4 | F3500 Wood Stove
Pedestal
Bolted to
Floor
Permanent Outside
Air Inlet
MOBILE HOME INSTALLATION
Once you have properly marked the position of
your unit and the oor protection as outlined in
the Residential Installation items #1 through #8, a
supply of fresh air has to be supplied to your unit.
See Optional Outside Air Kit instructions in this
manual.
Place your unit in position and secure it to the
oor using two lag bolts 3/8" (10mm) x 3-1/2"
(89mm) through the two holes inside the pedestal
base. It is important to maintain the structural
integrity of the Mobile Home oor, walls and roof
when installing your unit.
For Mobile Home units installed in the U.S. the
unit must be grounded using a #8 ground wire
with approved termination and star washer.
In addition to standard installation
instructions the following requirements are
mandatory for installation in a mobile home.
1. The stove must be permanently bolted to
the oor of the Mobile Home using the
oor screws provided.
2. The stove must have a permanent outside
air source for combustion.
3. The stove must be electrically grounded
to the steel chassis of the Mobile Home.
4. A listed double-wall connector chimney
system, roof thimble, spark arrestor and
roof ashing kit suitable for use in Mobile
Homes must be used.
5. If the chimney exits the Mobile Home at
a location other than through the roof,
and exits at a point 7ft. (2130mm) or
less above the ground level on which
the Mobile Home is positioned a guard
or method of enclosing the chimney shall
be tted at the point of exit for a height
up to 7ft. (2130mm).
6. The chimney shall be attached directly
to the room heater and shall extend at
least 3 ft. (914mm) above the part of the
roof through which it passes. The top of
the chimney should project at least 2ft.
(610mm) above the highest elevation of
any part of the Mobile Home within 10
ft. (3048mm) of the chimney.
7. The chimney system shall comply with
Local Requirements.
8. Any openings in a chimney guard where
required must not permit the entrance
of 3/4" (19mm) diameter rod.
9. CAUTION: THE STRUCTURAL
INTEGRITY OF THE MOBILE HOME
ROOF, FLOOR, WALLS AND CEILING
MUST BE MAINTAINED.
10. Check any other local building code as
other local codes may apply.
11. WARNING: DO NOT INSTALL IN
A SLEEPING ROOM OF A MOBILE
HOME.
12. Use silicone to create an eective vapour
barrier at the location where the chimney
or other component penetrates to the
exterior of the structure.
CAUTION: At no time use unlabelled
parts, or substitute parts made for
another chimney system.
Install as per chimney manufacturer's
installation instructions.
For Canadian Installations: see Outside
Air Kit Blanking Plate - Part # 042-909
There are further requirements when installing
this unit into a mobile home in Canada Only.
WARNING: Operate only with door
fully closed - open feed door to feed
re only.
1. Identify the position of the outside air damper by the orientation of the metal handle that rests
outside the galvanized pipe. The metal handle and the damper disc are in line with each other.
This means that if the metal handle is in a horizontal position, the damper is at and fully open.
2. Open the damper fully whenever you start a re. This will allow the outside air to be drawn in
the pedestal base eliminating any potential smoke escaping the stove and entering the room.
(Negative air pressure)