1. INTRODUCTION
BIO 55 MIX W–PWM 1F TRS6K Load Unit includes a complete hydraulic and electrical
connections for the installation of a heating system with a solid fuel boiler.
The load unit has a complete electrical installation and is tted with a power cord with a plug.
All you need to do is connect the boiler, the heating system, the thermal store with DHW,
then place the sensors and plug the load unit into a socket. Then select the corresponding
hydraulic variant in the controller using the setup wizard and set other required parameters.
It is possible to connect the Caleon room unit with colour touch screen and easy operation to
the controller. Room unit is not included, shall be ordered separately.
2. DESCRIPTION
Main Features
Description The Load Unit includes:
● TRS6 BIOMIX controller with hydraulic variant selection for smart
control of the entire system
● two Wilo Para 25/8 iPWM1 circulation pumps with continuous
performance control via PWM signal for boiler circuit and heating
system
● TSV3BM load valve with automatic bypass balancing to protect
the boiler against low temperature corrosion by keeping return water
temperature at 55 °C minimum
● motorised three-way mixing valve including actuator to maintain the
required temperature in the heating circuit
● two ball valves and a drain valve for shutting off and draining the
heating system
● check valve integrated in the ball valve body located at the outlet
from the heating system
● two ball valves and a drain valve to shut off the boiler circuit
● two ball valves permitting to shut off the thermal store circuit
(included in supply)
● lever for ball valves
● 3m power cord, 1.5 mm2cable cross section
● Pt 1000 outdoor temperature sensor with 10 m cable
● four Pt 1000 temperature sensors with 4 m cable
● four thermometers
● outlets to connect a thermal store or a combination one and
alternative outlets to connect optional accessories
Working uid water, antifreeze uid for heating systems
Installation vertically on a wall using the installation kit
Connections 2 x G 1“ F to connect a heating system
2 x G 1“ F to connect a boiler circuit
2 x G 1“ F to connect a thermal store
2 x G 1/2“ F alternative outlets to connect optional accessories (if you
do not need to use the outputs, they can be plugged with the enclosed
plugs)
Code 17499