Parameter MODE
press key
o n u s
- - -
press key
f r d
9 9 9 9
r e v
9 9 9 9
press key to
set Password
h o l d
9 9 9 9
press key
press key to
Working
1), Turn ON instrument. SET time according to your requirement.
2). In running mode, upper display indicates current TIME value and lower display shows SET
time value. Relay ON controls depends on set time.
3). Relay operation is according to ON delay mode.
4) To start the timer press start pulse Key. forward time and reverse time run after hold time according
to set by user. After reaching the total time the buzzer will on.
MODEL A
72mm 72mm 44mm 66mm 3mm 85mm
BC
D E
F
DIMENSIONS
Mechanical Installation
1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source,
caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals.
F
E
C
D
B
A
REGENT CONTROL SYSTEMS (I) Pvt Ltd
R2
TIME
SET TIME
press key to
set Reverse time, range :- 0 -9999 sec.
t o t i
9 9 9 9
press key
press key to set total time
range :- 0 -9999 min.
press key to save and Exit
press key to
set HOLD time, range :- 0 -9999 sec.