Regent Control Systems BC-9461 User manual

OPERATING MANUAL
LENGTH COUNTER
BC 9461/7461
Helpline : +91 9624004123
R
REGENT CONTROL SYSTEMS
BC 9461
BATCH COUNT
1 2 3 4 5 .6
1 2 3 .4
SET
ENT RESET
R
BC 7461
1 2 3 4 5 .6
1 2 3 .4
SET
ENT RESET
Page - 1
Proximity PNP/NPN (Selectable) & Micro Switch
Nonvolatile
Power Supply
Protection Level
Operating
Relative
(As per request)
Temperature
Humidity
230V AC, 50 Hz, Approx 4VA
IP-65(Front side) AS per IS/IEC 60529:2001
0°C To 55°C
Up to 95% RH Non Condensing
Model
Display
Size(HXWXD)
Panel Cutout
Output
Sensor
Memory
BC-9461
96 X 96 X 45 mm
92 X 92 mm 68 X 68 mm
72 X 72 X 60 mm
UPPER:- 6 Digit 7 seg 0.56”,
red LED Display
UPPER:- 6 Digit 7 seg 0.4”,
red LED Display
LOWER:- 4 Digit 7 seg 0.4”,
green LED Display
LOWER:- 4 Digit 7 seg 0.4”,
green LED Display
BC-7461
1 Relay, 1C/O,230V AC,5A
Technical Specification
Connection Diagram
MADE IN INDIA
TOTAL
TOTAL
BATCH COUNT
Note:
1. For NPN Proxi Short pin 3 & 4
2. For PNP Proxi Short pin 6 & 5
3. For Microswitch Short pin 6 & 5
Proxi Connction to 4,6,5
Proxi Connction to 3,4,5
Micro switch Connection to 3 & 4
7 8 9 10
56
LN
1234
230V AC
50Hz, 4VA
RST
NCCNO
RELAY
MICRO SWITCH:- M/S Connection 7 & 9
+12V
I/P I/P
NPN PNP GND
!
12 11
BUZZER
-
+
15
18
16
19
17
20
BUZZER
-
+
230V AC
50Hz,4VA
NC
I/P
NPN
+12V
I/P
PNP
GND
NO
C
L
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
!
RESET
MICRO SWITCH:-
M/S Connection 9 & 11
BC 9461 BC 7461
CARE
R
REGENT CONTROL SYSTEMS (I) PVT LTD
MADE IN INDIA
CARE
R
REGENT CONTROL SYSTEMS (I) PVT LTD
MADE IN INDIA
REGENT CONTROL SYSTEMS (I) PVT LTD. REGENT CONTROL SYSTEMS (I) PVT LTD.

Helpline : +91 9624004123
Page - 2
Key Operation
1) Press Key to go next
parameter.
2) Release the Key, to save
the set point.
3) Press Key for manual reset
of total length
SETSET
SET
MADE IN INDIA
Total Batch Count
Batch Count
Press Key
Press Key
For Program :
Press Key
Press Key
Total Batch Count
Batch Count
Press Key To save & exit
Press Key To save & exit
For Program :
Ch -1
1 2 3 4 5 6
1 2 3 4
9 9 9 9
9 9. 9 9
Ch -2
1 2 3 4 5 6
1 2 3 4
9 9 9 9
9 9 9 9
s e t c t 1
r l y t I m
s e t c t 1
s e t c t 2

Helpline : +91 9624004123
Page - 3
Working
MADE IN INDIA
* When set Count reaches at set value ,Relay and Buzzer will be ON.
* Relay will stay on up to the set Time.
* After completion of the set Time - both ,Relay and Buzzer will be OFF.
* If the set time is . then Instrument will work in manual mode and
user need to press Reset key to turn OFF Relay & Buzzer.
Set Count - 1: Advance setting for batch Count.
Set Count - 2: Batch setting.
Always set the value of set 1 less then set 2.
When it reaches to set count 1, Relay & Buzzer will be ON, & when it reaches
to set count 2, Relay Buzzer will be OFF & Batch Count will be zero.
Note:
Press key and power on the instrument Display will show parameters
‘SLOW’.”MEDIUM” & “FAST”
Set Speed Selection by Pressing key
SLOW : MAX RPM 500
MEDIUM : MAX RPM 5000
FAST: MAX RPM 15000
Press key to save the parameters
:
Ch -1
:
Ch -2
S p e e d
m d u m
Press Key
for 15 sec.
Press Key To save & exit
Change
Channel
by Pressing
Key
Procedure to set channel of program
1 2 3 4 5 6
1 2 3 4
p ro 9 r a
c h - 1 c h - 2
p ro 9 r a

Helpline : +91 9624004123
Page - 4
R
BC 9461
0 1 2 3 4 .5
0 1 2 3
All safety related codifications, symbols and instructions that appear in this operating manual
or on the equipment must be strictly followed to ensure the safety of the operating personnel as
well as the instrument.
If all the equipment is not handled in a manner specified by the manufacturer, it might impair the
protection provided by the equipment .
=> Read complete instructions prior to installation and operation of the unit.
WARNING : Risk of electric shock.
3) Cable used for connection to power source, must have a cross section of 1mm or greater. These wires
should have insulations capacity made of at least 1.5kV.
2) To reduce electro magnetic interference, use wire with adequate rating and twists of the same of equal size shall
be made with shortest connection.
1) To prevent the risk of electric shock power supply to the equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is being supplied.
4) A better anti-noise effect can be expected by using standard power supply cable for the instrument.
1) This equipment, being built-in-type, normally becomes a part of main control panel and such in case the
terminals do not remain accessible to the end user after installation and internal wiring.
2) Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product
or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.
3) Circuit breaker or mains switch must be installed between power source and supply terminal to
facilitate power ‘ON’ or ‘OFF’ function. However this mains switch or circuit breaker must be
installed at convenient place normally accessible to the operator.
4) Use and store the instrument within the specified ambient temperature and humidity ranges as
mentioned in this manual.
Warning Guidelines
Safety Precautions
Installation Guidelines
Mechanical Installation
Maintenance
1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source,
caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals.
1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.
2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any other cleaning agent.
3) Fusible resistor must not be replaced by operator.
2
95mm - 3.75 inches
85mm - 3.34 inches
136mm - 5.35 inches
120mm - 4.72 inches
B
B
A
A
F
E
MODEL A
96mm 96mm 92mm 92mm 3mm 42mm
BC
D E
F
DIMENSIONS
MODEL A
72mm 72mm 68mm 68mm 3mm 57mm
BC
D E
F
DIMENSIONS
C
C
D
D
R
BC 7461
12345.6
1 2 3 .4
SET
SET
ENT
ENT
RESET
RESET
EF
MADE IN INDIA
REGENT CONTROL SYSTEMS (I) PVT LTD.
REGENT CONTROL SYSTEMS (I) PVT LTD.
BATCH COUNT
TOTAL
BATCH COUNT
TOTAL