CFM 10 100 1,000 10,000
m3/hr 17 170 1,700 17,000
Open
A
C8
C6
C4
C2
B
Options for Model 1000
Frame extender kit
to 48” wide by 105” high
(requires large cloth). # AL215
Hard Sided Fan Case
works as equipment stand.
# FN211
Includes:
1. 1000 Fan Top, 2. Model 1000 calibrated fan, 3. Fan
Cover, 4. Fan Blade, 5. Range Plate A, 6. Range Plate B
7. Range Plate C, 8. Plug set, 9. 25 ft power cord,
10. Color coded tubing kit with Static Pressure Probe,
11. DM-2 digital gauge with NiMH rechargeable
batteries (charge in the gauge), 12. 6.5 ft umbilical,
13. USB cable, 14. Laptop-style gauge case,
15. Aluminum frame, 16. Single fan cloth, 17. Gun-style
case, 18. DoorFan QuickGuide, 19. DM-2 QuickGuide.
System Components
Double fan cloth.
# AL204
Upper Cross-bar
# AL112
Pressure Pans to
locate leakiest ducts.
# PT102 (large), # PT101 (small)
Wide span between the minimum/maximum ow, and seven included ranges, allow the leakiest and tightest buildings to be
tested. Calibration meets ASTM E779-10, EN 13829, CGSB 149.10, ATTMA TS-1, NFPA 2001. Flow is reduced by 15% for 50Hz.
www.retrotec.com Support:(604)732-0142 Sales:(855)738-7683 Made in Everson, WA USA
4 of 4
QuickGuide
The DM-2 has two independent differential-pressure
sensors (Channel A and B) and an automatic controller that
will control all Retrotec fans.
Channel A always displays the pressure difference between
the blue “Input A(+)” and the red “Ref A(-)”. “PrA” on the
screen refers to Pressure on channel A.
Channel B similarly measures pressure between “Input
B(+)” and “Ref B(-)”. This pressure is converted to ow or
other units when a Device and Mode is selected. See Page 4
to change the enabled Devices and Modes.
The DM-2 contains:
1―DM-2 Gauge
4 ― AA NiMH rechargeable Batteries
1 ― AC power adapter
1 ― Laptop-style case
1 ― Computer interface cable (mini-USB to USB)
1 ― Color coded set of tubes and connectors
1 ― Ethernet cable to connect to Device
● 4 AA NiMH rechargeable batteries are supplied.
● Install by removing the lower compartment cover on
the back of the DM-2.
● Fully charge the batteries on rst use, but avoid
prolonged charging.
● Press [On/Off] and the Retrotec screen shown
below appears.
Note: The DM-2 will not start charging unless it is
turned On.
● The batteries are fully charged when the indicator is
solid black.
● Non-rechargeable batteries can be used. To protect
the DM-2 from damage, press [Setup], scroll to
“Battery Type” and select “Rechargeable” or
“Not Rechargeable”. Press [Exit] to save selection.
Note: If “Not Rechargeable” is selected, no recharging
will occur.
Warning: Non rechargeable batteries may explode
if charged. Only charge rechargeable NiMH batteries.
Follow steps 1-15 to learn the basic gauge functions.
DM-2 mark II Digital Gauge
For the latest Retrotec documentation, visit us at: http://www.retrotec.com
Step 1: Batteries
QG100 rev-2011-04-04
Page 1of 4
www.retrotec.com Support:(604)732-0142 Sales: (855)738-7683 Madein Everson, WAUSA
QuickGuide
Door Fan (Blower Door)
Step 1: Prepare the building
□Close outside doors and windows.
□Open all interior doors leading to conditioned spaces.
□Turn gas, hot water, to Pilot.
□Fireplaces and stoves must be cold with doors
closed (cover ashes).
□Shut off HVAC, combustion appliances, exhaust fans,
dryers, A/C and furnaces.
See: Manual-Residential Pressure & Air LeakageTesting for
additional information.
□Set up the door panel.
See: DoorPanel-Cloth or DoorPanel-Modular QuickGuide
□Connect the yellow tube between yellow ports
marked “Ref B” on fan and DM-2. If the fan has a
green port (“Input B”), connect the green tube.
□ Connect the Speed Control Cable from fan to gauge.
Do not connect to the Internet.
□Pass long red tube through the Door Panel and toss
theend at least 5 feet away from the fan’s airstream.
Remove or cover
ashes.
Turn gas valve
to Pilot.
Close all windows
and outside doors. Place gauge case near fan, or attach gauge to Door Panel.
QG300 rev-2011-12-30
Page 1of 4
Note: Water in the tube will result in erroneous readings.
□Install the fan blowing outdoors. Cover fan.
□Connect the fan power plug to a wall outlet.
Model 1000
Device=”Retrotec1000”
Model 200
Device=“RetrotecDU200”
Model Q46, Q56
(Device= “Retrotec 2000”
Model Q4E, Q5E, QMG
(Device= “Retrotec3000SR)
www.retrotec.com Support:(604)732-0142 Sales: (855)738-7683 Made in Everson, WAUSA
Step 2: Install the system
Every system comes with
detailed QuickGuides
18. QG300
3. FN130
4. FN231
15. AL110
16. AL203
17. AL103
5. FN214
6. FN217
7. FN218
8. FN219
14. DM214
13. DM212
11. DM221 12. DM235
2. FN150
1. FN140
9. PT103
10. TU119
19. QG100
(Flow at 50 Pascals)