Model 14-RK10
QUICK START GUIDE
1 2
WARNING

5
7
3 4
Pull away and down on unit to
release mounting plate hook
from unit groove (circled).
Slip mounting plate hook
(circled) into unit groove before
pressing unit into place.
6
Place unit on a sturdy surface
to make this step easier.
IMPORTANT!
This unit is IP44-rated and has
some protection from the
elements, but it should be
mounted in a covered location.
Make sure to mount the unit
away from metal objects and
anything that will interfere
with or block RF transmission.
Unpack box and make sure you have all items shown here.
(Screwdriver not shown.)
Remove single screw from bottom of
unit and remove unit from mounting
plate, pulling away from bottom end.
AUTOMATIC GATES AND DOORS CAN CAUSE
SERIOUS INJURY OR DEATH!
ALWAYS CHECK THAT THE GATE/DOOR PATH
IS CLEAR BEFORE OPERATING!
REVERSING OR OTHER SAFETY DEVICES
SHOULD ALWAYS BE USED!
Replace back cover of unit and secure
with screws.
Attach unit and secure with screw.
(Can be done after programming.)
Remove screws from back of unit
housing and carefully remove back
cover to get access to battery holders.
Hold circuit board in place and insert
batteries into battery holders, making
sure to place in correct orientation.
Ridge ResKey
Unit
AAA Battery
( 2x )
Install mounting plate where desired
(hardware not included).
(Can be done after programming.)
Receiver
(Security Brands 14-REC20
or 14-REC300 not included)
www.ShopAmericanAccess.com | (800) 878-7829 | [email protected]
2 of 2
Model 14-RK10
QUICK START GUIDE
A B
433-MHz Programming
(For the Ridge 2.0 Transceiver 14-REC20 only)
300-MHz Programming
(For 300-MHz receivers including the Receiver 300 14-REC300)
IMPORTANT! For security reasons we recommend using custom DIP switch positions.
11 12 5 _ _ _ _
Access Code to Be Added
(4 digits; numbers only)
Master Code
(1251 is default)
Channel
(1 for A, 7 for B)
Add 433-MHz Access Code
Pair Keypad Unit with Ridge 2.0 Receiver (14-REC20)
On Ridge 2.0 Transceiver, press and hold programming button for two seconds and let go.
LED will light. Perform procedure below, and LED will go out if pairing is successful.
21 12 5 _ _ _ _
Access Code to Be Deleted
(4 digits; numbers only)
Master Code
(1251 is default)
Sub Mode
Sub Mode
Delete 433-MHz Access Code
31 12 5 _ _ _ _
New Master Code
(4 digits; numbers only)
Master Code
(1251 is default)
Sub Mode
Change 433-MHz Master Code
81 12 5 _ _ _ _
Code to Be Added
(4 digits; numbers only)
Master Code
(1251 is default)
Sub Mode
Add 433-MHz Limited-Use Code (Channel A Only)
_
# of Uses
(1–9)
01 12 5 1 12 5
Master Code Again
(1251 is default)
Unit will beep and flash
and sound good tone
when complete.
Master Code
(1251 is default)
Sub Mode
Delete All 433-MHz Codes
91 12 5 _
Master Code
(1251 is default)
Channel
(1 for A, 2 for B)
Signifies a good tone
Signifies a good tone
_ _ _ _
_
Access Code to Be Added
(4 digits; numbers only)
19 99 9
Master Code
(9999 is default)
Receiver DIP Switch Positions
(0 for off, 1 for on; 0101010101 is default)
Sub Mode
Add 300-MHz Access Code
2_ _ _ _
Access Code to Be Deleted
(4 digits; numbers only)
Sub Mode
Delete 300-MHz Access Code
3_ _ _ _
New Master Code
(4 digits; numbers only)
Sub Mode
Change 300-MHz Master Code
0
Master Code Again
(9999 is default)
Unit will beep and flash
and sound good tone
when complete.
Sub Mode
Delete All 300-MHz Codes
9 99 9
Master Code
(9999 is default)
9 99 9
Master Code
(9999 is default)
9 99 9 9 99 9
Master Code
(9999 is default)
_________
www.ShopAmericanAccess.com | (800) 878-7829 | [email protected]

Popular Keypad manuals by other brands

URC TKP-7600 owner's manual

URC

URC TKP-7600 owner's manual

SECO-LARM Enforcer SK-1323-SDQ Quick user programming guide

SECO-LARM

SECO-LARM Enforcer SK-1323-SDQ Quick user programming guide

Hills NX-1508 user manual

Hills

Hills NX-1508 user manual

Crow OLED user guide

Crow

Crow OLED user guide

Renishaw Equator EQ-BI quick start guide

Renishaw

Renishaw Equator EQ-BI quick start guide

ACT ACT10 DIGITAL KEYPAD Installation notes

ACT

ACT ACT10 DIGITAL KEYPAD Installation notes

xpr MTPAD - M manual

xpr

xpr MTPAD - M manual

Ortek WKP-7110BT user manual

Ortek

Ortek WKP-7110BT user manual

FM Electronics 4180 quick start guide

FM Electronics

FM Electronics 4180 quick start guide

NAPCO RP1054e installation instructions

NAPCO

NAPCO RP1054e installation instructions

DSC LCD5501Z instruction manual

DSC

DSC LCD5501Z instruction manual

Ness M1 Navigator user manual

Ness

Ness M1 Navigator user manual

Honeywell 6271C - Ademco TouchCenter Color Keypad user guide

Honeywell

Honeywell 6271C - Ademco TouchCenter Color Keypad user guide

Elite Suite ELT-KLED installation manual

Elite Suite

Elite Suite ELT-KLED installation manual

First Alert 1220CV quick guide

First Alert

First Alert 1220CV quick guide

A-Neuvideo ANI-8WP instruction manual

A-Neuvideo

A-Neuvideo ANI-8WP instruction manual

POSIFLEX KB-4000 user manual

POSIFLEX

POSIFLEX KB-4000 user manual

Gemini GEM-RP8 operating guide

Gemini

Gemini GEM-RP8 operating guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.