1.0 Introduction
The Altralite Floor Scale is a fully electronic, low profile load receiver. The Altralite Floor Scale is available in 4' x 4' (1.22 m x
1.22 m) with the capacity of 5K (2267.96 kg). The Altralite Floor Scale uses four corner-mounted, FM-approved load cells, with
the cells recessed into the frame channels for protection. A signal-trim summing board enclosed in a stainless steel, NEMA
Type 4X junction box is included for corner corrections.
All models come pre-trimmed. Corner corrections should not be necessary.
Load cell cables are enclosed in conduit through the main channels, and held down with replaceable cable ties near each
corner, eliminating the possibility of cable damage in portable applications. Also useful for portable applications are threaded
corner holes in the deck for removable eye bolts to allow lifting the scale from above with chains.
The possibility of foot and load cell damage from forklift tines, the scale should always be lifted from above with
chains through the eye bolts.
The adjustable feet are used to allow leveling the scale to make up for minor floor irregularities. For permanent installations, two
of the four feet can be held in place on the floor with optional floor mounting plates to guard against deck movement.
Other available options include custom frames for pit installations, and access ramps for all sizes and models of the Altralite
Floor Scale. Decks designed for use in pits can be ordered with holes drilled in the deck directly above each foot for adjusting
foot height with a screwdriver from above.
Manuals and additional resources are available from the Rice Lake Weighing Systems website at www.ricelake.com
Warranty information can be found on the website at www.ricelake.com/warranties
1.1 Safety
Safety Signal Definitions:
Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. Includes
hazards that are exposed when guards are removed.
Indicates a potentially hazardous situation that, if not avoided, could result in serious injury or death. Includes
hazards that are exposed when guards are removed.
Indicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury.
Indicates information about procedures that, if not observed, could result in damage to equipment or corruption
to and loss of data.
General Safety
Do not operate or work on this equipment unless this manual has been read and all instructions are understood.
Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice Lake
Weighing Systems dealer for replacement manuals.
Failure to heed could result in serious injury or death.
Do not allow minors (children) or inexperienced persons to operate this unit.
Do not operate without all shields and guards in place.
Do not jump on the scale.
Do not use for purposes other then weight taking.
Do not place fingers into slots or possible pinch points.
Do not use any load bearing component that is worn beyond 5% of the original dimension.
Do not use this product if any of the components are cracked.
Do not exceed the rated load limit of the unit.
Do not make alterations or modifications to the unit.
Do not remove or obscure warning labels.
Do not use near water.
Before opening the unit, ensure the power cord is disconnected from the outlet.
Keep hands, feet and loose clothing away from moving parts.