manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Resolution Products
  6. •
  7. Security Sensor
  8. •
  9. Resolution Products RE219 User manual

Resolution Products RE219 User manual

RE219_Honeywell_Flood_Temp_Instructions.docPage 1 of 9/6/2011
www.ResolutionProducts.com
Wireless
Security
Solutions
RE219 House Disaster: Flood/Temp Range,
Honey ell-Compatible
Features
•Tri-Mode Environmental Sensing:
oFlood/Moisture Sensor
oFreeze – for Furnace Failure
oOverheat – for Furnace runaway or Air Conditioning failure.
•3 unique wireless Loops: one for each function
•Cover tamper.
•Strong, reliable RF signal.
•8-10 year battery life on CR123A battery.
•Low Battery indication.
•3.3x1. x1.1 inches.
Key Instructions
•Battery “+” faces towards spring.
•Enrolling:
Place Panel in Zone Programming mode.
Zone Type = for example, 2 -Hr. Aux.
Input Type = Supervised RF Transmitter.
When asked for serial number, press Tamper switch.
Program the desired Loop number you want that zone to
monitor. Loop functions are:
•Loop 1: Overheat.
•Loop 2: Flood.
•Loop 3: Freeze.
•Loop : Tamper.
•Test Temp alarm functions by putting in a freezer, or blowing a hair dryer on
sensor.
•Test Flood alarm function by putting sensor in water (distilled water will not
work, but tap water should).
RE219_Honeywell_Flood_Temp_Instructions.docPage 2 of 9/6/2011
www.ResolutionProducts.com
Operation
•Flood – Loop 2:
Alarm: when liquid rises 0.0 0 inches above sensor bottom.
Tamper: when cover is opened.
Supervisory: every hour.
•Freeze – Loop 3
Alarm: when room temperature drops below 0F.
Tamper: when cover is opened.
Supervisory: every hour.
•Overheat – Loop 1
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened.
Supervisory: every hour.
RE219_Honeywell_Flood_Temp_Instructions.docPage 3 of 9/6/2011
www.ResolutionProducts.com
Specifications
Flood sensing: Titanium contacts
100K-Ohm nominal (DO NOT use an EOL resistor)
0.0 inch floor spacing to eliminate floor
condensation falses.
Checks moisture every 30 seconds
(test mode: every second when cover is off)
Freeze Alarm: 0F +/- 2F (custom temps available)
Restores when temp increases F from alarm
Overheat Alarm Temp: 100F +/- 2F (custom temps available)
Restores when temp decreases F from alarm
Mounting hardware: #6 or #8 screws
Dual Mode mounting:
Screwed to floor
Screwed to wall
Terminal wire capacity: 16 Gauge
Replacement Battery: CR123A 1550 mAH
Temperature Range: 0F to 120F
Housing dimensions: 3.3x1. x1.1 inches
Specifications subject to change without notice.
Internal & Close-up Pictures
Temp Element
Strain relief for
floor mounting
RE219_Honeywell_Flood_Temp_Instructions.docPage of 9/6/2011
www.ResolutionProducts.com
Notices
“GE”, “Honeywell”, and “DSC” are trademarks owned by General Electric Company, Honeywell
International Inc., and Tyco Safety Products Canada LTD, respectively.
Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems.
However, no Resolution product is produced by, endorsed by, nor is officially associated with GE,
Honeywell or DSC. Resolution recommends verifying proper enrollment and operation, per control
panel installation instructions, at installation.
Warranty
Resolution Products, Inc. will replace products that are defective in their first year.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the Resolution Products, Inc. could void
the user's authority to operate this equipment.
FCC ID: U5X-RE201X
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause
undesired operation of the device.
Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence. Son
fonctionnement est soumis aux deux conditions suivantes:
1. Ce dispositif ne peut causer des interférences, et
2. Ce dispositif doit accepter toute interférence, y compris les interférences qui
peuvent causer un mauvais fonctionnement du dispositif.
IC: 8310A-RE201

Other Resolution Products Security Sensor manuals

Resolution Products Mighty Mouse RE211 User manual

Resolution Products

Resolution Products Mighty Mouse RE211 User manual

Resolution Products RE353 User manual

Resolution Products

Resolution Products RE353 User manual

Resolution Products RE310P+ User manual

Resolution Products

Resolution Products RE310P+ User manual

Resolution Products Mighty Mouse RE111 User manual

Resolution Products

Resolution Products Mighty Mouse RE111 User manual

Resolution Products RE210P User manual

Resolution Products

Resolution Products RE210P User manual

Resolution Products RE110P+ User manual

Resolution Products

Resolution Products RE110P+ User manual

Resolution Products RE253 User manual

Resolution Products

Resolution Products RE253 User manual

Resolution Products RE200 User manual

Resolution Products

Resolution Products RE200 User manual

Popular Security Sensor manuals by other brands

D-tect Systems D-TECT GJD360/AM quick start guide

D-tect Systems

D-tect Systems D-TECT GJD360/AM quick start guide

DINUY DM K5X 001 manual

DINUY

DINUY DM K5X 001 manual

Bosch Photobeam 5000 Installation and operation guide

Bosch

Bosch Photobeam 5000 Installation and operation guide

DOL 104 4-20 mA Technical user guide

DOL

DOL 104 4-20 mA Technical user guide

Aritech 2X-A-LB Installation sheet

Aritech

Aritech 2X-A-LB Installation sheet

Filtec FT-50 Installation and setup guide

Filtec

Filtec FT-50 Installation and setup guide

S+S Regeltechnik KINASGARD RBWF-UP Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik KINASGARD RBWF-UP Operating Instructions, Mounting & Installation

Tractel HT Operating and maintenance instructions

Tractel

Tractel HT Operating and maintenance instructions

System Sensor B501BI-IV Installation and maintenance instructions

System Sensor

System Sensor B501BI-IV Installation and maintenance instructions

Powerfix Profi 97003 Operation and safety notes

Powerfix Profi

Powerfix Profi 97003 Operation and safety notes

Tecnar accuraspray CS Quick setup guide

Tecnar

Tecnar accuraspray CS Quick setup guide

Ludlum Measurements 44-9 manual

Ludlum Measurements

Ludlum Measurements 44-9 manual

Eurotops Versand 41582 instruction manual

Eurotops Versand

Eurotops Versand 41582 instruction manual

Siemens HI320C Description

Siemens

Siemens HI320C Description

Elgato eve door & window 20EAL9901 Get started

Elgato

Elgato eve door & window 20EAL9901 Get started

Aritech DD1012 Installation sheet

Aritech

Aritech DD1012 Installation sheet

ipf electronic OY36 Original instruction manual

ipf electronic

ipf electronic OY36 Original instruction manual

Optex QX Infinity Series installation instructions

Optex

Optex QX Infinity Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.