over load protection
• Real time SD memory card datalogger with a built-in clock and
calendar
• No extra software needed, just plug the SD card into the computer
and it downloads directly to EXCEL
• SD card capacity: 1 GB to 16 GB
• Easy to read LCD with backlight
• Auto power off or manual power off
• High accuracy microcomputer circuit
• Power by UM3/AA (1.5 V) x 6 batteries
• USB/RS232 Computer interface
Specifications
Circuit: Custom microprocessor LSI circuit
Display: 52mm x 38mm LCD with backlight
Units: Kg, lb, Newton
Measuring Capacity: 20.00Kg / 44.10lb / 196.12N
Min. Display: 0.01Kg / 001lb / 0.02N
Accuracy: ±(0.5% + 2 digits), within 23±5°C

reedinstruments
www com
4
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Sampling Time: 0.2-0.6 seconds
Auto Sampling Time: 1 second to 9 hours
Peak Hold: 10mS - 500mS
Full Scale Deection: 0.4mm Max
Zero/Tare Control: Max full capacity
Memory Card: SD memory card, 1 GB to 16 GB
Data Output: USB/RS232 PC computer interface
Operating Temperature: 0-50°C (0-122°F)
Operating Humidity: Less than 85% R.H.
Power Supply: UM3/AA (1.5 V) x 6 batteries
Weight: 650g/1.43lb
Dimensions: 215 x 90 x 45mm (8.5 x 3.5 x 1.8")
Includes: Flat-head adapter, Hook adapter, Cone head
adapter, Chisel head adapter, 120mm
extension rod, and one Carrying case
Optional accessories: 2G SD Card (SD-2GB)
Test stand (FS-1001)
Wedge grip (WG-01)
USB cable (USB-01)
Power adapter (AP-9VA-110V)
Data Acquisition Software (SW-U801-WIN)
Visit us at www.reedinstruments.com for more information on our Optional
Accessories, or e-mail us at info@reedinstruments.com
For service on this or any other REED product or information on other

reedinstruments
www com
5
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Instrument Description
1. Sensor
2. Display
3. Power & Backlight Button
4. Up & Zero Button
5. Fast, Slow, & ESC Button
6. Peak & Enter Button
7. Display Reverse
& Down Button
8. Time & Set Button
9. Logger & Sampling
Check Button
10. USB/RS232 Output
11. Reset Button
12. AC/DC 9V Power
Adapter Input Socket
13. Mounting Holes
14. Battery Compartment/Cover
15. Flat-head Adapter
16. Cone Adapter
17. Chisel Adapter
18. Hook Adapter
19. 120 mm Extension Rod
20. SD card slot

reedinstruments
www com
6
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Operating Instructions
When measuring Compression, the meter will show a "-" symbol. While
measuring, be sure to have the Sensor aligned with the object being mea-
sured. Do not measure on an angle, as the Sensor may be damaged and
the readings will not be accurate.
1) Turn on the meter by pressing the Power Button. To turn the meter
off, hold the Power Button for 2 seconds.
2) Select the measuring unit. For instructions on this, please see the
Advanced Settings section.
3) Connect an Adapter and the measuring object to the Sensor. The
measuring object should be in a straight line. Do not apply any
force while in Standby Mode.
4) Zero Adjust the meter by pushing Zero Button before every mea-
surement.
5) Start measuring by giving force (push or pull) to the Sensor. The
screen will display the Average reading value. To change the dis-
play direction, push the Reverse Button.
6) There are two kind sampling time of display, Fast and Slow. The
Display will indicate "FAST" if measuring in Fast Sampling Time,
and "SLOW" if measuring under Slow Sampling Time. Push the
Fast/Slow Button to switch between Fast and Slow Sampling.
Note: Over range of tension will display as " ---- " and over range of
compression will display as "----".
Peak Hold Measurement
The meter can measure the peak value of force both of tension & com-
pression operation. While taking a measurement, as described above,
press the Peak Button to switch to Peak Hold Mode. The Display will
show the "PEAK" indicator, and during measurement the Display will
freeze on the Peak hold value.
Alarm beeper
If the measuring value is over 20.00 Kg, an internal buzzer will sound.

reedinstruments
www com
7
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Backlight ON/OFF
After powering the meter ON, the LCD Backlight will turn on automati-
cally. While taking measurements, press the Backlight Button and the LCD
Backlight will turn off. Press the Backlight Button once again to turn the
LCD Backlight back ON.
Datalogger
Preparation Before Executing the Datalogger Function:
1) Insert the optional SD card into the SD card socket.
2) Before you use an SD card with this meter for the rst time, it is
recommend to format the SD card. See Advanced Settings section
of this manual for instructions.
3) If this is the rst time the meter is used you need to adjust the
clock. See Advanced Settings section of this manual for instruc-
tions.
4) Now you need to set the decimal format. The numerical data struc-
ture downloaded to the SD card is defaulted used the "." as the
decimal, for example "20.6" "1000.53". But in certain countries the
"," is used as the decimal point, for example "20, 6" "1000,53". See
Advanced Settings section of this manual for instructions on how
to change the Decimal Character.
Auto Datalogger (Set sampling time ≥1 second)
1) Start Datalogging; press the REC Button, and the "REC" symbol
will appear on the LCD screen, then press the Logger Button, the
"REC" symbol will ash while the measuring data and time informa-
tion is being saved in memory. To set the sampling time, and to
toggle the beeper sound on or off, refer to the Advanced Settings
section of this manual.
2) Pause the Datalogging; while Datalogging, if press the Logger But-
ton once. While paused, the "REC" symbol will stop ashing. Press
the Logger Button again to resume Datalogging, and the "REC"
symbol will begin to ash again.
continued...

reedinstruments
www com
8
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
3) Stop Datalogging; while the Datalogger function is paused, press
the REC Button for 2 seconds. The "REC" symbol will disappear
indicating the Datalogging function has stopped.
Manual Datalogger (Set sampling time = 0 seconds)
1) Set sampling time is to 0 second; Press the REC Button, and the
"REC" symbol will appear on the LCD screen. Press the Logger
Button, and the "REC" symbol will ash once and one Beep will
sound, at the same time the measuring data along the time infor-
mation will be saved in memory. The lower Display will show the
Position (record) number, which is saved as well.
2) To Change the Position Number; press the Down Button and the
lower position number will ash on the display. Press the Up or
Down Buttons to set the Position Number (1 to 99) to help identify
the measurement location. The lower Display will show P x (x = 1 to
99). After the position number is selected, press the Enter Button to
conrm.
3) Stop Datalogging; press the REC Button for 2 seconds, and the
"REC" symbol will disappear indicating the Datalogging function
has stopped.
Peak Hold Datalogger
1) Install the meter on to the optional test stand and turn on the meter.
2) Press the Peak Button and the Display will show "PEAK" & "FAST".
3) Press the Zero Button to set the Zero Value.
4) Press the Logger Button and the screen will display "DATA
RECORD" while the sampling time value in ms will appear on
the bottom of the screen. The meter is now ready for Peak Hold
Datalogging.
5) If the applied force value is > 0.2 Kg (1% full capacity), the
measurement value and sampling period will save to the internal
memory circuit in sequence. To change the Sampling Time, please
see the Advanced Settings section of this manual.
continued...

reedinstruments
www com
9
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
6) When the peak value is obtained, the indicator "DATA RECORD"
will disappear, while the "PEAK" indicator and the Peak Value will
remain. The bottom of the Display will show the data record num-
ber and count down to zero, while saving the data to the SD card.
Checking the Time
During normal functions (not Datalogging), press the Time Check Button
and the lower LCD display will show the Year, Month/Date, Hour/Minute.
Check Sampling Time Information
During normal functions (not Datalogging), press the Sampling Button and
the lower LCD display will show the Sampling Time Information.
SD Card Data Structure
1) The rst time the SD card is used in the meter, the SD card will
generate a folder: FGB01
2) The rst time you use the Datalogger, in the folder FGB01, a new
le name FGB01001.XLS will be created. The Datalogger will use
this le until the Data has reached to 30,000 rows. The meter will
then will generate a new le with a subsequent number, for ex-
ample FGB01002.XLS.
3) The folder FGB01 can hold 99.XLS les. When that number has
been reached, the meter will then will generate a new folder with
a subsequent number, for example FGB02. Max number of FGB--
folders is 10.
Data Transfer from SD card to Computer (EXCEL Software)
1) After Datalogging, remove the SD card from the SD card slot.
2) Plug in the SD card into the Computer’s SD card slot or insert the
SD card into the optional SD card adapter and connect to your
Computer. Turn your computer on and a folder will appear on your
desktop representing you SD card.
continued...

reedinstruments
www com
10
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
3) Open "Microsoft EXCEL". Download the EXCEL les from the SD
Card to the computer by opening up the SD folder and selecting
the desired EXCEL les, and drag-and-drop them onto your Com-
puter. Open the les with EXCEL (File – Open).
4) The EXCEL le will have the following column headers in this order:
Place (Position Number), Date (Year/Month/Day), Time (in 24h
clock), Value, and Unit.
Advanced Settings
During normal functions (not Datalogging), press and hold the SET Button
for 2 seconds to enter the "Advanced Setting" mode. Press the Next But-
ton scroll through eight main functions, shown on the lower display:
Sd F SD memory card Format
dAtE Set clock time (Year/Month/Date, Hour/Minute/Second)
SP-t Set sampling time (Hour/Minute/Second)
HSPt Set sampling time for peak record mode
PoFF Auto power OFF management
bEEP Set beeper sound ON/OFF
unit Set the measurement unit
dEC Set SD card Decimal character
ESC Exit Advanced Settings
While in the "Advanced Setting" function, press the Esc Button to exit and
to return to normal functioning.
SD memory card Format
Please Note: Formatting the SD card erases all data from that SD card.
1) When the lower display shows "Sd F", use the Up or Down Buttons
to select "yES" (format the SD card) or "no" (do not format the SD
card).
2) To format your SD card, select "yES" and press the Enter Button.
The Display will show "yES Enter", to conrm. Press the Enter But-
ton to conrm.

reedinstruments
www com
11
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Set Clock Time
1) When the lower display shows "dAtE", press the Enter Button.
Use the Up and Down Buttons to adjust the Year. After the desired
value is set, press the Enter Button to adjust the Month, Date, Hour,
Minute, and Second values.
2) After all the time values have been set the screen will jump to "SD
card Decimal character" setting screen. To exit "Advanced Set-
tings", press the Esc Button.
Note: After the time value is set, the internal clock will run even when
the power is off, if the battery is under normal conditions.
Set sampling time
1) When the lower display shows "SP-t", use the Up or Down Buttons
to adjust the value to either 0, 1, 2, 5, 10, 30,60, 120, 300, 600,
1800, or 3600 seconds.
2) After the Sampling value is selected, press the press the Enter But-
ton to save the setting as the default. To exit "Advanced Settings",
press the Esc Button.
Set sampling time (Peak Mode)
1) When the lower display shows "HSPt", use the Up or Down But-
tons to adjust the Sampling Time value between 10mS and 500mS.
2) After the Sampling value is selected, press the press the Set Button
to save the setting. To exit "Advanced Settings", press the Esc But-
ton.
Auto power OFF management
1) When the lower display shows "PoFF", use the Up or Down But-
tons to select the value "yES" (Enable Auto Power Off) or "no"
(Disable Auto Power Off.
2) After selecting "yES" or "no", press the Enter Button to save the
setting as the default. To exit "Advanced Settings", press the Esc
Button.

reedinstruments
www com
12
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Set Beeper Sound ON/OFF
1) When the lower display shows "bEEP", use the Up or Down But-
tons to select "yES" (Beeper Sound is ON) or "no" (Beeper Sound
is OFF).
2) After selecting "yES" or "no", press the Enter Button to save the
setting as the default. To exit "Advanced Settings", press the Esc
Button.
Setting the Decimal point on the SD Card
1) When the lower display shows "dEC", use the Up or Down Buttons
to toggle between "bASIC" ("." Decimal Point) or "Euro" ("," Deci-
mal Point).
2) After the Decimal point character has been selected, press the
Enter Button to save the setting as the default. To exit "Advanced
Settings", press the Esc Button.
Set Measurement Unit
1) When the lower display shows "unit", use the Up or Down Buttons
to adjust the measurement unit, Kg, lb, or N.
2) After the Measuring Unit is selected, press the press the Enter But-
ton to save the setting. To exit "Advanced Settings", press the Esc
Button.
ESC
When the lower display shows "ESC", press the Enter Button to nish
the Advanced Settings procedures and return to the normal measuring
screen.

reedinstruments
www com
13
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
PC Serial Interface
The instrument features an PC output via 3.5 mm terminal. The connector
output is a 16 digit data stream which can be utilized to the user’s specic
application. An USB RS232 lead with the following connection will be
required to link the instrument with the PC serial input.
Meter (3.5mm Jack Plug) PC (9W "D" Connector)
Center Pin Pin 2
Ground/Shield Pin 5
The 16 digit data stream will be displayed in the following format:
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
D0 End Word
D1 to D4 Upper Display reading, D1= LSD, D4= MSB
D5 to D8 D5=? D6=? D7=? D8=?
D9 Decimal Point ( DP) for display
0 = No DP, 1 = 1 DP, 2 = 2 DP, 3 = 3 DP
D10 D10 = 0
D11 D11 = 0
D12 D12 = 0
D13 D13 = 0
D14 D14 = 0
D15 Start Word

reedinstruments
www com
14
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
System Reset
If an error occurs, press the Reset Button with a Pin. If the Reset Button
does not x the error, please send in the unit to our Calibration Lab for
repair. E-mail info@reedinstruments.com for more information.
Battery Replacement
1) When the left corner of LCD display shows , it is necessary to
replace the battery
2) Loosen the screws of the Battery Cover and remove
3) Remove the batteries and replace with Six DC 1.5 V batteries
(UM3, AA, Alkaline/heavy duty)
4) Make sure the battery cover is properly secured after changing the
battery
For service on this or any other REED product or information on other

reedinstruments
www com
15
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________

reedinstruments
www com
16
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
INSTRUMENTS
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
Table of contents
Other REED Data Logger manuals
Popular Data Logger manuals by other brands

ELPRO
ELPRO ECOLOG-NET LP4 Operation manual

Dickson
Dickson VFC320 Web manual

Wavetronix
Wavetronix Click 514 Installation & quick start guide

Extech Instruments
Extech Instruments RHT30 user manual

socomec
socomec DATALOG H80 quick start guide

IRROMETER
IRROMETER WaterGraph Data Shuttle Installation and operating instructions