manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. resideo
  6. •
  7. Switch
  8. •
  9. resideo 269SN Assembly instructions

resideo 269SN Assembly instructions

K0400V1D 4/03 Rev D
269SN
Holdup
Switch
Installation and Setup Guide
GENERAL INFORMATION
The 269SN Holdup Switch (Figure 1) is a finger-operated 2-wire
V- lex® polling loop device with point identification. The Holdup
Switch is typically mounted under a counter for inconspicuous
operation. When the switch is activated, the control panel sends a
burglary alarm to the central station. The device comes standard
as a latching type switch that is easily converted to a non-latching
type.
If the switch is used as a latching type switch, the supplied reset
key is used to reset the device. Additional reset keys may be
obtained separately by ordering ADEMCO part number K4563V1.
SUPERVISION
While the system is armed, tamper/supervisory faults will report
as alarms. While the system is disarmed, tamper/supervisory will
always report as troubles.
PROGRAMMING
Refer to the Security System Control anel Installation and Setup
Guide for specific programming instructions.
rogram the unit like any other zone, according to the alarm
controlÊs installation and setup guide. Enter the following
information when prompted for in zone programming:
„ZONE TY E‰ = „06‰ (24-HR Silent)
„IN UT TY E‰ = „06‰ (SL – Serial Number olling Loop Device)
MOUNTING
Refer to the steps and figures that follow for typical mounting
installation.
1. If required, convert the latching device to a non-latching
device as shown in Figure 2.
2. Run the wiring from the control panel to the device, through
the opening in the case back as shown in Figure 3.
3. Wire the device as shown in Figure 4, observing correct
polarity.
IM ORTANT!
IM ORTANT! IM ORTANT!
IM ORTANT! If the switch (or any other V- lex® polling
loop device) is located outside the building, you must use
either shielded twisted-pair cable, or run the wiring in metal
conduit. In either case, terminate the shield or conduit to
earth ground at the panel.
4. Secure the cover to the case with two screws (No. 6 x 7/8) as
shown in Figure 1. Be sure to use the correct holes. The holes
opposite these are used to secure the device to the counter.
IM ORTANT:
IM ORTANT: IM ORTANT:
IM ORTANT: To prevent damage to the case, do not over
tighten the cover screws.
5. eel the backing from the double stick tape strips on the
back of the device and position the device in its mounting
location.
IM ORTANT:
IM ORTANT: IM ORTANT:
IM ORTANT: The double stick tape is provided to
temporarily hold the assembly in place while drilling the
pilot holes. The device must be permanently mounted with
the screws supplied.
6. Using the case as a drill template, drill a 1/16‰ diameter pilot
hole at the two case mounting holes (Figure 5).
7. Secure the assembled case with the protective cover to the
counter with two screws (No. 6 x 1-3/4) supplied (Figure 5).
Figure 1
Figure 2
+
+
MOUNTING
HOLE
TRIGGER
RESET KEY
(K4563
SUPPLIED)
COVER
SCREW
(2)
No. 6x7/8
PROTECTIVE
STEEL
COVER
CIRCUIT
BOARD
COVER 
ATTACH HOLE
COVER
ATTACH 
HOLE
MOUNTING
SCREW
(2)
No. 6X1 3/4
COVER
SCREW
COVER
269SN-001-V1
MOUNTING
HOLE
TRIGGER
ASSEMBLY
TO CONVERT TO MOMENTARY (NO LATCHING) SWITCH
OPERATION, REMOVE THE TRIGGER ASSEMBLY FROM THE
CASE. USING A PAIR OF CUTTERS, CUT THE TRIGGER LATCH
AT THE POINT THE "ARROW" IS STAMPED ON THE CASE.
TRIGGER
LATCH
ARROW
(CUT POINT)
269SN-003-V0
Figure 3
Figure 4
Figure 5
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by
the installer and frequent testing by the user are vital to
continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing
and offering a regular maintenance program to the user, as well
as acquainting the user with the proper operation and
limitations of the alarm system and its component parts.
Recommendations must be included for a specific program of
frequent testing (at least weekly) to ensure the system's
operation at all times.
WARRANTY INFORMATION
For the latest warranty information, please go to:
www.resideo.com
SPECIFICATIONS
hysical
hysicalhysical
hysical
2"W x 3-1/2"H x 1/4"D
(51mm x 89mm x 32mm)
Electrical
ElectricalElectrical
Electrical
Multiplex Supply 1.0mA, MAX Current:
::
:
Operating
OperatingOperating
Operating
32°F to 122°F
Temperature:
Temperature:Temperature:
Temperature:
0°C to 50°C
Agency:
Agency:Agency:
Agency:
UL 636 – Holdup alarm units and
systems
Reset
ResetReset
Reset
Key:
Key:Key:
Key:
Supplied, art Number K4563 to
order separately
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
© 2020 Resideo Technologies, Inc.
www.resideo.com
K0400V1D 4/03 Rev D
ROUTE THE WIRE THROUGH THE WIRE ENTRY HOLE.
STRIP 6MM (.24 INCH) OFF THE WIRE ENDS.
269SN-004-V0
TERM. ASSIGNMENT
269SN-002-V0
POLLING LOOP
TERMINALS ON
CONTROL
1 (+) POLLING LOOP (+)
2 ( ) POLLING LOOP ( )
POLLING LOOP
ALWAYS OBSERVE POLARITY.
ALWAYS CONNECT IN PARALLEL.
MOUNTING
SCREW (2)
No. 6X1 3/4
(SUPPLIED)
269SN-009-V1
MOUNTING
HOLE
MOUNTING
HOLE
IMPORTANT:
THIS DEVICE MUST
BE PERMANENTLY
MOUNTED WITH THE 
SCREWS SUPPLIED
HOLDUP SWITCH SHOWN MOUNTED
IN TYPICAL UNDER COUNTER APPLICATION
C
US
US
R
LISTED

Other resideo Switch manuals

resideo ZW4008 User manual

resideo

resideo ZW4008 User manual

resideo Braukmann DDS76 User manual

resideo

resideo Braukmann DDS76 User manual

resideo 5869 User manual

resideo

resideo 5869 User manual

Popular Switch manuals by other brands

D-Link DES-1008D manual

D-Link

D-Link DES-1008D manual

HP ProCurve 10/100 12 installation guide

HP

HP ProCurve 10/100 12 installation guide

Ihse Draco Tera Compact Quick setup

Ihse

Ihse Draco Tera Compact Quick setup

HWM Wi5 user manual

HWM

HWM Wi5 user manual

HP 6125G Command reference

HP

HP 6125G Command reference

NKK SWITCHES FF01 Series quick start guide

NKK SWITCHES

NKK SWITCHES FF01 Series quick start guide

H3C S7500-LSQM1SRPB0-SALIENCE VI FRU PRE REL installation manual

H3C

H3C S7500-LSQM1SRPB0-SALIENCE VI FRU PRE REL installation manual

D-Link GO-SW-5G Quick installation guide

D-Link

D-Link GO-SW-5G Quick installation guide

Endress+Hauser Liquiphant FTL51B operating instructions

Endress+Hauser

Endress+Hauser Liquiphant FTL51B operating instructions

Siemens CSM 1277 operating instructions

Siemens

Siemens CSM 1277 operating instructions

Gefen VGA-142N user manual

Gefen

Gefen VGA-142N user manual

H3C S9500 Series Operation manual

H3C

H3C S9500 Series Operation manual

ATEN UC2322 user manual

ATEN

ATEN UC2322 user manual

XTBA Smart Switch 8:4 manual

XTBA

XTBA Smart Switch 8:4 manual

HPE Aruba 6300M Product End-of-Life Disassembly Instructions

HPE

HPE Aruba 6300M Product End-of-Life Disassembly Instructions

GRASS VALLEY Zodiak Digital Production Switcher user manual

GRASS VALLEY

GRASS VALLEY Zodiak Digital Production Switcher user manual

LEGRAND In One 916 29 manual

LEGRAND

LEGRAND In One 916 29 manual

Panasonic AH1 quick start guide

Panasonic

Panasonic AH1 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.