Reliable 300 Series User manual

Series 300 Digital Weight Indicators
Printed in Canada
Copyright © 2021, Reliable Scale Corporation
Reliable Scale Corporation
#6 - 1480 28 Street NE
Calgary, AB T2A 7W6
Canada
Tel: 403-272-8784
Toll Free: 800-419-1189
Fax: 403-273-9818
Email: info@reliablescale.com
Web: www.reliablescale.com
User Manual
For version x.33.19

Series 300 User ManualI
Copyright © 2021, Reliable Scale Corporation
Table of Contents
Part I General 1
................................................................................................................................... 11 Front Face Detail
................................................................................................................................... 22 Keypad
................................................................................................................................... 33 StatusIndicators
................................................................................................................................... 44 Model Variations
Part II Basic Operation 7
................................................................................................................................... 71 Turning the 300 SeriesWeight Indicator On
................................................................................................................................... 72 Fine Zero Adjustment
................................................................................................................................... 83 Toggle between weighing units
................................................................................................................................... 84 Manual Hold/Print/Save Weight Records
................................................................................................................................... 105 Auto-Hold Stable Weight Detection
................................................................................................................................... 126 Turning the 300 Series Indicator Off
Part III Configuration Menus 13
................................................................................................................................... 141 Report Menu
.......................................................................................................................................................... 15
Record Totals
.......................................................................................................................................................... 17
Basic Report
.......................................................................................................................................................... 19
Detailed Report
.......................................................................................................................................................... 21
Set Current Lot
.......................................................................................................................................................... 21
Clear Current Lot
.......................................................................................................................................................... 22
Clear All Records
.......................................................................................................................................................... 23
Free Records
.......................................................................................................................................................... 24
RFID Configuration
......................................................................................................................................................... 25
RFID Format
......................................................................................................................................................... 26
RFID Port
......................................................................................................................................................... 26
RFID Display Length
......................................................................................................................................................... 27
RFID Display Speed
................................................................................................................................... 282 User Interface Menu
.......................................................................................................................................................... 29
Time of Day Clock
......................................................................................................................................................... 30
Current Time & Date
......................................................................................................................................................... 31
Set Time......................................................................................................................................................... 31
Set Date.......................................................................................................................................................... 32
Serial Ports......................................................................................................................................................... 33
Output Format
......................................................................................................................................................... 34
Baud Rate
......................................................................................................................................................... 35
Line Delay
......................................................................................................................................................... 35
Accessory Power
.......................................................................................................................................................... 36
Bluetooth ......................................................................................................................................................... 37
Module Operating Mode
......................................................................................................................................................... 39
Port Pass-Through
......................................................................................................................................................... 39
Module Pairing
......................................................................................................................................................... 41
Module Configuration Port
......................................................................................................................................................... 42
Module PIN Code
.......................................................................................................................................................... 43
Count By

IIContents
II
Copyright © 2021, Reliable Scale Corporation
.......................................................................................................................................................... 44
Decimal Places
.......................................................................................................................................................... 44
Backlight Auto-Off
.......................................................................................................................................................... 45
Inactivity Auto-Off
.......................................................................................................................................................... 46
Power Switch Bypass
.......................................................................................................................................................... 47
Remote Interface Port
.......................................................................................................................................................... 48
Remote Address
................................................................................................................................... 483 Auto-Hold Menu
.......................................................................................................................................................... 50
Activate .......................................................................................................................................................... 51
Stability Factor
.......................................................................................................................................................... 52
Sensitivity Factor
.......................................................................................................................................................... 52
Low Weight Limit
.......................................................................................................................................................... 53
High Weight Limit
.......................................................................................................................................................... 54
Tracking Compliance
.......................................................................................................................................................... 54
Lock Compliance
.......................................................................................................................................................... 55
Remote Hold Break
.......................................................................................................................................................... 56
Hold Button
.......................................................................................................................................................... 56
Lock Report
.......................................................................................................................................................... 57
Lock Report Prefix
.......................................................................................................................................................... 58
Auto-Save .......................................................................................................................................................... 58
Reset Level
................................................................................................................................... 594 System Setup Menu
.......................................................................................................................................................... 61
Adjust Calibration Factor
.......................................................................................................................................................... 63
Manual Hold Period
.......................................................................................................................................................... 63
Averaged Display Samples
.......................................................................................................................................................... 64
Averaged Auto-Hold Samples
.......................................................................................................................................................... 65
Factory Calibration
.......................................................................................................................................................... 65
Amplfier Zero Offset Adjustment
.......................................................................................................................................................... 66
Load Cell Input Range
.......................................................................................................................................................... 66
Auto-Calibration
.......................................................................................................................................................... 67
Zero Tracking
.......................................................................................................................................................... 68
System Report
Part IV Error Messages 69
Part V Connector Details 71
................................................................................................................................... 711 Power Connector
................................................................................................................................... 712 Load Cell Connectors
................................................................................................................................... 733 Serial Port Connectors
Part VI Serial Port Output Formats 74
Part VII Specifications 76
Part VIII Limited Warranty 79
Index 0

Series 300 User Manual1
Copyright © 2021, Reliable Scale Corporation
1 General
The 300 Series are general purpose digital weight indicators designed to operate
with standard Wheatstone bridge load cells. They have additionalfeatures that
make them well suited to industrial applications or live animal weighing, including
an average and hold feature that can be triggered manually or automatically. The
300 Series can be equipped with optional features to collect and store RFID tags
when connected to a compatible RFID reader by cable or Bluetooth connection.
1.1 Front Face Detail

General 2
Copyright © 2021, Reliable Scale Corporation
1.2 Keypad
The keys on the 300 Series have different functions depending on the current
operating mode.
In the Normal Operating mode, the upper label indicates the key function. In the
Configuration mode, the lower label indicates its function.
Normal Operating mode
Fine Zero sets the display to zero.
0
Configuration mode
Scrolls upwards through menus and adjusts parameters
upwards.
Normal Operating mode
Enters Configuration mode.
MENU
Configuration mode
Scrolls downwards through menus and adjusts
parameters downwards.
Normal Operating mode
Initiates a Manual Hold operation.
HOLD
ENTER
Configuration mode
Enters sub-menus and accepts/saves parameter
changes.
Normal Operating mode
Toggles between Weighing Units.
EXIT
lb/kg

Series 300 User Manual3
Copyright © 2021, Reliable Scale Corporation
Configuration mode
Exits sub-menus and cancels/discards parameter
changes.
Normal Operating mode
Toggles power On & Off
OFF
ON
1.3 Status Indicators
In the Normal Operating mode, the status indicators show the current state of the
device. When the device is waiting for user input, all status indicators will flash.
Status Indicator
Behavior
KG
On when operating in kilograms
Flashes once when a key is pressed while operating in
kilograms
Flashes once when a Zero Tracking event occurs while
operating in pounds
LB
On when operating in pounds
Flashes once when a key is pressed while operating in pounds
Flashes once when a Zero Tracking event occurs while
operating in kilograms
HOLD
Flashes continuously while a locked/stable weight is displayed

General 4
Copyright © 2021, Reliable Scale Corporation
1.4 Model Variations
Model
300LG
Model
300ILG
Model
300LGX-2
Model
300LGX-
2W
Model 350
Model 350-
2W
Display
LCD
6 Digits x
1" (14 Seg)
6 Digits x
1" (14 Seg)
6 Digits x
1" (14 Seg)
6 Digits x
1" (14 Seg)
6 Digits x
1" (14 Seg)
6 Digits x
1" (14 Seg)
Backlight
Interface
Ports
Serial Port
1
RS-232
RS-232
RS-232
RS-232
Serial Port
2
RS-232 or
RS-485
RS-232 or
RS-485
Bluetooth
SPP
Bluetooth
SPP
Analog
Output
4-20mA / 0-
5VDC
Remote
Communic
ation*
Optional
Serial Port
Req'd
Weight
Records
Storage
Capacity
1,600
1,600
3,200
3,200
1,600
1,600
Record
Content
Weight
Weight
Weight, Date
& Time,
RFID**
Weight, Date
& Time,
RFID**
Weight
Weight
Unique
Lots***
20
20
20
20
20
20
Min/Max/A
verage (by
lot)
Weighing
Operatio
n
Increments
1,2,5,10
1,2,5,10
1,2,5,10
1,2,5,10
1,2,5,10
1,2,5,10
Decimal
Points
Any Position
Any Position
Any Position
Any Position
Any Position
Any Position
Weighing
Units
lb, kg
lb, kg
lb, kg
lb, kg
lb, kg
lb, kg
Zero
Tracking

Series 300 User Manual5
Copyright © 2021, Reliable Scale Corporation
Model
300LG
Model
300ILG
Model
300LGX-2
Model
300LGX-
2W
Model 350
Model 350-
2W
Average &
Hold
Auto &
Manual
Manual
Auto &
Manual
Auto &
Manual
Auto &
Manual
Auto &
Manual
Weight
Triggered
Alarm
Gross/Net/
Tare
Field
Adjustable
Calibration
Auto-
Calibrate**
**
General
Supply
Voltage***
**
12-24VDC
12-24VDC
12-24VDC
12-24VDC
12-24VDC
12-24VDC
Supply
Current (1
Load Cell)
150mA
150mA
150mA
150mA
100mA
100mA
Load Cell
Excitation
(VDC)
7.5
7.5
7.5
7.5
7.5
7.5
Load Cell
Capacity
(350Ω)
Up to 6
Up to 6
Up to 6
Up to 6
Up to 6
Up to 6
Operating
Temp.
-5°F to 140°
F /
-20°C to 60°
C
-5°F to 140°
F /
-20°C to 60°
C
-5°F to 140°
F /
-20°C to 60°
C
-5°F to 140°
F /
-20°C to 60°
C
-5°F to 140°
F /
-20°C to 60°
C
-5°F to 140°
F /
-20°C to 60°
C
Overall
Case
Dimensions
(WxHxD)
10" x 7" x
3.75" /
25.4cm x
17.8cm x
9.5cm
10" x 7" x
3.75" /
25.4cm x
17.8cm x
9.5cm
10" x 7" x
3.75" /
25.4cm x
17.8cm x
9.5cm
10" x 7" x
3.75" /
25.4cm x
17.8cm x
9.5cm
9.5" x 8.5" x
5" /
24.1cm x
21.6cm x
12.7cm
9.5" x 8.5" x
5" /
24.1cm x
21.6cm x
12.7cm

General 6
Copyright © 2021, Reliable Scale Corporation
Model
300LG
Model
300ILG
Model
300LGX-2
Model
300LGX-
2W
Model 350
Model 350-
2W
* Remote Communication allows controland interfacing to an external PC or similar device.
** RF Identification (RFID) operation has been verified with many industry standard devices.
***Lots are used to group weight records, e.g. by pen, truckload, etc.
****Auto-Calibrate feature requires compatible load cells from Reliable Scale Corporation.
*****115vac to 12VDC adapter included as standard; battery clips or cigarette lighter adapter
available as options.
Specifications subject to change without notice.

Series 300 User Manual7
Copyright © 2021, Reliable Scale Corporation
2 Basic Operation
2.1 Turning the 300 Series Weight Indicator On
When turned on, the 300 Series always starts operating in the Normal Operating
mode.
1. Press the ON key.
The model and version number
are displayed, followed by a
display test sequence.
2. Allow a moment for the display to
stabilize.
2.2 Fine Zero Adjustment
If the scale has no weight on it and the display does not show “0”.
1. From the Normal Operating
mode, press the FINE ZERO key.
2. The new zero point is calculated.
3. Display shows “0” and returns to
the Normal Operating mode.

Basic Operation 8
Copyright © 2021, Reliable Scale Corporation
2.3 Toggle between weighing units
The 300 Series can display weights in either pounds (lb) or kilograms (kg). When
working in either unit, the 300 Series will display, accept input and output weights
in that unit exclusively. Weights saved in either unit and later recalled for display
or output by the serial port will be done in the current units, any necessary
conversion is automatic.
1. From the Normal Operating mode
press the LB/KG key.
kg lb
The current units are changed.
kg lb
2.4 Manual Hold/Print/Save Weight Records
The 300 Series can store Weight Records and the record storage process is
initiated by either the Manual or Automatic Hold operations.
The Manual Hold operation is triggered by pressing the HOLD button. Once the
Manual Hold operation has been initiated, an average weight is calculated over a
period of time determined by the Manual Hold Period parameter. Once
calculated, the averaged weight will be shown on the display. At this point it can
be saved or discarded. When saved, it can also be directed to a serial port for
output to a computer or printer.
Note: There is also an Automatic Hold feature available
Note: The Manual Hold feature trigger can be disabled with the Hold Button
parameter in the Auto Hold menu.
1. From the Normal Operating mode
and with an active load on the
scale, press the HOLD key.
During hold averaging period,
HOLD is displayed.

Series 300 User Manual9
Copyright © 2021, Reliable Scale Corporation
Once the averaging period has
elapsed, the averaged weight is
displayed and the HOLD status
indicator flashes rapidly.
Any activity on the scale is
ignored and the weight can be
removed without affecting the
display.
HOLD
2a. To save the weight record, press
the ENTER key.
2b. For RFID models with RFID
collection enabled and no ID
number queued, the ID? prompt
is displayed.
Scan an RFID tag, or press
ENTER to save weight record
without an associated ID.
Press EXIT to cancel the save
operation.
If an ID has been collected, it will
be displayed according to the
RFID Display Length parameter.
2c. To discard the weight record,
press the EXIT key.
3. Display returns to the Normal
Operating mode and displays the
current weight. The HOLD
indicator stops flashing.

Basic Operation 10
Copyright © 2021, Reliable Scale Corporation
2.5 Auto-Hold Stable Weight Detection
The 300 Series can store Weight Records and the record storage process is
initiated by either the Manual or Auto-Hold operations. The Auto-Hold feature is
controlled by a number of parameters in the Auto-Hold menu.
The Auto-Hold operation is triggered when a measured weight is in range. Once a
sufficient number weight readings have been collected and a valid average has
been calculated, the averaged weight will be locked on the display. If sufficient
change in the weight occurs, the lock will be released and the 300 Series will
attempt to reacquire a valid average and lock condition. A locked weight can be
saved. When saved, it can also be directed to a serial port for output to a
computer or printer.
Note: There is also an Manual Hold feature available
Note: The Auto-Hold feature trigger can be disabled with the Activate parameter
in the Auto Hold menu.
1. From the Normal Operating
mode, when an in-range load is
placed on the scale, the Auto-
Hold process begins. Once a
valid average has been calculated,
the averaged weight is locked on
the display and the HOLD status
indicator flashes rapidly.
Sufficient activity on the scale (or
the EXIT key) can cause the lock
to be released.
HOLD

Series 300 User Manual11
Copyright © 2021, Reliable Scale Corporation
2a. For RFID models with RFID
collection enabled and no ID
number queued, The ID? prompt
is displayed.
Scan an RFID tag, or press
ENTER to save weight record
without an associated ID.
Press EXIT to cancel the save
operation.
2b. To save the weight record, press
the ENTER key.
If an ID has been collected, it will
be displayed according to the
RFID Display Length parameter.
2c. To discard the weight record,
press the EXIT key.
3. Display returns to the Normal
Operating mode and displays the
current weight. The HOLD
indicator stops flashing.

Basic Operation 12
Copyright © 2021, Reliable Scale Corporation
2.6 Turning the 300 Series Indicator Off
Note: Do not disconnect the power supplyto turnthe 300 Series off. Use the OFF key.
Important status informationis saved inmemorywhenthe 300 Series is turned off.
If the 300 Series is in the process of completing an operation (user input, Hold
weight processing, report printing, etc.) and the off key is pressed, it will only
turn off once the operation has been completed.
1. From the Normal Operating mode
press the OFF key.
2. The 300 Series turns off.

Series 300 User Manual13
Copyright © 2021, Reliable Scale Corporation
3 Configuration Menus
The 300 Series uses a system of menus to organize its various operating
parameters. There are four main menus, each with a number of sub-menus. The
menus are navigated using the arrow keys and wrap back to the top when the end
of the current list is reached. Pressing ENTER selects the current menu item or
steps into the next menu level. Pressing EXIT cancels the current operation or
steps out of the current sub-menu.
Note: Be sure to read and fullyunderstand the directions before making any
modifications to the 300 Series configuration. Failure to do so mayrender the 300
Series inoperable for your application.
1. To access the configuration
menus, press MENU.
2. Use UP and DOWN to move the
cursor up or down to the sub-
menu.
Report sub-menus are used to
collect, report and manage
Weight Record collection
(including RFID if installed).
User Interface sub-menus are
used to set the operator
interface.
Auto-Hold sub-menus are used
to set the automatic average and
hold feature operating
parameters.
System Setup sub-menus are
used to set the data acquisition
operating parameters.

Configuration Menus 14
Copyright © 2021, Reliable Scale Corporation
3. To return to the Normal
Operating mode, press the
EXIT key to back out of each
menu level.
3.1 Report Menu
The Report menu controls the collection, reporting and management of Weight
Records (including RFID if installed).
1. From the Main menu select the
Report menu and press
ENTER.
2. Using UP and DOWN, navigate
to the sub-menu.
Display stored Record Totals.
Send a Basic Report.
Send a Detailed Report.
Set Current Lot for record
storage.

Series 300 User Manual15
Copyright © 2021, Reliable Scale Corporation
Clear Current Lot records.
Clear All Records.
Check Free Records.
Set the RFID Configuration.
Note: The RFID Configuration
menu is onlypresent in 'X' variations of
the 300 Series devices.
3. To return to a previous menu
level, press the EXIT key to
back out of each menu level.
3.1.1 Record Totals
A summary of the Weight Record Totals for each Lot can be displayed by the
Series 300 device. The summary includes the number of records in the Lot as
well as the total, average, maximum and minimum weights for that Lot.
Note: If the current lot is set to zero, the summaryincludes data from allLots.
1. From the Record Totals menu,
press ENTER.
If Lots are enabled, a prompt for
the Lot to summarize is displayed.

Series 300 User Manual17
Copyright © 2021, Reliable Scale Corporation
The maximum recorded weight is
displayed.
The minimum recorded weight is
displayed.
3. Anytime while the summary is
being displayed, press ENTER to
choose another Lot, or press
EXIT to return to the Report
menu.
3.1.2 Basic Report
The Basic Report is used to send a basic summary of the Weight Record Totals
for a specified Lot to an external device (PC, Printer, etc.) via the Serial Port.
Note: Any Serial Port that is configured to send reports will send the Basic Report.
Note: Time stamp informationis onlyincluded in'X' variations of the 300 Series
devices.
1. From the Basic Report menu,
press ENTER.
This manual suits for next models
6
Table of contents