Rigel 288+
1LCD screen
2Function keys F1 - F4
3Directional arrow keys
4OFF/Stop key
5ON/Start key
6Alphanumeric keyboard
7DUT socket
Getting to know your Rigel 288+ 2Unique use of icons
3Getting started
In this section we will identify some of the basic functions of the Rigel 2 + and how to get
you started.
Perform electrical safety tests
The Rigel 2 + features a high resolution graphic backlit display which not only provides
highly visible and easy to follow menu structures but also allows the user to operate the
tester and the intuitive icons speed up test routines.
Rigel 288+ icon key
Rear Connection Panel
810-way patient Applied Part adaptor
box connection
9Mains power connections
RS-232 lead socket
Auxiliary earth bond socket
IEC lead test socket
Earth bond probe socket
10 way Applied Part Adaptor box
Switch on
Turn on your Rigel 2 + by pressing and holding
the green ON button until you hear a ‘beep’ and
the Rigel splash screen appears
Instruction manual
Instruction Manual
This Quick Guide is designed to be used in
conjunction with the full Rigel 2 + Instruction
Manual.
The Rigel 2 + Electrical Safety Analyser Instruction
manual is available as a download from
rigelmedical.com/rigel-downloads
The download section also includes a free 30 day
trial for our asset management software, Med-eBase
Launch a test in Automatic Mode
Ensure Equipment Under Test (EUT) is plugged into DUT socket and any applied parts are
connected to the Applied Part module.
Select for the main menu and choose Auto Mode
Enter the Asset ID then choose the test standard and whether to run the test in semi or
automatic mode.
Select for the applied parts setup and to edit.
For safety reasons, the Applied Part configuration will revert to 10 CF after the unit has been
switched off.
Re-launch a previously
saved test
Ensure EUT is plugged into DUT
socket and any applied parts are
connected to the Applied Part
Module.
Select for the main menu and
then choose Auto Mode
Enter the Asset ID of the EUT and
press F4 to confirm you want to
reload existing test data.
Warnings during testing
To ensure the measurements are
performed under valid and consistent
conditions, the Rigel 2 + performs a
number of self-checks upon power up
and prior to a powered safety test
(leakage test). A warning message
may appear if these conditions are not
met.
In addition, the Rigel 2 + is able to
check for a valid test setup for
measurements done using the direct
method. In case a secondary earth
path is detected, the Rigel 2 + will
warn the user. It is not possible to
continue as testing under such
conditions will always result in a “zero”
reading due to the low Ohm
resistance of the secondary earth
path in comparison to the 1kOhm
resistance of the body model used in
the Rigel 2 +.