resideo 269SN Assembly instructions

Other resideo Switch manuals

resideo ZW4008 User manual

resideo

resideo ZW4008 User manual

resideo Braukmann DDS76 User manual

resideo

resideo Braukmann DDS76 User manual

resideo 5869 User manual

resideo

resideo 5869 User manual

Popular Switch manuals by other brands

TRENDnet TK-401R null

TRENDnet

TRENDnet TK-401R null

TRENDnet TK-200K null

TRENDnet

TRENDnet TK-200K null

TRENDnet TE100-S8 null

TRENDnet

TRENDnet TE100-S8 null

URC Total Control MFS-8 installation manual

URC

URC Total Control MFS-8 installation manual

Azbil HPQ-D11 user manual

Azbil

Azbil HPQ-D11 user manual

Sony DFS-900M operating instructions

Sony

Sony DFS-900M operating instructions

SICK i17S operating instructions

SICK

SICK i17S operating instructions

F&F SZR-277 quick start guide

F&F

F&F SZR-277 quick start guide

Shure UAMS/BK user guide

Shure

Shure UAMS/BK user guide

Dräger X-zone Switch Off Instructions for use

Dräger

Dräger X-zone Switch Off Instructions for use

Asco Joucomatic 349 Series manual

Asco

Asco Joucomatic 349 Series manual

BT Mini Hub user guide

BT

BT Mini Hub user guide

D-Link DES-1226G manual

D-Link

D-Link DES-1226G manual

Johnson Controls FS80-C installation instructions

Johnson Controls

Johnson Controls FS80-C installation instructions

MicroNet SP1200A user manual

MicroNet

MicroNet SP1200A user manual

Ruijie RG-PF2920 Series Hardware  installation and reference guide

Ruijie

Ruijie RG-PF2920 Series Hardware installation and reference guide

Altinex DA1914SX user guide

Altinex

Altinex DA1914SX user guide

RJM MASTERMIND PBC/6X user manual

RJM

RJM MASTERMIND PBC/6X user manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

K0400V1D 4/03 Rev D
269SN
Holdup
Switch
Installation and Setup Guide
GENERAL INFORMATION
The 269SN Holdup Switch (Figure 1) is a finger-operated 2-wire
V- lex® polling loop device with point identification. The Holdup
Switch is typically mounted under a counter for inconspicuous
operation. When the switch is activated, the control panel sends a
burglary alarm to the central station. The device comes standard
as a latching type switch that is easily converted to a non-latching
type.
If the switch is used as a latching type switch, the supplied reset
key is used to reset the device. Additional reset keys may be
obtained separately by ordering ADEMCO part number K4563V1.
SUPERVISION
While the system is armed, tamper/supervisory faults will report
as alarms. While the system is disarmed, tamper/supervisory will
always report as troubles.
PROGRAMMING
Refer to the Security System Control anel Installation and Setup
Guide for specific programming instructions.
rogram the unit like any other zone, according to the alarm
controlÊs installation and setup guide. Enter the following
information when prompted for in zone programming:
„ZONE TY E‰ = „06‰ (24-HR Silent)
„IN UT TY E‰ = „06‰ (SL – Serial Number olling Loop Device)
MOUNTING
Refer to the steps and figures that follow for typical mounting
installation.
1. If required, convert the latching device to a non-latching
device as shown in Figure 2.
2. Run the wiring from the control panel to the device, through
the opening in the case back as shown in Figure 3.
3. Wire the device as shown in Figure 4, observing correct
polarity.
IM ORTANT!
IM ORTANT! IM ORTANT!
IM ORTANT! If the switch (or any other V- lex® polling
loop device) is located outside the building, you must use
either shielded twisted-pair cable, or run the wiring in metal
conduit. In either case, terminate the shield or conduit to
earth ground at the panel.
4. Secure the cover to the case with two screws (No. 6 x 7/8) as
shown in Figure 1. Be sure to use the correct holes. The holes
opposite these are used to secure the device to the counter.
IM ORTANT:
IM ORTANT: IM ORTANT:
IM ORTANT: To prevent damage to the case, do not over
tighten the cover screws.
5. eel the backing from the double stick tape strips on the
back of the device and position the device in its mounting
location.
IM ORTANT:
IM ORTANT: IM ORTANT:
IM ORTANT: The double stick tape is provided to
temporarily hold the assembly in place while drilling the
pilot holes. The device must be permanently mounted with
the screws supplied.
6. Using the case as a drill template, drill a 1/16‰ diameter pilot
hole at the two case mounting holes (Figure 5).
7. Secure the assembled case with the protective cover to the
counter with two screws (No. 6 x 1-3/4) supplied (Figure 5).
Figure 1
Figure 2
+
+
MOUNTING
HOLE
TRIGGER
RESET KEY
(K4563
SUPPLIED)
COVER
SCREW
(2)
No. 6x7/8
PROTECTIVE
STEEL
COVER
CIRCUIT
BOARD
COVER 
ATTACH HOLE
COVER
ATTACH 
HOLE
MOUNTING
SCREW
(2)
No. 6X1 3/4
COVER
SCREW
COVER
269SN-001-V1
MOUNTING
HOLE
TRIGGER
ASSEMBLY
TO CONVERT TO MOMENTARY (NO LATCHING) SWITCH
OPERATION, REMOVE THE TRIGGER ASSEMBLY FROM THE
CASE. USING A PAIR OF CUTTERS, CUT THE TRIGGER LATCH
AT THE POINT THE "ARROW" IS STAMPED ON THE CASE.
TRIGGER
LATCH
ARROW
(CUT POINT)
269SN-003-V0
Figure 3
Figure 4
Figure 5
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by
the installer and frequent testing by the user are vital to
continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing
and offering a regular maintenance program to the user, as well
as acquainting the user with the proper operation and
limitations of the alarm system and its component parts.
Recommendations must be included for a specific program of
frequent testing (at least weekly) to ensure the system's
operation at all times.
WARRANTY INFORMATION
For the latest warranty information, please go to:
www.resideo.com
SPECIFICATIONS
hysical
hysicalhysical
hysical
2"W x 3-1/2"H x 1/4"D
(51mm x 89mm x 32mm)
Electrical
ElectricalElectrical
Electrical
Multiplex Supply 1.0mA, MAX Current:
::
:
Operating
OperatingOperating
Operating
32°F to 122°F
Temperature:
Temperature:Temperature:
Temperature:
0°C to 50°C
Agency:
Agency:Agency:
Agency:
UL 636 – Holdup alarm units and
systems
Reset
ResetReset
Reset
Key:
Key:Key:
Key:
Supplied, art Number K4563 to
order separately
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
© 2020 Resideo Technologies, Inc.
www.resideo.com
K0400V1D 4/03 Rev D
ROUTE THE WIRE THROUGH THE WIRE ENTRY HOLE.
STRIP 6MM (.24 INCH) OFF THE WIRE ENDS.
269SN-004-V0
TERM. ASSIGNMENT
269SN-002-V0
POLLING LOOP
TERMINALS ON
CONTROL
1 (+) POLLING LOOP (+)
2 ( ) POLLING LOOP ( )
POLLING LOOP
ALWAYS OBSERVE POLARITY.
ALWAYS CONNECT IN PARALLEL.
MOUNTING
SCREW (2)
No. 6X1 3/4
(SUPPLIED)
269SN-009-V1
MOUNTING
HOLE
MOUNTING
HOLE
IMPORTANT:
THIS DEVICE MUST
BE PERMANENTLY
MOUNTED WITH THE 
SCREWS SUPPLIED
HOLDUP SWITCH SHOWN MOUNTED
IN TYPICAL UNDER COUNTER APPLICATION
C
US
US
R